510(k) Data Aggregation

    K Number
    K151619

    Validate with FDA (Live)

    Date Cleared
    2015-10-30

    (136 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K051463

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    1. Prime&Bond Elect® Universal Dental Adhesive (visible light cured):
      • 1.1 Direct, light cured composite and compomer restorations
      • 1.2 Indirect restorations; light cured, resin cemented veneers
      • 1.3 Indirect restorations; acid-tolerant resin cement (dual cure or self-cure) cemented inlays, onlays, crown and bridge retainers
      • 1.4 Composite, ceramic and amalgam repairs
      • 1.5 Cavity varnish for use with fresh amalgam
      1. Prime&Bond Elect® Universal Dental Adhesive mixed with Self-Cure Activator (dual cure or self-cure):
      • 2.1 Direct, dual cure or self-cure composite restorations and core build-ups
      • 2.2 Indirect restorations; dual cured and self-cured resin cemented inlays, onlays, crown and bridge retainers
      • 2.3 Dual cured and self-cured resin cemented endodontic post cementation
      1. Prime&Bond Elect® Universal Dental Adhesive mixed with Self-Cure Activator and Amalgam Bonding Base & Catalyst:
      • 3.1 Adhesive bonding of direct amalgam restoration
      1. Prime&Bond Elect® Universal Dental Adhesive (without Self-Cure Activator or adhesive curing):
      • 4.1 Indirect restorations: acid-tolerant resin cement light-cured cementation; light transmissible inlays, onlays, crown and bridge retainers with light curing of cement
      • 4.2 Indirect restorations; acid-tolerant resin cement dual cure or self-cure cementation; limited light/light opaque inlays, onlays, crown and bridge retainers and endodontic posts with total etch technique
    Device Description

    Prime&Bond Elect® Universal Dental Adhesive is a universal self-priming dental adhesive system designed to bond resin based materials to enamel and dentin as well as to metals and ceramic. Prime&Bond Elect® Universal Dental Adhesive combines etchant, primer and adhesive in a one-bottle material. This robust formulation allows the operator to utilize selective phosphoric acid etching of enamel, phosphoric acid etching of both enamel and dentin, or no phosphoric acid etching prior to application, ensuring high bond strength and protection against microleakage.

    When mixed with Self-Cure Activator, Prime&Bond Elect® Universal Dental Adhesive is designed to be used with DENTSPLY manufactured dual cure/self-cure resin cements* to bond all indirect restorations and DENTSPLY manufactured dual cured composite restoratives. When used with the Amalgam Bonding Accessory Kit, available separately, Prime&Bond Elect® Universal Dental Adhesive also adhesively bonds fresh amalgam to enamel and dentin.

    *Note: Acid-tolerant resin cements may be used following application of Prime&Bond Elect® adhesive without the use of Self-Cure Activator, additionally allowing operator's choice of pre-cementation adhesive curing options (see complete Directions for Use).

    AI/ML Overview

    The provided text includes information about the DENTSPLY International Inc. device, Prime&Bond Elect® Universal Dental Adhesive. However, it does not describe specific acceptance criteria in the form of numerical thresholds for device performance, nor does it detail a standalone study proving the device meets acceptance criteria.

    Instead, the document states that the proposed device (Prime&Bond Elect® Universal Dental Adhesive) has an identical design and formulation to a predicate device (XENO® Adhesive with Activator, K051463), meaning the biocompatibility and performance data of the predicate device support the proposed device. A table of "Physical Properties Tested" is provided, and for each property, the result is simply "Meets specification," without providing the actual specifications or measured values.

    Therefore, many of the requested items (sample size, data provenance, number of experts, adjudication method, MRMC study details, ground truth type and establishment for training, and specific acceptance criteria with numerical performance) cannot be extracted from this document, as a typical clinical study with such details was not conducted or reported for this 510(k) submission.

    Here's a summary of the available information based on your request:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria (Implied)Reported Device Performance
    Film Thickness specificationMeets specification
    Dentin Shear Bond Strength, Indirect specificationMeets specification
    Enamel Shear Bond Strength, Indirect specificationMeets specification
    Dentin Shear Bond Strength, Direct specificationMeets specification
    Enamel Shear Bond Strength, Direct specificationMeets specification
    Composite Bond Strength, Indirect specificationMeets specification
    Base Metal Shear Bond Strength, Indirect specificationMeets specification
    Noble Metal Shear Bond Strength, Indirect specificationMeets specification
    Zirconia Ceramics Bond Strength, Indirect specificationMeets specification
    Glass Ceramic Shear Bond Strength, Indirect specificationMeets specification
    Shelf Life specification2 Years

    Note: The document states "all of the test results have met the specifications" but does not provide the specific numerical specifications or the measured results.

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
    Not provided in this document. The document relies on the predicate device's data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
    Not applicable. No multi-reader, ground truth establishment study is described. The performance claim is based on equivalence to a predicate device and physical property testing.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
    Not applicable.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
    No, a MRMC comparative effectiveness study was not done. The device is a dental adhesive, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
    Physical property testing was done for the standalone device. The results are summarized generically as "Meets specification" without providing numerical values or sample sizes. The biocompatibility and primary performance claims are based on the predicate device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)
    For the physical properties listed, the "ground truth" would be established by standardized material testing procedures and their associated specifications. No details on these specific standards or how the specifications were derived are provided in this document. For the overall performance, the "ground truth" is the performance of the legally marketed predicate device (K051463), whose data was used as a basis for substantial equivalence.

    8. The sample size for the training set
    Not applicable. There's no machine learning algorithm described.

    9. How the ground truth for the training set was established
    Not applicable.

    Ask a Question

    Ask a specific question about this device

    K Number
    K082753

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-11-24

    (66 days)

    Product Code
    Regulation Number
    872.3200
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    M0176, K051463

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    • Futurabond M/Futurabond M Single Dose is suited as adhesive for direct restoration with light-curing filling materials in all cavity classes.
    • Futurabond M/Futurabond M Single Dose is also suited for cavity sealing as a pretreatment for indirect restorations
    • Futurabond M/Futurabond M Single Dose is also suited for the treatment of exposed root surfaces
    • Futurabond M/Futurabond M Single Dose can be used for core build-ups using light-cured or dual-cured filling materials.
    Device Description

    Futurabond M/Futurabond M Single Dose is a single-component, light-curing, self-etch-bond reinforced with nano-particles to build a durable bond between tooth substance and light-curing filling materials without marginal leakage.

    Futurabond M/Futurabond M Single Dose displays the same adhesive properties of totaletch preparations without separate etching of the tooth substance.

    Futurabond M/Futurabond M Single Dose tolerates residual moisture.

    Futurabond M/Futurabond M Single Dose is an all-purpose adhesive for use with all lightcuring composites, compomers and Ormocer®s.

    Futurabond M/Futurabond M Single Dose is offered in 5 ml plastic bottles (Futurabond M) and in 0.06 ml Single Dose blisters (Futurabond M Single Dose).

    AI/ML Overview

    This document is a 510(k) summary for the dental adhesive device, "Futurabond M/Futurabond M Single Dose". It does not describe an AI or machine learning device, nor does it provide a study that proves the device meets acceptance criteria in the format requested. Instead, it details the device's characteristics, intended use, and argues for substantial equivalence to predicate devices based on identical composition and performance characteristics.

    Therefore, most of the requested information regarding acceptance criteria, study details, sample sizes, expert involvement, and ground truth establishment is not present in this document as it pertains to a different type of device and regulatory submission.

    However, I can extract the following relevant information:

    1. Acceptance Criteria and Reported Device Performance (Implied):

    The document implies that the "acceptance criteria" revolve around demonstrating that Futurabond M/Futurabond M Single Dose has "the same adhesive properties" and is "identical in composition and performance characteristics" to the legally marketed predicate devices. This is not a quantitative acceptance criterion with specific thresholds as would be expected for an AI device.

    Acceptance Criteria (Implied)Reported Device Performance (Implied)
    Same adhesive properties as predicate devices."Futurabond M/Futurabond M Single Dose displays the same adhesive properties of total-etch preparations without separate etching of the tooth substance."
    Identical in composition to predicate devices."All of the components of Futurabond M/Futurabond M Single Dose are found in the legally marketed devices K042913 (Clearfil S$^3$Bond), M0176 (Clearfil S$^3$Bond Single Dose) and K051463 (Xeno Adhesive with Activator)."
    Identical in performance characteristics to predicate devices."Futurabond M and Futurabond M Single Dose are identical in composition and performance characteristics."

    2. Sample size used for the test set and the data provenance: Not applicable. This document does not describe a clinical study with a test set of data. The claims are based on material composition and established performance of predicate devices.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. No ground truth establishment by experts for a test set is described.

    4. Adjudication method for the test set: Not applicable. No adjudication method for a test set is described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is not an AI/ML device.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable. This is not an AI/ML device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable in the context of an AI/ML device. The "ground truth" for this submission is implicitly the established safety and effectiveness of the identified predicate devices, based on their prior regulatory clearance and market history.

    8. The sample size for the training set: Not applicable. This is not an AI/ML device.

    9. How the ground truth for the training set was established: Not applicable. This is not an AI/ML device.