510(k) Data Aggregation

    K Number
    K112301

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-01-06

    (149 days)

    Product Code
    Regulation Number
    888.3520
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K033363,K110415,K093533

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Zimmer Patient Specific Instruments System is intended to be used as a surgical instrument to assist in the positioning of Unicompartmental Knee Replacement components intra-operatively and in guiding the marking of bone before cutting and to guide cutting of the bone provided that anatomic landmarks necessary for alignment and positioning of the implant are identifiable on patient imaging scans.

    The Zimmer Patient Specific Instruments System is to be used with Zimmer Unicompartmental High Flex Knee System prostheses families only.

    The Zimmer Patient Specific Instruments are intended for single use only.

    Device Description

    The Zimmer Patient Specific Instruments System consists of a software component, Zimmer Patient Specific Instruments Planner and a hardware component, Zimmer Patient Specific Instruments and is designed to assist the surgeon in the placement of unicompartmental knee replacement components for Unicompartmental High Flex Knee System prosthesis.

    AI/ML Overview

    The provided text describes a 510(k) summary for the Zimmer Patient Specific Instruments System, outlining its intended use, technological characteristics, and performance data. However, it does not contain specific acceptance criteria with numerical targets, nor does it detail a study that explicitly proves the device meets such criteria in a quantitative manner as typically requested for AI/ML device evaluations.

    Instead, the performance data section generally states that "Software validation and accuracy performance testing by means of saw bone models, cadaveric trials and guide deformation verification after sterilization were performed to assess the safety and effectiveness of the device." And "These tests verified that the accuracy and performance of the device is adequate to perform as intended."

    This suggests a general validation rather than a study with defined acceptance criteria and corresponding quantitative results. The submission predates modern requirements that would typically necessitate detailed quantitative performance metrics for AI/ML components.

    Given the information provided, I cannot populate the table or answer all requested questions with specific quantitative details. I will indicate where the information is not available in the provided text.

    Here's an attempt to answer the questions based on the available text:


    1. A table of acceptance criteria and the reported device performance

    No specific numerical acceptance criteria or quantitative performance metrics are provided in the document. The performance data section broadly states: "These tests verified that the accuracy and performance of the device is adequate to perform as intended."

    Acceptance CriteriaReported Device Performance
    Not specified in detail (e.g., target accuracy, precision)"Accuracy and performance of the device is adequate to perform as intended" based on software validation, saw bone models, cadaveric trials, and guide deformation verification after sterilization. (Specific numerical results are not provided).

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    The text mentions "saw bone models" and "cadaveric trials" as part of non-clinical tests.

    • Sample size: Not specified.
    • Data provenance: "Saw bone models" and "cadaveric trials" imply laboratory-based testing, not clinical data from patients. The country of origin for this testing is not specified. It is inherently prospective in the context of the testing (i.e., conducted specifically for the submission).

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    Not applicable. The performance testing described (saw bone models, cadaveric trials, guide deformation) does not involve expert-established ground truth in the context of diagnostic interpretation or clinical decision-making. It's a physical or software accuracy validation.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    Not applicable. This device is not an AI/ML diagnostic interpretation system that would typically require expert adjudication for ground truth. The validation relies on measurements from physical models and cadavers.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No. An MRMC study is not mentioned. The device assists surgeons in positioning knee replacement components and guiding cuts, rather than providing interpretations for human readers to evaluate.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    The device explicitly includes a "human-in-the-loop" step: "The software is then used pre-operatively by a qualified surgeon to inspect, fine-tune and approve the pre-surgical plan." Therefore, a standalone (algorithm only) performance, separate from the surgeon's review and approval, is not described or indicated as being evaluated as such. The system is designed to be used with a surgeon's oversight.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    For the non-clinical tests:

    • For software validation and accuracy testing: Likely engineering specifications, direct measurements on saw bone models or cadavers (e.g., comparing planned cuts/positions to actual cuts/positions, or anatomical landmarks), and measurements related to guide deformation.
    • The text states "These tests verified that the accuracy and performance of the device is adequate to perform as intended," implying comparison against an established engineering or anatomical ground truth, even if not explicitly detailed.

    8. The sample size for the training set

    Not applicable. The description does not indicate an Artificial Intelligence/Machine Learning (AI/ML) component that would typically require a "training set" in the modern sense. The "Zimmer Patient Specific Instruments Planner" is described as a "software component" that "generates a pre-surgical plan based on MRI imaging data." This sounds like rule-based software or traditional image processing, not a machine learning model that undergoes a distinct training phase.

    9. How the ground truth for the training set was established

    Not applicable, as there is no indication of an AI/ML component requiring a training set with established ground truth in the context of machine learning.

    Ask a Question

    Ask a specific question about this device

    K Number
    K102795

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-02-02

    (128 days)

    Product Code
    Regulation Number
    888.3560
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K073449, K093533

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Signature™ Personalized Patient Care System is intended to be used as a surgical instrument to assist in the positioning of total knee replacement components intra-operatively and in guiding the marking of bone before cutting provided that anatomic landmarks necessary for alignment and positioning of the implant are identifiable on patient imaging scans.

    The Signature™ Personalized Patient Care System can be used with the following Biomet knee systems and their respective components: Vanguard® Complete Knee System, Vanguard® SSK 360, Vanguard® SSK Revision Knee System, Regenerex® Primary Tibial System, Offset & Microplasty Tibial Systems, Maxim® Complete Knee System, Ascent™ Total Knee System, and AGC® Complete Knee system.

    The Signature™ guides are intended for single use only.

    Device Description

    Signature тм Personalized Patient Care System consists of a software component, Signature™ Planner and a hardware component, Signature™ guides and is designed to assist the surgeon in the placement of total knee replacement components.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and the study that proves the device meets them:

    1. Table of Acceptance Criteria and Reported Device Performance

    The provided 510(k) summary does not explicitly state specific numerical acceptance criteria for the device's performance. Instead, it refers to validation against intended use and substantial equivalence to predicate devices. The performance is broadly stated as "adequate."

    Acceptance Criteria (Implied)Reported Device Performance
    Accuracy performance adequate for intended use (e.g., precise pin placement for total knee replacement components)."Testing verified that the accuracy and performance of the system is adequate to perform as intended."
    Guide deformation verification after sterilization adequate for intended use."guide deformation verification after sterilization was performed to determine substantial equivalence."
    Substantial equivalence to predicate devices (SurgiCase K073449 and Zimmer Patient Specific Instruments System 2.0 K093533)."Device comparison showed that the proposed device is substantially equivalent to the predicate devices... Testing verified that the accuracy and performance of the system is adequate to perform as intended."

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Sample Size: The text states "cadaveric trials" were performed. However, it does not provide a specific number or range of cadavers used for these trials.
    • Data Provenance: The cadaveric trials imply a prospective data collection for the performance testing. The country of origin for the cadavers is not specified.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not mention the use of experts to establish ground truth for the CADAVERIC test set. The evaluation appears to be based on direct measurement of device output (e.g., pin placement accuracy). If human judgment was involved, it is not detailed.

    4. Adjudication Method for the Test Set

    As the document does not detail the use of experts or a subjective assessment for the test set's ground truth, an adjudication method is not described. The assessment seems to be based on objective measurement during the cadaveric trials.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    No, an MRMC comparative effectiveness study was not mentioned in this 510(k) summary. The device, Signature™ Planner, is a software for pre-surgical planning and the Signature™ guides are patient-specific templates. The focus is on the accuracy of these tools directly, not on improving human reader performance with AI assistance.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, in spirit. The "Signature™ Planner software... has been validated for its intended use" and "Accuracy performance testing by means of cadaveric trials" was performed. While a surgeon uses the software to "inspect, fine-tune and approve the pre-surgical plan," the performance testing described seems to primarily evaluate the system's (software + guides) ability to accurately transfer the plan to the physical space (cadaver) without explicitly measuring the impact of human fine-tuning on the accuracy results reported in the cadaveric trials. The accuracy reported ("adequate") is the outcome of the system's ability to produce precise pin locations.

    7. The Type of Ground Truth Used

    The ground truth for the cadaveric trials would likely be established through direct, precise measurement of the actual pin placements on the cadaveric bones relative to the intended pre-surgical plan. This would involve highly accurate measurement techniques (e.g., CMM, optical tracking, or high-resolution CT scans of the cadaver after pin insertion) to determine the deviation from the planned positions. This falls under objective physical measurement rather than expert consensus, pathology, or outcomes data.

    8. The Sample Size for the Training Set

    The document does not provide any information regarding a training set size. This is typical for medical device submissions focusing on predicate pathway and substantial equivalence, especially for technologies predating the widespread use of deep learning models that require large training datasets. The "Signature™ Planner" likely relies on established geometric algorithms and imaging processing techniques rather than a machine learning model that requires a distinct training phase with labeled data.

    9. How the Ground Truth for the Training Set Was Established

    As no training set is mentioned (see point 8), no information is provided on how its ground truth would have been established.