510(k) Data Aggregation

    K Number
    K212521

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-07-18

    (1073 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Rx

    Management of partial and full thickness wounds including stage I - IV pressure ulcers, ulcers caused by mixed vascular etiologies, Diabetic skin ulcers, 1st and 2nd degree burns, post-surgical incisions, graft sites, lacerations, skin tears, cuts and abrasions.

    OTC

    Management of minor wounds including minor cuts, abrasions, lacerations and burns.

    Device Description

    The Field Shield Wound Dressing is a spray on hydrogel wound dressing that hydrates, seals and protects dermal injuries to create and maintain a moist wound environment. A moist wound environment is known to be conducive to the wound healing process. It is a hydrophilic system containing a polyacrylate polymer matrix with silver hydrosol and lidocaine. The dressing donates moisture to a wound and maintains a moist environment. When applied to the liquid device donates moisture to the wound then sets into a thin, pliable, transparent film barrier over the surface of the wound. The film is capable of setting over intact and compromised skin surfaces. The device is intended for use for up to 30 days. with reapplication recommended every 24 to 72 hours. The device contains silver hydrosol that may inhibit the growth of microorganisms such as Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, antibiotic resistant strains of MRSA and VRE, as well as fungi such as Candida albicans and Candida auris within the dressing. Additionally, the dressing contains lidocaine as a topical anesthetic. Clinical evaluation showed that the Lidocaine can reduce pain within 30 minutes after application; long-term pain reduction has not been evaluated. Field Shield® Wound Dressing is intended for both Prescription and over the counter (OTC) indications for use.

    AI/ML Overview

    The provided document describes the KeriCure Inc.'s Field Shield Wound Dressing, an unclassified device. The information focuses on demonstrating its substantial equivalence to predicate devices, particularly regarding safety and effectiveness.

    Here's an analysis of the acceptance criteria and the study that proves the device meets them:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are not explicitly stated as quantitative thresholds for the Field Shield Wound Dressing. Instead, the document focuses on demonstrating that the device meets safety and performance standards equivalent to predicate devices, particularly through various types of testing. The reported device performance is outlined in the "Summary of Performance Testing" table.

    Test TypeAcceptance Criteria (Implied by "Passed")Reported Device Performance (Results)
    Clinical Study (Pain Relief)Significant reduction in painPain Relief provided within 30 minutes of application. The lidocaine within the device has a biological effect on the skin or wound, providing a significant reduction in pain to the treatment area when applied via spray within 30 minutes of application.
    Biocompatibility (Guinea Pig Maximization Sensitization Test)No sensitizationPassed (Score 0)
    Biocompatibility (Irritation Test)No irritationPassed (Score 0)
    Biocompatibility (Acute Systemic Toxicity)Non-toxicPassed (Non-toxic)
    Biocompatibility (Material Mediated Pyrogenicity Test)Non-pyrogenicPassed
    Biocompatibility (Subacute/Subchronic Toxicity)No significant toxicityPassed
    Biocompatibility (Implantation)No adverse effectsPassed
    Antimicrobial Preservative Effectiveness (USP<51>)Meet USP 51 and PCPC requirementsPassed (met USP 51 and PCPC requirements)
    Antimicrobial (USP<51> Modified "Time to Kill" Test)99.99% reduction of microorganismsPassed, 99.99% Reduction within 10 minutes of microorganisms including Staphylococcus aureus, Pseudomonas aeruginosa, Escherichia coli, antibiotic resistant strains of MRSA and VRE, as well as fungi such as Candida albicans and Candida auris.
    Endotoxin AnalysisBelow specified limitsPassed, <0.5 EU/mL or <20.0 EU/device
    Nonclinical Wound Healing StudyNo device-related adverse eventsNo device-related adverse events. Results demonstrated the device does not raise different questions of safety and effectiveness compared to standard of care and predicate devices.

    2. Sample Size Used for the Test Set and Data Provenance

    • Clinical Study (Pain Relief): The document states "Subjects were asked to complete an assessment prior to use of the device and within 30 minutes after application of the device." However, the sample size for this clinical study is not explicitly stated.
    • Data Provenance: Not specified, but generally, clinical studies for FDA submissions are prospective. Given the medical device context, it's likely originating from a regulated clinical trial, but country of origin is not mentioned.
    • Other Performance Tests (Biocompatibility, Antimicrobial, Endotoxin): These are laboratory tests typically performed on device samples. The specific number of samples for each test is not provided, but they represent a "test set" of the device material. Data provenance for these lab tests would typically be from a certified testing laboratory.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • For the Clinical Study (Pain Relief): The "ground truth" for pain reduction is based on subjects' self-assessment using a VAS pain score scale. No external experts are mentioned for establishing this ground truth, as it's a self-reported outcome.
    • For other performance tests (e.g., biocompatibility, antimicrobial activity), the "ground truth" is established by the accepted standards and protocols of the respective laboratory tests. The experts involved would be the qualified laboratory personnel conducting these standardized tests. Their specific numbers and qualifications (e.g., toxicologists, microbiologists) are not detailed in this summary.

    4. Adjudication Method for the Test Set

    • For the Clinical Study (Pain Relief): There is no mention of an adjudication process for the VAS pain scores. Scores were directly collected from subjects. Since it's a subjective measure, individual responses constitute the data.
    • For other performance tests: Adjudication is typically not applicable in the same way as expert consensus reviews. The results are determined by objective laboratory measurements against defined standards.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No, an MRMC comparative effectiveness study was not explicitly mentioned or performed for this device. This type of study is more common for diagnostic imaging devices where different readers interpret cases. The Field Shield Wound Dressing is a therapeutic wound dressing, so a different type of clinical evaluation is more appropriate.
    • The clinical study focused on the effectiveness of lidocaine for pain relief, not on reader interpretation.

    6. Standalone Performance (Algorithm Only Without Human-in-the-Loop Performance)

    • This concept is not applicable to the Field Shield Wound Dressing. This is a physical wound dressing and not a software algorithm or AI device. Therefore, there is no "algorithm only" performance to evaluate. The device's performance is intrinsically linked to its physical application and biological interaction with the wound.

    7. Type of Ground Truth Used

    • Clinical Study (Pain Relief): Self-reported patient outcomes (VAS pain scores).
    • Other Performance Tests (Biocompatibility, Antimicrobial, Endotoxin): Established according to recognized scientific and regulatory standards (e.g., ISO, USP, FDA guidance). This includes various in vitro and in vivo laboratory test results.
    • Nonclinical Wound Healing Study: Observation of device-related adverse events and comparison to standard of care in a wound healing model (likely animal model, though not specified).

    8. Sample Size for the Training Set

    • Not Applicable. As a physical medical device, there is no "training set" in the context of machine learning. The device itself is manufactured, and its properties are inherently defined by its composition and manufacturing process, not by a dataset it was trained on.

    9. How the Ground Truth for the Training Set Was Established

    • Not Applicable. Since there is no training set for this device, there is no ground truth to establish for it.
    Ask a Question

    Ask a specific question about this device

    K Number
    K160783

    Validate with FDA (Live)

    Device Name
    Procellera
    Date Cleared
    2016-09-07

    (169 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K062212, K070333, K083103

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For professional use. Procellera® antimicrobial wound dressing is intended for the management of wounds to provide a moist wound environment and is indicated for partial and full-thickness wounds such as pressure ulcers, diabetic ulcers, first and second degree burns, surgical incisions, donor and recipient graft sites, etc.

    For over-the-counter use, Procellera® antimicrobial wound dressing is intended for the management of wounds to provide a moist wound environment and is indicated for superficial wounds such as minor cuts, scrapes, blisters, etc.

    Device Description

    Procellera® is a single layer, broad-spectrum antimicrobial wound dressing: it consists of a polyester substrate containing elemental silver and elemental zinc bound to the surface by a biocompatible binder in a well-characterized dot matrix pattern.

    In the presence of a conductive fluid, such as wound exudate or moisture, a small amount of current is produced at the surface of the device, due to its inherent design. The device is self-contained and has no accessories.

    Procellera® contains Silver and Zinc as preservatives to the dressing, to minimize or prevent the growth of microorganisms within the dressing, not at the wound site, and to help preserve the dressing.

    Procellera® is a primary contact layer dressing and it should be used under a secondary dressing or bandage, which keeps it in place and helps maintain a moist wound environment. Procellera® may be used with other common wound treatment products such as, sutures, staples, liquid skin adhesives, or steri-strips as an adjunct to the local clinical protocols.

    AI/ML Overview

    This document is a 510(k) premarket notification for the Procellera Antimicrobial Wound Dressing, primarily focusing on demonstrating substantial equivalence to predicate devices rather than establishing novel safety and effectiveness through clinical trials with specific acceptance criteria. Therefore, much of the requested information regarding detailed acceptance criteria, specific study designs for performance, number of experts for ground truth, and training set details are not explicitly present in the provided text.

    Based on the information provided, here's an attempt to answer your questions:

    1. A table of acceptance criteria and the reported device performance

    The document does not specify quantitative acceptance criteria in terms of performance metrics (sensitivity, specificity, etc.) typically seen for diagnostic or AI-driven devices. Instead, the "acceptance criteria" are implied by the demonstration of:

    • Substantial Equivalence: The primary objective is to show the device is as safe and effective as legally marketed predicate devices.
    • Biocompatibility: Meeting ISO 10993 standards.
    • Antimicrobial Efficacy (in-vitro within the dressing): Previously cleared for prescription use.
    • Voltage Potential: Generation of sustained, measurable voltage.
    Acceptance Criteria (Implied)Reported Device Performance
    Substantial Equivalence to Predicate DevicesConcluded to be as safe, as effective, and performs as well as the predicate devices (Procellera® K130350, Procellera® K081977, CMBTM Antimicrobial Dressing K060237), which are identical to the current device prior to labeling for OTC use.
    BiocompatibilityTested per ISO 10993 and found to be biocompatible (including cytotoxicity, irritation, sensitization, pyrogenicity, and 28-day subcutaneous implantation).
    Broad-Spectrum in-vitro Antimicrobial EfficacyPreviously submitted to FDA and resulted in clearance for prescription use with an antimicrobial claim. Silver and zinc in the dressing inhibit growth of microorganisms within the dressing. The same data applies to OTC use as products are identical.
    Sustained Voltage Generation (Device Mechanism)Voltage potential testing confirmed that a sustained, measurable voltage is generated on the surface of the device for up to 30 days when immersed in a conductive fluid. (Note: Device use is for up to 7 days, or longer by clinician discretion, and safety beyond 28 days not studied).

    2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)

    The document refers to "in-vitro antimicrobial efficacy testing" and "voltage potential testing." These are laboratory/benchtop tests, not clinical studies involving human patient samples. Therefore, the concept of "sample size for a test set" in the context of human data is not applicable here. The "data provenance" would be laboratory data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g., radiologist with 10 years of experience)

    This information is not applicable. The evaluations are based on laboratory testing (in-vitro efficacy, biocompatibility, voltage potential), not expert interpretation of clinical data where a ground truth would be established by experts.

    4. Adjudication method (e.g., 2+1, 3+1, none) for the test set

    This information is not applicable. Adjudication methods are typically used in clinical studies with expert reviewers, which is not the type of study described here.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    No MRMC study was done, as this device is a wound dressing, not an AI-assisted diagnostic tool or an imaging device that involves human readers.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    This information is not applicable. The device is a wound dressing, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the performance evaluation in this context is based on:

    • Laboratory measurements/standards: For biocompatibility (ISO 10993), in-vitro antimicrobial efficacy (presumably against standard microbial cultures), and electrical properties (voltage measurement).
    • Predicate devices: The "ground truth" for substantial equivalence is the established safety and effectiveness of the existing predicate devices.

    8. The sample size for the training set

    This information is not applicable. There is no mention of a "training set" as this device is not an AI/machine learning model. The studies described are performance tests of the physical device.

    9. How the ground truth for the training set was established

    This information is not applicable, as there is no training set for this type of device submission.