510(k) Data Aggregation

    K Number
    K052805

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-10-17

    (13 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K040596,K050326,K051308

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows: Cardiac, Transesophageal, Peripheral Vascular, Neonatal Cephalic, Adult Cephalic, Small organ, Musculoskeletal (Conventional and Superficial), Abdominal, Fetal, Transvaginal, Transrectal, Pediatric and Intraoperative Abdominal. For Model 6150 (MyLab70), Urological is also included.

    Device Description

    The 7300 (MyLab30), 7350 (MyLab50) and 6150 (MyLab70) system designs remain the same as those previously cleared by FDA via K040596, K050326, and K051308, respectively. They are compact ultrasound systems used to perform diagnostic general ultrasound studies. Their primary modes of operation are: B-Mode, M-Mode, Doppler and Color Flow Mapping and, on lower frequency probes, Tissue Enhancement Imaging (TEI). The systems are equipped with an LCD Color Display and can drive phased (PA), convex (CA) and linear array (LA) and Doppler probes.

    AI/ML Overview

    The provided 510(k) summary for the MyLab30, 50, 70 Systems from Esaote, S.p.A. is a premarket notification for a diagnostic ultrasound imaging system. It establishes substantial equivalence to previously cleared predicate devices.

    This document does not contain information about specific acceptance criteria, a study proving device performance against those criteria, sample sizes for test or training sets, expert qualifications, adjudication methods, multi-reader multi-case studies, or standalone algorithm performance data.

    The document is a regulatory submission for a medical device that outlines its intended use, describes the device, references predicate devices, and lists requested new indications for various transducers and systems. It primarily focuses on showing that the new device (or updates to existing devices) is substantially equivalent to legally marketed predicate devices, as required by the FDA 510(k) process.

    Therefore, I cannot fulfill the request to provide a table of acceptance criteria and reported device performance or details about a study that proves the device meets those criteria, as this information is not present in the provided text.

    Based on the available information:

    1. Table of Acceptance Criteria and Reported Device Performance: Not available in the provided text.
    2. Sample Sizes and Data Provenance (Test Set): Not available in the provided text.
    3. Number and Qualifications of Experts (Ground Truth for Test Set): Not available in the provided text.
    4. Adjudication Method (Test Set): Not available in the provided text.
    5. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study: Not available in the provided text.
    6. Standalone (Algorithm Only) Performance Study: Not applicable or not available in the provided text, as this is an ultrasound system, not an AI algorithm.
    7. Type of Ground Truth Used: Not available in the provided text.
    8. Sample Size for Training Set: Not applicable or not available in the provided text, as this is an ultrasound system, not an AI algorithm requiring a training set in the conventional sense.
    9. How Ground Truth for Training Set was Established: Not applicable or not available in the provided text.

    The document primarily focuses on:

    • Device Description: The MyLab30, MyLab50, and MyLab70 are compact/mainframe ultrasound systems for diagnostic general ultrasound studies, including various clinical applications (Cardiac, Peripheral Vascular, Abdominal, Fetal, etc.). They operate in B-Mode, M-Mode, Doppler, Color Flow Mapping, and Tissue Enhancement Imaging (TEI).
    • Predicate Devices: K040596 (MyLab30), K050326 (MyLab50), K051308 (MyLab70), and K051837 (MyLab90).
    • New Indications/Features: The submission adds specific probes (2.0 CW, 5.0 CW Doppler Probes, IOE323 probe), Biopsy Attachment (ABS15), VPAN, Compound Imaging, and for some models, Intelligent Real Time Processing, and an "Intraoperative Abdominal" indication for use across various modes with specified transducers. The forms indicate "N" (new indication) for certain clinical applications and modes for the new IOE323, 2 CW, and 5 CW transducers, confirming these as the newly sought clearances.
    • Regulatory Compliance: The systems are manufactured under ISO 9001:2000 and ISO 13485 certified quality system. The FDA letter grants substantial equivalence subject to a post-clearance special report containing acoustic output measurements based on production line devices.
    Ask a Question

    Ask a specific question about this device

    K Number
    K050326

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-02-28

    (19 days)

    Product Code
    Regulation Number
    892.1550
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K982444,K994369,K040596

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows: Cardiac, Transesophageal, Peripheral Vascular, Neonatal Cephalic, Small organ, Musculoskeletal (Conventional and Superficial), Abdominal, Fetal, Transvaginal, Transrectal and Pediatric.

    Device Description

    The 7350 is a mainframe ultrasound system used to perform diagnostic general The 7500 is a first framimary modes of operation are: B-Mode, M-Mode, Doppler and Color Flow Mapping and, on lower frequency probes, Tissue Enhancement Imaging (TEI). The 7350 is equipped with a CRT Color Display. The full alphanumeric keyboard (1121). The plete on-screen data entry of patient information and on-screen annotations. The 7350 can drive phased (PA), convex (CA) and linear array (LA) probes. The 7350 is equipped with a CD-RW disk drive that can be used for image storage. Data can also be stored directly to a Personal Computer via a LAN port. Optional accessory devices available for the 7350 include an S-VHS video recorder; a monochrome or color page printer. The 7350 is equipped with an isolation transformer to adequately insulate the system's peripherals.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and study information for the Esaote 7350 Ultrasound Imaging System (K050326), based on the provided 510(k) summary:

    This 510(k) summary focuses on establishing substantial equivalence to predicate devices rather than providing detailed clinical study results with specific performance metrics and acceptance criteria in the way a novel AI/CADe device submission might. Therefore, many of the requested fields will be marked as "Not Applicable" or "Not Provided" based on the content. The acceptance criteria here largely refer to meeting the same technological characteristics and intended uses as the predicate devices, and demonstrating safety and effectiveness as an ultrasound imaging system.


    Acceptance Criteria and Device Performance for Esaote 7350 Ultrasound Imaging System (K050326)

    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance Criteria (based on predicate device characteristics and safety standards)Reported Device Performance (Esaote 7350)
    Electrical Safety: Compliance with IEC60601-1Complies with IEC60601-1
    Ultrasound Safety: Track 3 (Acoustic Output Display)Track 3 (Acoustic Output Display)
    Intended Use Equivalence: Covers specified clinical applicationsCovers all specified clinical applications (Cardiac, Fetal, Abdominal, Pediatric, etc.)
    (See detailed list of "new indications" and previously cleared indications in the document)
    Probe Technology Equivalence: Supports Phased Array, Linear Array, Convex ArraySupports Phased Array, Linear Array, Convex Array
    Operating Modes Equivalence: Supports 2D, M-Mode, PW, CW, CFM, Amplitude Doppler, TEISupports 2D, M-Mode, PW, CW, CFM, Amplitude Doppler, TEI
    Imaging Frequencies Equivalence: Supports 2.0-10 MHzSupports 2.0, 2.5, 3.5, 5.0, 7.5, 10 MHz
    CFM/Doppler Frequencies Equivalence: Supports specified rangeSupports 2.0, 2.5, 3.3, 5.0, 6.6, 8.0 MHz (broader than some predicates)
    Tissue Velocity Mapping feature: If present in predicate, expected hereYES (present, similar to 7300, but not Megas)
    Biopsy Guidance Equivalence: Supports specified uses and markersSupports General Purpose, Transrectal, Transvaginal with 1 cm line depth marker
    Display Characteristics Equivalence: SVGA standardSVGA standard (uses CRT vs. LCD on 7300, but still SVGA)
    Digital Archival Capabilities: YESYES (CD-RW, LAN port, DICOM classes)
    VCR / Page Printer Support: YESYES
    M&A Capabilities Equivalence: Cardiac, Vascular, OB, general purposeCardiac, Vascular, OB, general purpose measurements

    2. Sample Size Used for the Test Set and Data Provenance

    The provided document is a 510(k) summary for an ultrasound imaging system. It primarily establishes substantial equivalence based on technical specifications and intended uses compared to predicate devices. It does not contain information about a clinical test set with patient data (images) in the way that an AI/CADe device submission would. The "performance" assessment here relates to the system's ability to operate according to its specifications and perform the listed imaging modes for various clinical applications, which is typically verified through engineering testing, compliance with standards, and comparison to existing cleared devices.

    Therefore:

    • Sample Size for Test Set: Not applicable or not provided. This type of device typically undergoes extensive bench testing, phantom studies, and possibly limited clinical evaluations for image quality and functionality, but not a "test set" of patient data for diagnostic accuracy in the context of AI.
    • Data Provenance (Country of Origin, Retrospective/Prospective): Not applicable or not provided.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Number of Experts: Not applicable. The "ground truth" for an ultrasound system of this nature is its ability to produce diagnostically acceptable images for various applications and its compliance with safety and performance standards. This is assessed through technical verification and validation, not by expert interpretation of a specific test set.
    • Qualifications of Experts: Not applicable.

    4. Adjudication Method for the Test Set

    • Adjudication Method: Not applicable. There is no mention of an adjudication process for a test set of images.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done

    • MRMC Study: No. This is a submission for a general ultrasound imaging system, not an AI/CADe tool, so an MRMC study comparing human readers with and without AI assistance is not relevant or expected for this type of device.
    • Effect size of human readers improving with AI vs without AI assistance: Not applicable.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    • Standalone Study: Not applicable. This device is an imaging system, not an algorithm, so the concept of standalone performance does not apply.

    7. The Type of Ground Truth Used

    • Type of Ground Truth: For this type of device, the "ground truth" is derived from:
      • Technical Specifications and Standards Compliance: Meeting electromagnetic compatibility, acoustic output limits (IEC60601-1, Track 3 Acoustic Output Display), and electrical safety standards.
      • Predicate Device Equivalence: Demonstrating that the new device has substantially equivalent technological characteristics and intended uses to previously cleared (predicate) ultrasound systems.
      • Image Quality Assessment: Verification that the system produces images of diagnostic quality across its intended applications and modes, likely through phantom studies and internal clinical evaluation by ultrasound specialists, but without a formal external "ground truth" per se in the context of a diagnostic accuracy study.

    8. The Sample Size for the Training Set

    • Sample Size for Training Set: Not applicable. This is not an AI/CADe device that relies on a "training set" of data.

    9. How the Ground Truth for the Training Set Was Established

    • How Ground Truth Was Established (for Training Set): Not applicable.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1