510(k) Data Aggregation

    K Number
    K180021

    Validate with FDA (Live)

    Date Cleared
    2018-06-29

    (177 days)

    Product Code
    Regulation Number
    892.5050
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    General Positioning Devices: The device is indicated to aid in supporting and positioning adult and pediatric patients undergoing radiation therapy including electron, photon treatments. The device is also used during image acquisition to support treatment planning. Devices include Couchtops, Cushions, Cushions, and Accessories. The following are other positioning devices:

    Head. Neck. and Shoulders Device is indicated to aid in supporting, positioning, and/or immobilization of adult and pediatric patients undergoing radiation therapy of the head, brain, neck, and spine including radiosurgery and electron, photon, and proton treatments. The device is also used during image acquisition to support treatment planning. Devices include Overlays, Extensions, Thermoplastic Masks, and Cushions.

    Support Garments: The device is indicated to aid in supporting adolescents undergoing radiation therapy including electron, photon treatments. The device is also used during image acquisition to support treatment planning. The device is not intended for use with patients under 12 years of age.

    Breast Positioning Devices: The device is indicated to aid in supporting adult and adolescent patients undergoing radiation therapy of the breast and chest region including electron, photon treatments. The device is also used during image acquisition to support treatment planning. The device is not intended for use with patients under 12 years of age.

    Device Description

    The CIVCO Positioning and Immobilization devices have been used for many years and were previously cleared under other 510(k) is to have these identical Class II products cleared for use in Proton Therapy environment.

    The Head, Neck, and Shoulder Devices are used to treat cancer of the head, neck, brain and spine. Organs that are located in these anatomical regions are applicable.

    The General Positioning Devices are used to treat cancer of the spine, thorax, breast, abdomen, pelvis and prostate. Organs that are located in these anatomical regions are applicable.

    The Support Garments are used to treat cancer of the breast, thorax and abdominal area. Organs that are located in these anatomical regions are applicable.

    The Breast Positioning Devices are used to treat cancer of the breast, thorax and abdominal area. Organs that are located in these anatomical regions are applicable.

    The devices are intended for therapeutic treatment (including proton, photon, and electron beam therapy) and diagnostics (including CT and MR as indicated). The devices will be used in a variety of types of external beam radiation therapy including Intensity Modulated Proton Therapy (IMPT), Intensity Modulated Radiation Therapy (IMRT), Pencil Beam Proton Therapy (PBPT), Image Guided Radiation Therapy (IGRT), Volumetric Modulated Arc Therapy (VMAT), Stereotactic Radiosurgery (SRS), Stereotactic Radiotherapy (SRT), Stereotactic Body Radiation Therapy (SBRT), and Craniospinal Treatment.

    The intended users of the devices are radiation oncology therapists, medical physicists, and oncologists. The provider selects the appropriate equipment based on a patient's individual clinical goals and unique constraints.

    Thermoplastic mask, AccuForm Cushion, and Support Garment devices are single patient use. All devices are non-powered and static.

    The subject devices are reusable or disposable as provided in product labeling, provided non-sterile, and are used in a healthcare facility/hospital. The devices are labeled for MR safety, as applicable.

    AI/ML Overview

    This document is a 510(k) Pre-market Notification for medical devices, specifically Proton Positioning and Immobilization Devices. It is a submission to the FDA to demonstrate substantial equivalence to legally marketed predicate devices, primarily for the modified intended use/indications for use to include proton treatment and pediatric/adolescent use.

    The document does not describe a study involving an algorithm or artificial intelligence (AI) with acceptance criteria in the traditional sense of a computer-aided diagnosis (CAD) or AI-driven diagnostic device. Instead, it describes non-clinical performance testing for physical medical devices. Therefore, many of the requested details about acceptance criteria, ground truth establishment, expert consensus, and multi-reader multi-case (MRMC) studies are not applicable to this type of device submission.

    Here's an interpretation of the relevant information provided, framed as closely as possible to your request for acceptance criteria and study proof for a medical device:

    Device Type: Physical Medical Devices (Positioning and Immobilization for Radiation Therapy)
    Purpose of Submission: To expand the Indications for Use of existing, previously cleared devices to include proton treatment and pediatric/adolescent use.


    1. Table of "Acceptance Criteria" (Performance Goals) and Reported Device Performance

    Given that this is a 510(k) for physical positioning devices, the "acceptance criteria" are not quantitative performance metrics like sensitivity/specificity for an AI algorithm. Instead, they are functional performance goals related to the physical interaction with the proton beam and patient. The "reported device performance" is the confirmation that these functional goals are met.

    Acceptance Criteria (Performance Goal)Reported Device Performance (Conclusion from Testing)
    Primary Goal: Device will not perturb or impact the proton beam in a way that cannot be accounted for in the facility's proton treatment planning process.Devices evaluated, including edge effects, were considered safe and effective for use with proton. The performance tests confirmed that these devices would not perturb or impact the proton beam in a way that cannot be accounted for in the proton treatment planning process. (No recognized threshold for proton attenuation; criteria based on non-perturbation given facility's planning capabilities).
    Maintain safety and effectiveness with expanded use (proton treatment, pediatric/adolescent use).The risk analysis confirmed the safety and effectiveness of similar devices used for pediatrics/adolescents and Proton Therapy, ensuring no new issues are raised. CIVCO devices were found to be safe and effective for use with adults, pediatrics, and/or adolescents in the Proton Therapy environment.
    No additional biocompatibility issues with expanded use.All devices are previously cleared and manufactured with the same or substantially equivalent material that was previously cleared, thus no additional biocompatibility testing is required.
    Devices used in MRI environment maintain their MR safety.Devices labeled for use in an MRI environment were previously cleared by predicate 510(k)s included in this submission. Therefore, no additional MR testing is required.
    Mechanical function without software/electronics.Confirmed: The devices are mechanical without the use of software or electronics.
    Limited contact duration (<24 hours) for surface devices (skin).Confirmed: The devices are intended for limited contact duration (<24 hours) for surface devices (skin).
    Devices are non-sterile.Confirmed: Devices are non-sterile.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: The document does not specify a quantitative "sample size" in terms of number of devices tested or number of patient images/cases. The testing appears to be conducted on representative devices from the product families concerned. It mentions "devices were selected for performance testing" and "devices were evaluated." For physical devices like these, performance testing often involves a small number of physical units to verify properties.
    • Data Provenance: Not applicable in the sense of patient data. The "study" is a non-clinical, in-house performance evaluation and literature review. This is not retrospective or prospective patient data, but rather engineering-level testing of the device's interaction with a proton beam.
      • Country of Origin: The non-clinical testing was performed by CIVCO (MEDTEC, Inc.), which is located in the USA (Orange City, Iowa).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    This question is not directly applicable. The "ground truth" for these physical devices is established by physical measurements and engineering principles related to proton beam physics and material interactions, rather than expert interpretation of medical images.

    The document states: "Because there is no recognized threshold for Proton attenuation, the criteria used for determining acceptable performance was to verify the part will not perturb or impact the proton beam in a way that cannot be accounted for in the facility's proton treatment planning process." This implies reliance on established physics and a facility's ability to plan around the device, rather than a clinical "truth" adjudicated by experts.

    The intended users of the devices are mentioned as "radiation oncology therapists, medical physicists, and oncologists," implying their expertise is relevant for the clinical application but not for establishing the fundamental physical properties of the device materials.


    4. Adjudication Method for the Test Set

    Not applicable. This is not a study requiring adjudication of expert disagreement or clinical findings. Performance is assessed against physical properties and effects on proton beams.


    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study was done

    No, an MRMC comparative effectiveness study was not done. This type of study is relevant for diagnostic imaging devices where human readers interpret medical images with and without AI assistance. The devices in this submission are physical positioning and immobilization tools, not diagnostic AI software.


    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Yes, in a conceptual sense, the "standalone" performance of the physical devices was assessed. The non-clinical testing evaluated the physical interaction of the devices with the proton beam independent of a "human-in-the-loop" clinical application, to ensure they meet the criteria of "not perturbing or impacting the proton beam in a way that cannot be accounted for in the facility's proton treatment planning process."


    7. The Type of Ground Truth Used

    The ground truth used is primarily physics-based experimental data related to proton beam attenuation and material properties, and engineering validation that the devices maintain their mechanical function and safety characteristics when exposed to a proton environment or used by various patient populations (pediatric/adolescent). The lack of a "recognized threshold for Proton attenuation" indicates that the "ground truth" for acceptable performance is framed by a facility's ability to integrate the device's known characteristics into their treatment planning.


    8. The Sample Size for the Training Set

    Not applicable. These are physical medical devices, not an AI algorithm, so there is no concept of a "training set" for model development.


    9. How the Ground Truth for the Training Set was Established

    Not applicable, as there is no training set for an AI algorithm.

    Ask a Question

    Ask a specific question about this device

    K Number
    K081916

    Validate with FDA (Live)

    Date Cleared
    2008-07-22

    (15 days)

    Product Code
    Regulation Number
    892.1000
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K080072

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GE Signa® MR Oncology Package is a patient positioning package intended for use with GE Signa® MR Systems.

    The Signa® MR Oncology Package when used with a Signa® MR system is a whole body magnetic resonance scanner designed to support high resolution, high signal-to-noise ratio and short scan times. The Signa® MR system with Signa® MR Oncology Package is indicated for use as a diagnostic imaging device to produce axial, sagittal, coronal and oblique images, spectroscopic images, and/or spectra, dynamic images of the internal structures and organs of the entire body, including, but not limited to, head, neck, TMJ, spine, breast, heart, abdomen, pelvis, joints, prostate, blood vessels, and musculoskeletal regions of the body. The images produced by the Signa® MR system with Signa® MR Oncology Package reflect the spatial distribution of protons (hydrogen nuclei) exhibiting magnetic resonance. These images and/or spectra when interpreted by a trained physician yield information that may assist in diagnosis.

    The Signa® MR Oncology Package provides an additional patient table for Signa® MR systems that allows patients to be imaged on a flat surface. The flat patient surface enables Signa® MR systems to acquire images in patient positions similar to other modalities that also utilize a flat patient surface such as X-Ray, CT, PET, and radiation therapy. The Signa® MR system with Signa® MR Oncology Package may also be used with MR-compatible patient positioning and immobilization accessories to assist in obtaining consistent patient positions throughout multiple imaging sessions.

    Device Description

    The GE Signa® MR Oncology Package includes a patient table that can be used with a GE Signa® MRcompatible patient positioning and immobilization devices. The Signa® Oncology Table is similar to the existing detachable patient table offered with Signa® MR Systems. It utilizes the detachable table system to offer a flat patient surface. The flat surface enables patients to be positioned similar to other diagnostic and therapeutic devices that also utilize flat patient surfaces. Also, the Signa® MR Oncology Package may be used with MR-compatible patient immobilization accessories to assist in consistent positions throughout multiple imaging sessions.

    AI/ML Overview

    The GE Signa® MR Oncology Package is an accessory for existing GE Signa® MR Systems, primarily involving a modified patient table for oncology imaging. The provided 510(k) summary focuses on demonstrating substantial equivalence to its predicate device rather than presenting a detailed study with specific acceptance criteria related to diagnostic performance metrics like sensitivity or specificity for a standalone AI algorithm. It's a hardware modification intended to enhance positioning and imaging consistency.

    Here's an analysis of the provided information:

    1. Acceptance Criteria and Reported Device Performance

    The document describes the device as an accessory and focuses on demonstrating that the modified table maintains the same imaging performance as the existing patient table with Signa® HDx MR System.

    Acceptance Criteria CategorySpecific Acceptance CriteriaReported Device Performance
    SafetyCompliance with IEC 60601-1 (Medical Electrical Equipment - Part 1: General Requirements for Safety standard)Evaluated and found compliant.
    BiocompatibilityCompliance with ISO 10993-1 (Biological Evaluation of Medical Devices - Part 1: Evaluation and Testing) and related parts 10993-5 and 10993-10 for biocompatibility of patient contacting surface.Patient contacting surface evaluated and found compliant.
    Functional EquivalenceModified table functions with the Signa® HDx MR System.Verified to function.
    Imaging Performance EquivalenceClinical image comparisons demonstrate that the Signa® MR Oncology Package maintains the same imaging performance as the Signa® HDx MR System with existing patient table.Clinical image comparisons demonstrate maintained imaging performance.

    2. Sample Size for Test Set and Data Provenance

    The document states "clinical image comparisons" were performed but does not specify the sample size (number of patients or images) used for these comparisons.
    Data Provenance: The document does not explicitly state the country of origin or whether the data was retrospective or prospective. Given that it's a comparison study for a hardware modification, it's likely institutional data.

    3. Number of Experts and Qualifications for Ground Truth

    The document mentions "clinical image comparisons" and that images, when interpreted by a "trained physician," yield information that may assist in diagnosis. However, it does not specify the number of experts used to establish ground truth for the test set or their specific qualifications (e.g., "radiologist with 10 years of experience").

    4. Adjudication Method for the Test Set

    The document does not specify any adjudication method (e.g., 2+1, 3+1, none) used for the clinical image comparisons.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No MRMC comparative effectiveness study was mentioned in the provided text. The device is a patient positioning accessory, and the study focuses on its safety and equivalence in imaging performance, not on demonstrating an improvement in human reader performance with or without an AI assist.

    6. Standalone (Algorithm Only) Performance

    No standalone algorithm performance study was conducted or is applicable here. The device is a physical accessory (patient table) for an MR system, not an AI software algorithm.

    7. Type of Ground Truth Used

    The type of ground truth used for the clinical image comparisons is not explicitly stated beyond "images... when interpreted by a trained physician yield information that may assist in diagnosis." This implies a clinical diagnosis by a physician, but details like "expert consensus, pathology, or outcomes data" are not provided.

    8. Sample Size for the Training Set

    This information is not applicable. The device is a hardware accessory, not a machine learning model, so there is no "training set."

    9. How Ground Truth for the Training Set Was Established

    This information is not applicable. As mentioned above, there is no training set for this hardware device.

    Ask a Question