Search Filters

Search Results

Found 2 results

510(k) Data Aggregation

    K Number
    K072729

    Validate with FDA (Live)

    Device Name
    SIERRA
    Manufacturer
    Date Cleared
    2008-04-17

    (204 days)

    Product Code
    Regulation Number
    888.3050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K062934, K022048, K033961, K043229

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the Sierra spinal system is to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput-T3). The indications for use are as follows:

    • degenerative disc disease (DDD) as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies,
    • spondylolisthesis. .
    • trauma (i.e., fracture or dislocation), .
    • . spinal stenosis.
    • atlantoaxial fracture with instability, .
    • occipitocervical dislocation, .
    • revision of previous cervical spine surgery, and/or
    • . spinal tumor.

    The occipital bone screws are limited to occipital fixation only.

    The use of the polyaxial screws is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine.

    Device Description

    Rod connectors, crossbars and set screws are being added to the Sierra spinal system. All products are fabricated from titanium alloy. All products are supplied "NON-STERILE" and must be sterilized prior to use.

    AI/ML Overview

    This document describes a 510(k) premarket notification for the Sierra™ spinal system, specifically referring to the addition of rod connectors, crossbars, and set screws. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than conducting a full clinical study to prove novel efficacy or safety. Therefore, the provided information does not include details on acceptance criteria, a study proving performance against those criteria, or specific metrics like sensitivity, specificity, or reader improvement with AI.

    Here's an analysis based on the provided text, highlighting the absence of the requested information due to the nature of a 510(k) submission:

    1. A table of acceptance criteria and the reported device performance

    • Acceptance Criteria: Not explicitly stated as performance metrics in the provided document. For 510(k) submissions, the “acceptance criteria” typically revolve around demonstrating substantial equivalence in terms of functionality, technological characteristics, and safety to a predicate device. This is often achieved through comparative testing (e.g., mechanical, material) and analysis rather than clinical performance metrics.
    • Reported Device Performance: Not reported in terms of clinical outcomes or specific performance metrics (e.g., sensitivity, specificity, accuracy). The submission asserts that the new components have "substantially equivalent technological characteristics to the predicate devices."

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Sample Size for Test Set: Not applicable/not provided. This document does not describe a clinical study in the traditional sense involving a "test set" of patients or data for performance evaluation. The "testing" likely involved mechanical and material characterization of the new components against established standards or predicate device specifications.
    • Data Provenance: Not applicable/not provided.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not applicable/not provided. Ground truth establishment by medical experts is typically part of clinical performance studies, which are not detailed in this 510(k) submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not applicable/not provided. Adjudication methods are relevant for clinical studies that involve expert review of cases, which is not the focus of this document.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: No. This document concerns a conventional medical device (spinal fixation system components), not an AI-powered diagnostic or assistive tool.
    • Effect size of human reader improvement with AI: Not applicable, as no AI component is described.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not applicable, as no algorithm or AI component is described.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not applicable. The "ground truth" for a 510(k) submission like this would involve demonstrating that the new components meet established engineering and material standards, and perform comparably to predicate devices in mechanical and functional tests. It is not about clinical ground truth derived from patient data.

    8. The sample size for the training set

    • Not applicable. There is no mention of an algorithm or AI requiring a training set.

    9. How the ground truth for the training set was established

    • Not applicable. There is no mention of an algorithm or AI requiring a training set or ground truth establishment in this context.

    Summary of what the document does provide:

    • Predicate Devices: SeaSpine, Inc.'s Sierra Spinal System (K062934) and Interpore Cross International's Altius OCT System (K022048, K033961 and K043229).
    • Basis for Equivalence: "The overall designs of the rod connectors, crossbars and set screws in this submission are substantially equivalent to the predicate devices." and "The devices in this submission have substantially equivalent technological characteristics to the predicate devices."
    • Materials: All products are fabricated from titanium alloy.
    • Intended Use: Promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput-T3) for various conditions (degenerative disc disease, spondylolisthesis, trauma, spinal stenosis, atlantoaxial fracture with instability, occipitocervical dislocation, revision of previous cervical spine surgery, and spinal tumor).
    • Limitations: Occipital bone screws limited to occipital fixation; polyaxial screws limited to T1-T3 for thoracic conditions only, not for cervical spine.

    In conclusion, this document is a 510(k) summary for a conventional medical device modification, which focuses on demonstrating substantial equivalence to existing devices based on technological characteristics and intended use, rather than presenting clinical study results with performance metrics or AI algorithm validation.

    Ask a Question

    Ask a specific question about this device

    K Number
    K080526

    Validate with FDA (Live)

    Device Name
    SIERRA SYSTEM
    Manufacturer
    Date Cleared
    2008-04-16

    (50 days)

    Product Code
    Regulation Number
    888.3050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K062934, K022048, K033961, K043229

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The intended use of the Sierra spinal system is to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput-T3). The indications for use are as follows:

    • degenerative disc disease (DDD) as defined by neck pain of discogenic origin with . degeneration of the disc confirmed by patient history and radiographic studies,
    • spondylolisthesis. .
    • trauma (i.e., fracture or dislocation), .
    • spinal stenosis, .
    • atlantoaxial fracture with instability, .
    • occipitocervical dislocation, .
    • revision of previous cervical spine surgery, and/or .
    • . spinal tumor.
      The occipital bone screws are limited to occipital fixation only.
      The use of the polyaxial screws is limited to placement in the upper thoracic spine (T1-T3) in treating thoracic conditions only. They are not intended to be placed in the cervical spine.
    Device Description

    A new occipital plate design is being added to the Sierra spinal system. All products are fabricated from titanium alloy and cobalt alloy. All products are supplied "NON-STERILE" and must be sterilized prior to use.

    AI/ML Overview

    This document is a 510(k) premarket notification for the Sierra™ OCT Spinal System, specifically for the addition of a new occipital plate design. It is a submission to the FDA (Food and Drug Administration) for regulatory clearance. Since this is a submission for a Special 510(k) and the information provided points to substantial equivalence with existing predicate devices, the focus is on design and material equivalency, rather than clinical performance studies involving a test set, ground truth, or human-in-the-loop assessments as would be done for AI/ML-driven devices.

    Therefore, many of the requested categories for acceptance criteria and study details are not applicable to this type of submission. The "acceptance criteria" here refer to satisfying FDA's requirements for substantial equivalence based on design, materials, and intended use.

    Here's the breakdown of the information based on the provided document:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria (for Substantial Equivalence)Reported Device Performance/Characteristics
    Overall Design Equivalence to Predicate Devices (Sierra Spinal System K062934 and Interpore Cross International's Altius OCT System K022048, K033961, K043229)"The overall design of the occipital plates in this submission is substantially equivalent to the predicate devices."
    Materials Equivalence"All products are fabricated from titanium alloy and cobalt alloy." (Implied to be equivalent to predicate device materials, as no material change is highlighted as a differentiator)
    Intended Use Equivalence"The statements of intended use are identical." The intended use is to promote fusion of the cervical spine and occipito-cervico-thoracic junction (occiput-T3) for various conditions (DDD, spondylolisthesis, trauma, spinal stenosis, atlantoaxial fracture with instability, occipitocervical dislocation, revision, spinal tumor). Specific limitations for occipital bone screws (occipital fixation only) and polyaxial screws (T1-T3 only, not cervical spine) are also identical.
    Technological Characteristics Equivalence"The addition of the new devices has not altered the fundamental scientific technology of the previously cleared system. The devices in this submission have substantially equivalent technological characteristics to the predicate devices."
    Sterilization Status Equivalence"All products are supplied "NON-STERILE" and must be sterilized prior to use." (Implied to be equivalent to predicate devices, as this is a common practice for such implants.)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not applicable (N/A). This submission is for a medical device (occipital plate) and relies on substantial equivalence to predicate devices, not clinical performance data from a test set of patients in the way an AI/ML device would. No patient data or test set in the traditional sense was used.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • N/A. Ground truth establishment is not relevant for this type of submission, which focuses on engineering and design equivalency.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • N/A. No test set or human adjudication process as described is relevant.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • N/A. This is not an AI/ML device, so no MRMC study or AI assistance evaluation was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • N/A. This is not an algorithm or AI system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • N/A. The "ground truth" equivalent in this context is the regulatory acceptance of the predicate devices based on their established safety and effectiveness. The new device is deemed safe and effective because its characteristics are substantially equivalent to those already cleared devices.

    8. The sample size for the training set

    • N/A. No training set is relevant for this device.

    9. How the ground truth for the training set was established

    • N/A. No ground truth for a training set was established.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1