    K Number
    K180348

    Validate with FDA (Live)

    Date Cleared
    2018-07-17

    (159 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K121425, K143050, K050681, K124027

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Field Orthopaedics Micro Screw System consists of the following kits with the following indications:

    The FO Micro Screw Kit is intended for fixation of fractures, osteotomies, and arthrodeses of small bones in the foot, hand, and forearm.

    The FO Pin and Wire Kit is intended for fixation of bone fractures or as guidance at insertion of implants into the skeletal system.

    Device Description

    The Field Orthopaedics Micro Screw System is an extremity trauma system consisting of the FO Micro Screw Kit and the FO Pin and K-Wire Kit.

    The FO Micro Screw Kit includes 1.5 mm and 2.0 mm diameter cannulated compression screws with lengths ranging from 6 mm to 16 mm increments and 0.6 mm single trocar K-wires of length 70 mm. Accompanying the screws is a specifically designed instrument kit, tailored to the insertion of the 1.5 and 2.0 FO Micro Screw.

    The FO Pin and K-Wire Kit includes 0.6, 0.8, 1.0 and 1.2 mm double trocar K-wires of length options 70 mm and 150 mm; and 1.6 and 2.0 mm double trocar Pins of length 150 mm. Accompanying the FO Pins and K-Wires are appropriately sized guide sleeves to aid insertion.

    Materials: All Field Orthopaedics Micro Screws are made from Titanium Alloy (ASTM F136).

    All Field Orthopaedics Pins and K-Wires are made from Stainless Steel Alloy (ASTM F138).

    The instrumentation is made from medical grades stainless steel, anodized aluminium, and marked with epoxy resin.

    AI/ML Overview

    The provided text describes the 510(k) summary for the Field Orthopaedics Micro Screw System and does not contain information about the acceptance criteria or a study proving the device meets specific performance metrics in the context of an AI/ML device.

    The document discusses the mechanical performance of a physical medical device (screws, pins, and K-wires for bone fixation) and compares it to predicate devices based on:

    • Mechanical testing: Torsional strength, maximum torque to drive-in and remove screws, and pull-out force, as per ASTM F543.
    • Theoretical engineering analyses.
    • Simulated surgeon-user testing.

    It concludes that the device possesses greater strength than predicate devices and meets the strength requirements for solid screws (ASTM F543).

    Therefore, I cannot extract the requested information (such as acceptance criteria table with reported device performance, sample sizes for test/training sets, data provenance, number of experts for ground truth, adjudication methods, MRMC studies, standalone algorithm performance, or ground truth types for AI/ML models) because this document is about the regulatory submission for a physical orthopedic implant system, not a software/AI/ML medical device.

    Ask a Question

    Ask a specific question about this device

    K Number
    K111266

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-10-06

    (155 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K050681

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EasyLock XXS Plates are indicated for fixation of fractures in phalangeal and metacarpal bones.

    Device Description

    The XXS Plates utilize the same integrated locking system for screws as the Xtremities Plates cleared in K050681. The titanium plates have PEEK-Optima® inserts which enables the screws to be locked at the desired angle by means of a "self-tapping" effect. The XXS Plats are thinner and smaller diameter screws (1.7mm) have been designed for use in small bones including the metacarpals and phalanges.

    AI/ML Overview

    The provided text is a 510(k) summary for the TRIMED EASYLOCK OSTEOSYSTEM XXS PLATES. It details the device description, indications for use, and a comparison to predicate devices to establish substantial equivalence. However, this document does not contain information about acceptance criteria, a specific study proving the device meets acceptance criteria, sample sizes, expert qualifications, or ground truth establishment.

    The document is a premarket notification for a medical device (bone fixation plates and screws). For this type of device, substantial equivalence is typically established by demonstrating that the new device has the same intended use, technological characteristics, and performs as safely and effectively as a legally marketed predicate device. This often involves comparing design features, dimensions, material composition, and sometimes mechanical testing data. However, detailed study results with acceptance criteria, sample sizes, and ground truth information as requested for AI/software device evaluation are not typically part of a 510(k) for a physical orthopedic implant.

    Therefore, for the questions asked, the answer is that the information is not present in the provided document. Devices like the TRIMED EASYLOCK OSTEOSYSTEM XXS PLATES typically rely on mechanical testing (e.g., fatigue, static strength) and biocompatibility testing for safety and effectiveness, rather than clinical studies with human readers or AI algorithms described in the prompt's questions.

    Here's a breakdown of why each point cannot be answered from the provided text:

    1. A table of acceptance criteria and the reported device performance: Not present. The submission focuses on substantial equivalence to predicate devices, not specific performance metrics against pre-defined acceptance criteria for a new study.
    2. Sample size used for the test set and the data provenance: Not present. No specific test set or study data is described.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not present. This type of information is relevant for studies involving human interpretation (e.g., imaging devices) rather than a physical implant.
    4. Adjudication method for the test set: Not present.
    5. If a multi-reader multicase (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not relevant and not present. This is a physical implant, not an AI-powered diagnostic tool.
    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not relevant and not present.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not present.
    8. The sample size for the training set: Not present. No training set is mentioned as this is not an AI/machine learning device.
    9. How the ground truth for the training set was established: Not present.