510(k) Data Aggregation

    K Number
    K241802

    Validate with FDA (Live)

    Date Cleared
    2024-11-08

    (140 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K081979, K200064, K192042

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Device 300397 Putty is indicated only for bony voids or gaps that are not intrinsic to the stability of the bony structure. Device 300397 Putty is indicated to be gently packed into bony voids or gaps of the skeletal system (i.e., posterolateral spine, ilium and pelvis). These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. The product provides a bone void filler that resorbs and is replaced with bone during the healing process.

    Device 300397 Putty must be used with blood or autogenous bone marrow aspirate and autograff in posterolateral spine.

    Device Description

    Device 300397 Putty is an osteoconductive, porous, resorbable bone graft substitute which consists of calcium phosphate granules (a-TCP and hydroxyapatite) and Type I and III porcine collagen. The single-patient, single-use product is supplied in three (3) sizes as a sterile, dry block. When mixed with autogenous bone marrow aspirate, blood or sterile non-pyrogenic saline, the product forms a moldable non-setting putty (net volume: 2.5 cc, 5 cc or 10 cc).

    AI/ML Overview

    The provided text is a 510(k) Summary for a medical device (Device 300397 Putty), which is a premarket notification for demonstrating substantial equivalence to a legally marketed predicate device. This type of submission focuses on comparing a new device to an existing one, rather than presenting a detailed clinical study with acceptance criteria, sample sizes, and ground truth establishment in the way typically seen for a novel diagnostic or AI device.

    Therefore, the requested information components related to acceptance criteria, specific study design for proving acceptance criteria for an AI/diagnostic device, sample sizes for test/training sets, expert ground truth establishment, adjudication methods, MRMC studies, and standalone performance metrics are not applicable to this document.

    This document describes a device approval process based on demonstrating substantial equivalence in terms of intended use, technological characteristics, and safety and performance through various tests, primarily non-clinical, not a study designed to meet specific performance metrics against a defined ground truth for a diagnostic outcome.

    However, I can extract information regarding the safety and performance studies that were conducted to support the substantial equivalence claim.

    Here's a summary based on the provided document, addressing the closest relevant points:

    1. Acceptance Criteria and Reported Device Performance:

    The document does not specify quantitative acceptance criteria in the manner of diagnostic performance metrics (e.g., sensitivity, specificity, AUC). Instead, the "acceptance criteria" are implicitly met by successful execution and favorable results of the numerous safety and performance tests to demonstrate substantial equivalence to the predicate device. The "reported device performance" is described qualitatively through these tests.

    CategorySpecific TestDescription of Performance (Implicitly Meets Acceptance)
    Chemical PropertiesAmino Acid Composition, Product Composition, Phase Analysis, FT-IR, SEM, Molecular Weight Distribution, Onset Temperature and Enthalpy of Protein Denaturation, Enzymatic Collagen DegradationThe device components (calcium phosphate granules, porcine collagen) were characterized. The use of a different TCP polymorph compared to the predicate was deemed not to raise different safety/effectiveness concerns due to similar structural composition and chemical stoichiometry. Identified raw material sources for porcine collagen were previously cleared.
    Physical PropertiesPore Size and Pore Size Distribution, Particle Size Distribution, Weight, Dimension, and Density, Determination of Hydrated VolumeGranule size is slightly larger than the predicate but demonstrated through performance testing not to raise new concerns.
    Material HandlingN/A (Studies Conducted)N/A
    SterilizationISO 11137-1:2006, ISO 11137-2:2013, and ISO 11137-3:2017Validation successfully executed.
    PackagingISO 11607-1:2019, ASTM F1980:2007, ASTM F1886/F1886M:2016, ASTM F88:2015, ASTM F1929:2015, and ASTM F2096:2011Validation successfully executed.
    Product StabilityICH Q1A(R2)N/A (Studies Conducted)
    Transport SimulationISTA 3AN/A (Studies Conducted)
    BiocompatibilityISO 10993-1:2018 (comprising Cytotoxicity, Sensitization, Irritation/Intracutaneous Reactivity, Acute Systemic Toxicity, Material Mediated Pyrogenicity, Subacute Systemic Toxicity, Subchronic Systemic Toxicity, Genotoxicity, Implantation (local tissue reaction), Hemocompatibility, Chronic Systemic Toxicity, Elemental Impurities Analysis)Successfully executed. Local tissue reaction was evaluated in accordance with ISO 10993-6:2016.
    In Vivo PerformanceNZ White Rabbit Single Level Spinal Fusion ModelDevice 300397 Putty hydrated with BMA or blood and mixed 1:1 with autograft demonstrated: - Progression in healing vs. time when implanted on decorticated transverse processes in the posterolateral space. - Further healing at host decorticated transverse process interfaces with new bone formation and active osteoblasts. - New bone formation directly on the graft material surfaces. - Confirmed progression and maturation of fusions via histology. - Bone remodeling and new marrow spaces at the decorticated host transverse process interface, with an association with a reduction in local inflammatory cells. Performance evaluated per FDA guidance for calcium salt bone void fillers.

    2. Sample Size and Data Provenance (for test set for AI/diagnostic devices):

    • Not applicable for this 510(k) submission as it's not an AI/diagnostic device.
    • For the in vivo animal study, the model used was the NZ White Rabbit Single Level Spinal Fusion Model. The specific number of animals is not provided in this summary. This is a prospective animal model study.

    3. Number of Experts and Qualifications (for ground truth for AI/diagnostic devices):

    • Not applicable as there is no mention of establishing ground truth by human experts for a diagnostic task.
    • The evaluation of the in vivo study results (e.g., histology interpretation, assessment of bone formation) would typically be performed by veterinary pathologists or experts in orthopedics/bone regeneration, but their specific number and qualifications are not detailed in this summary.

    4. Adjudication Method (for test set for AI/diagnostic devices):

    • Not applicable for this type of device and submission.

    5. MRMC Comparative Effectiveness Study:

    • No, an MRMC comparative effectiveness study for human readers with and without AI assistance was not done, as this is not an AI/diagnostic device.

    6. Standalone Performance Study:

    • No, a standalone algorithm-only performance study was not done, as this is not an AI/diagnostic device.
    • The "standalone" performance for this device is represented by the in vivo animal study where the device's ability to promote bone healing was directly assessed.

    7. Type of Ground Truth Used:

    • For the in vivo animal study, the "ground truth" for assessing bone healing and tissue reaction was based on histology (microscopic examination of tissue samples) and observation of fusion progression in the animal model. This could be considered similar to "pathology" for human studies, reflecting direct biological evidence of effect.

    8. Sample Size for Training Set:

    • Not applicable as this is not an AI/machine learning device that requires a training set.

    9. How Ground Truth for Training Set Was Established:

    • Not applicable as this is not an AI/machine learning device.
    Ask a Question

    Ask a specific question about this device

    K Number
    K181306

    Validate with FDA (Live)

    Device Name
    Actifuse Flow
    Date Cleared
    2018-08-17

    (92 days)

    Product Code
    Regulation Number
    888.3045
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K081979, K130531, K071206, K090850

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Actifuse™ Flow is a bone void filler intended only for orthopedic applications as a filler for gaps and voids that are not intrinsic to the stability of the bony structure. Actifuse™ Flow can be injected into bony voids or gaps of the skeletal system, i.e., extremities, pelvis, and spine, including use in posterolateral spinal fusion procedures with appropriate stabilizing hardware. These defects may be surgically created osseous defects created from traumatic injury to the bone. The product provides a bone void filler that resorbs and is replaced by bone during process.

    Device Description

    Actifuse™ Flow Bone Graft Substitute is a bone void filler intended only for orthopaedic applications as a filler for gaps and voids that are not intrinsic to the stability of the bony structure. Actifuse 11d Flow Bone Graft Substitute can be injected into bony voids or gaps of the skeletal system. i.e., extremities, pelvis, and spine, including use in posterolateral spinal fusion procedures with appropriate stabilizing hardware. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone. The product provides a bone void filler that resorbs and is replaced by bone during the healing process.

    Actifuse™ Flow is phase-pure silicon-substituted calcium phosphate osteoconductive bone void filler, comprising a single-phase calcium phosphate scaffold delivered in a matrix of resorbable polymer. The interconnected and open porous structure inherent of the source material for the mineral phase of Actifuse™ Flow is similar to human cancellous bone.

    AI/ML Overview

    The medical device described in the provided text is Actifuse™ Flow, a resorbable calcium salt bone void filler. The submission is a 510(k) premarket notification for modifications to the product line, specifically applicator syringe design changes.

    Here's an analysis of the acceptance criteria and the study proving the device meets them, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    Parameter / Acceptance CriteriaReported Device Performance and Corresponding Test
    1. Chemical and Structural Integrity of Actifuse™ Flow Acceptance Criteria: The modifications to the applicator syringe should have no impact on the chemistry or structure of the Actifuse™ Flow product, ensuring it remains chemically and structurally identical to the predicate device.Performance Data: The performance of the Actifuse™ Flow device after modifications made to the applicator syringe was assessed by analyzing the Actifuse™ Flow final product for chemical changes relative to the predicate product's specification. Result: "All testing confirmed that the modifications had no impact to the chemistry or structure of the Actifuse™ Flow product."
    2. Biocompatibility Acceptance Criteria: The device, including new materials, must meet biocompatibility standards for a permanent duration, implant device, tissue/bone contact.Performance Data: Biocompatibility assessments were conducted based on ISO-10993-1, "Biological Evaluation of Medical Devices for permanent duration, implant device, tissue/bone contact," and FDA Guidance. Result: "All materials found in these devices that are the subject of this submission have been previously cleared under Baxter's 510(k) premarket notifications K082073 (clearance date September 11, 2008), K130531 (clearance date April 8, 2014) and K071206 (clearance date 31st May, 2007)." This indicates that the materials have already met biocompatibility standards.
    3. Sterility and Package Integrity Acceptance Criteria: The product must be sterile (10^-6 SAL) and remain sterile throughout its shelf life, with package integrity maintained.Performance Data: "The Actifuse™ Flow product line is sterilized with radiation. The minimum sterilizing dose (MSD) required to provide a 10-6 Sterility Assurance Level (SAL) for this (sub) category was established and validated at the manufacturing facility as described in ANSI/AAMI/ISO 11137-2, "Sterilization of health care products- Radiation-Part 2: Establishing the Sterilization Dose."" "Package Verification testing is based on Visual Inspection, Seal Strength, and Bubble Leak testing." Result: "These products are labeled 'Sterile'." The implicit result is that the validation for sterilization and package integrity testing passed, supporting the "Sterile" claim.
    4. Shelf Life Stability Acceptance Criteria: The device must maintain its safety and effectiveness for a defined shelf life.Performance Data: "Baxter has performed aging testing to support a shelf-life claim of two (2) years." Result: The implicit result is that the aging testing successfully demonstrated stability for a two-year shelf life.
    5. Overall Safety and Effectiveness (Substantial Equivalence) Acceptance Criteria: The modified device must be as safe and effective as the predicate device.Performance Data: The entire submission, based on "Discussion of Non-Clinical Data," "Performance Data," "Biocompatibility," "Sterility," and "Shelf Life." Result: "The non-clinical data demonstrate that the subject device is substantially equivalent and performs comparably to the predicate device." "Actifuse™ Flow Bone Graft Substitute is as safe and effective as the predicate Actifuse™ Flow Bone Graft Substitute."

    2. Sample Size Used for the Test Set and Data Provenance

    The provided text does not specify sample sizes for any of the tests. It broadly mentions "All test results meet the acceptance criteria" and "All testing was performed on the configuration of the devices presented in this premarket notification." This suggests that the testing was conducted on a sufficient number of units to support the conclusions, but the exact count is not given.

    The data provenance is pre-market notification testing conducted by Baxter Healthcare Corporation. The location of the testing is not explicitly stated, but Baxter Healthcare Corporation is based in Deerfield, Illinois, USA. The testing appears to be prospective in the sense that it was specifically performed for this 510(k) submission to demonstrate substantial equivalence of the modified device.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Their Qualifications

    There is no mention of experts or the establishment of "ground truth" using human experts for this specific submission. This is a non-clinical submission focused on material and design changes to an existing device, not a clinical study involving diagnosis or interpretation where expert consensus on "ground truth" (e.g., disease presence) would be relevant. The "ground truth" for this submission are the established specifications, chemical properties, and performance characteristics of the predicate device, against which the modified device is compared.

    4. Adjudication Method for the Test Set

    As this is a non-clinical submission, there is no adjudication method described. Adjudication methods (e.g., 2+1, 3+1) are typically used in clinical studies, especially those involving human interpretation of medical images or other subjective data, to resolve discrepancies among readers/experts. These are not applicable to the chemical, physical, and sterility tests described.

    5. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study

    No, a Multi Reader Multi Case (MRMC) comparative effectiveness study was not done. This type of study is relevant for AI or imaging devices where human readers' performance with and without AI assistance is compared. This submission pertains to a physical medical device (bone void filler) with modifications to its applicator syringe, not an AI or imaging diagnostic device.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable. This question typically applies to AI algorithms. The device described is a physical medical product, not an algorithm. The "performance" assessment here relates to chemical, physical, and biological properties of the device itself, not an algorithm's output.

    7. Type of Ground Truth Used

    The "ground truth" used for this submission is based on established specifications, validated test methods, and existing regulatory clearances for the predicate device and the materials used. Specifically:

    • Chemical/Structural Integrity: Ground truth is the defined chemical and structural properties of the predicate Actifuse™ Flow and its components.
    • Biocompatibility: Ground truth is established biocompatibility standards (e.g., ISO-10993-1) and the successful prior clearance of the materials in other Baxter devices.
    • Sterility: Ground truth is a 10^-6 Sterility Assurance Level (SAL) as established by international standards (ANSI/AAMI/ISO 11137-2).
    • Shelf Life: Ground truth is the stability of a product over time, which is confirmed by specific aging tests.

    Essentially, the ground truth is the established and acceptable performance of the predicate device and known standards, against which the modified device is compared.

    8. Sample Size for the Training Set

    There is no mention of a "training set" in this submission. Training sets are relevant for machine learning algorithms. This is a traditional medical device submission based on a direct comparison to a predicate device and engineering/material testing, not machine learning.

    9. How the Ground Truth for the Training Set Was Established

    As there is no training set, this question is not applicable.