    K050943

    Validate with FDA (Live)

    Device Name
    GE VIEWPOINT
    Date Cleared
    2005-05-23

    (39 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K041029

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The GE ViewPoint is intended to accept, transfer, display, store and process medical images and data, including the ability to measure, calculate, annotate and prepare and print patient examination reports primarily for diagnostic ultrasound.

    Device Description

    GE ViewPoint is a software based medical image management system providing the ability to review exam images and data, prepare and printing reports and communicate with ultrasound scanners and other PACS devices via DICOM or other network protocol. It is sold with or without the designated computer hardware.

    AI/ML Overview

    This document is a 510(k) premarket notification for the GE ViewPoint Image Management and Reporting System, submitted on April 12, 2005. It provides general information about the device and asserts its substantial equivalence to a predicate device. However, it does not contain any specific acceptance criteria or details of a study demonstrating the device meets such criteria in terms of performance metrics.

    The document explicitly states:

    • "Clinical Tests: None required to confirm safety and effectiveness. However, evaluation in a clinical setting is performed to help assure reliability and compatibility within the intended network environment."

    Therefore, based solely on the provided text, the following information cannot be extracted:

    1. A table of acceptance criteria and the reported device performance: Not provided. The submission focuses on substantial equivalence based on intended use and technological characteristics to a predicate device, not on specific performance metrics against defined acceptance criteria.
    2. Sample sizes used for the test set and data provenance: Not applicable as no performance testing study against acceptance criteria is described.
    3. Number of experts used to establish the ground truth for the test set and their qualifications: Not applicable.
    4. Adjudication method for the test set: Not applicable.
    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, and its effect size: Not applicable.
    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable.
    7. The type of ground truth used: Not applicable.
    8. The sample size for the training set: Not applicable.
    9. How the ground truth for the training set was established: Not applicable.

    Summary based on the provided document:

    The GE ViewPoint system is described as a software-based medical image management system designed to accept, transfer, display, store, and process ultrasound images and data. It allows for measurement, calculation, annotation, and preparation/printing of patient examination reports.

    The manufacturer asserts that the device is substantially equivalent to the KinetDx® Diagnostic Workstation for Radiology (K041029). The basis for this equivalence is stated to be:

    • Equivalent technological characteristics
    • Key safety and effectiveness features
    • Physical design, construction, and materials
    • Essentially the same intended uses

    The submission highlights non-clinical tests for conformance to design specifications and software development, and system compatibility. It also mentions an evaluation in a clinical setting "to help assure reliability and compatibility within the intended network environment," but explicitly states that clinical tests were "None required to confirm safety and effectiveness."

    Therefore, the document relies on the concept of substantial equivalence to a legally marketed predicate device rather than demonstrating performance against specific acceptance criteria through a detailed study.