Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K073115

    Validate with FDA (Live)

    Device Name
    ORTHOMESH
    Manufacturer
    Date Cleared
    2008-07-15

    (253 days)

    Product Code
    Regulation Number
    888.3030
    Age Range
    All
    Predicate For
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Synthes OrthoMesh Resorbable Graft Containment system is indicated for use in maintaining the relative position of weak bony tissue such as bone grafts, bone graft substitutes or bone fragments from comminuted fractures.

    OrthoMesh implants may be used alone (without traditional rigid fixation) to maintain the relative position of bone grafts, bone graft substitutes or bone fragments in non-load-bearing reconstructive procedures involving areas where bone stability has not been compromised, such as tumor resections and iliac crest graft harvest sites.

    OrthoMesh implants must be used in conjunction with traditional rigid fixation in load bearing applications to maintain the relative position of bone grafts, bone graft substitutes or bone fragments in reconstructive procedures involving long bones, flat bones, short bones, irregular bones, appendicular skeleton and thorax. These devices are not intended for use in the spine. The devices are not intended for load bearing indications unless used in conjunction with traditional rigid fixation

    Device Description

    The Synthes OrthoMesh Resorbable Graft Containment System is comprised of meshes of 0.5mm, 0.8mm and 1.2mm thickness, and lengths and widths ranging from 48mm to 125mm. The Synthes OrthoMesh Resorbable Graft Containment System is also comprised of screws with a diameter ranging from 1.5mm to 2.5mm, and a length ranging from 4mm to 8mm. These implants are made from the resorbable copolymer poly (L-lactide-co-glycolide) that resorbs in vivo by hydrolysis into lactic and glycolic acids, and that are then metabolized by the body. Synthes OrthoMesh implants are resorbed completely within approximately 12 months. The implants are provided sterile and are intended for single patient use. OrthoMesh may be held in place with screws.

    AI/ML Overview

    The provided text does not contain information about acceptance criteria or a study that proves a device meets those criteria.

    The document is a 510(k) summary and an FDA clearance letter for the Synthes OrthoMesh Resorbable Graft Containment System. It describes the device, its intended use, contraindications, and declares its substantial equivalence to predicate devices. However, it does not include performance data, clinical study results, or specific acceptance criteria for device performance.

    Therefore, I cannot provide the requested information in the table or answer the specific questions about sample size, data provenance, ground truth establishment, or multi-reader multi-case studies because this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1