Found 2 results

510(k) Data Aggregation

    K Number
    K151404

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2016-02-12

    (262 days)

    Product Code
    Regulation Number
    868.5800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K944451, K013728, K022125

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    ProTrach DualCare is a combined Speaking Valve and Heat and Moisture Exchanger (HME) intended for spontaneously breathing tracheostomized patients using a tracheostomy tube with a deflated cuff, or a tracheostomy tube without cuff.

    In HME-mode the device conditions inhaled air by retaining heat and moisture from the exhaled air.

    By turning the lid of the Speaking Valve into speaking mode air is re-directed to enable speech.

    The entire device is for single patient use and the HME-part is for single use.

    Patient Population: For spontaneously breathing tracheostomized patients (adults and pediatric patients greater than 10kg in weight) using a tracheostomy tube with a deflated cuff, or a tracheostomy tube without cuff.

    Environment of Use: Hospitals, ICU, sub-acute care institutions and home.

    Device Description

    The Speaking Valve, the HME DigiTop and the HME DigiTop O2 (sold separately) are all used to enable speaking. They will therefore be referenced to as "speaking devices".

    Speaking Valve and HME 15 / 22

    The reusable Speaking Valve is used with a single use 15 mm or 22 mm Heat and Moisture Exchanger (HME). The HME is placed so that it prevents direct contact between the Speaking Valve and the airways. This prevents the Speaking Valve from being clogged or soiled by mucus.

    The Speaking Valve has two modes: speaking mode and HME mode.

    In speaking mode, a flexible membrane is positioned in the airflow openings and acts as a one way valve. It opens during inhalation so the patient can inhale through the device. During exhalation, the membrane remains closed and the air is re-directed through the upper airways and the vocal folds. Thereby the patient is able to speak. In speaking mode the inhaled air does not get conditioned since the exhaled air goes out through the upper airways.

    In HME mode the membrane is moved out of the airflow so that the patient both inhales and exhales through the device. The inhaled air is conditioned by the heat and moisture that is retained from the exhaled air in the impregnated HME mode, speaking is not possible. The device is switched between the modes by rotating the lid of the Speaking Valve until it clicks into the desired position.

    HME DigiTop and HME DigiTop O2

    The HME DigiTop and the HME DigiTop O2 enable use of the HME without the Speaking Valve, and can manually be occluded to enable speaking.

    AI/ML Overview

    The provided text is a Premarket Notification (510(k)) for a medical device called "ProTrach DualCare." This document is a regulatory submission to the FDA demonstrating that the new device is substantially equivalent to legally marketed predicate devices. It focuses on comparing the new device to existing ones and presenting non-clinical studies to support safety and performance.

    The document does not contain information about studies involving human subjects, clinical efficacy, or the statistical metrics often associated with AI/ML device performance (like sensitivity, specificity, AUC) from a test set with corresponding ground truth established by experts. Therefore, many of the requested items cannot be directly extracted from this document.

    However, I can extract information related to the device's technical specifications and the non-clinical testing performed to establish its performance and substantial equivalence.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document provides a comparison table between the ProTrach DualCare and its predicate device (SPIRO Speaking Valve) for several performance attributes. While explicit "acceptance criteria" (numerical thresholds) are not always stated, the comparison implies that "same" or "better" performance is the acceptance criterion for substantial equivalence.

    Acceptance Criteria (Implied)ProTrach DualCare Performance (Reported)
    Moisture Loss: Better than 28 mgH2O/l airHME 15 Regular: 22 mgH2O/l air (Better)
    HME 15 XtraMoist: 20 mgH2O/l air (Better)
    HME 22: 21 mgH2O/l air (Better)
    Dead Space: Less than 5.6 mlHME 15 Regular: 4.05 ml (Less)
    HME 15 XtraMoist: 4.05 ml (Less)
    HME 22: 4.62 ml (Less)
    Attachment and Detachment forces: AcceptableVerified
    Durability of devices: AcceptableVerified
    Simulated use: AcceptableVerified
    Warning label durability: AcceptableVerified
    Function after drop test: AcceptableVerified
    Function after climate testing: AcceptableVerified
    Function after aging: AcceptableVerified
    Function after transport: AcceptableVerified
    Biocompatibility (cytotoxicity, sensitization, intracutaneous reactivity, acute systemic toxicity, genotoxicity, Leachables & Extractables): AcceptableAcceptable results (in accordance with ISO 10993 series)
    Risk management (ISO 14971): CompliantConducted
    Usability (simulated use testing): AcceptableConducted

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    This information is not provided in the document. The studies mentioned are primarily non-clinical engineering and biocompatibility tests. There is no mention of "test sets" in the context of clinical data or human subjects.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This information is not provided as the document does not describe studies involving expert-established ground truth for a clinical test set. The ground truth for the non-clinical tests (e.g., moisture loss, dead space) would be established by the measurement instruments and methodology prescribed by relevant engineering standards.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This information is not provided as there is no mention of a human-reviewed "test set" and thus no need for an adjudication method.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    An MRMC comparative effectiveness study was not done. This submission is for a physical medical device (speaking valve/HME) and does not involve AI or human readers.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This is not applicable as the device is not an AI algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    For the non-clinical tests: The "ground truth" for reported performance metrics like moisture loss, airflow resistance, leakage, and dead space would be derived from standardized physical measurements using laboratory equipment, following recognized testing standards (e.g., those related to HMEs and tracheostomy accessories). For biocompatibility, the ground truth is established by the results of biological tests according to ISO 10993 series.

    8. The sample size for the training set

    This information is not applicable/not provided. This device does not use a "training set" in the context of AI/ML.

    9. How the ground truth for the training set was established

    This information is not applicable/not provided.

    Ask a Question

    Ask a specific question about this device

    K Number
    K072582

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-05-30

    (260 days)

    Product Code
    Regulation Number
    868.5800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K014102, K022125

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Provox® Micron HME™ is a specialized stoma cover that acts as a heat and moisture exchanger (HME) and air filtration device for laryngectomized patients. Provox® Micron HMETM partially restores lost breathing resistance due to laryngectomy.

    For patients with a voice prosthesis or surgical speech fistula it may also facilitate voicing.

    It is intended to be used with the Provox® HME System.

    Environments of use include - hospitals, sub-acute care institutions and home.

    Device Description

    The Provox® Micron HME™ is a device which covers the stoma of a laryngectomy pationt. It is dcsigned to heat and humidify inhaled air to reduce the drying out of the airway as well as it incorporates filter media to filter the inhaled air of bacteria, virus and particulate matter.

    It also incorporates a feature whereby the user may close the device, diverting exhaled air through the esophagus to facilitate voicing. This feature is identical to the predicate, Provox® HME cassette (K014102) and Provox® FreeHands HME (K022125), the only difference between the proposed device and the predicates in the addition of filter media.

    AI/ML Overview

    Here's an analysis of the acceptance criteria and the study information for the Provox® Micron HME™ device, based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    SpecificationAcceptance Criteria (Predicate Performance)Reported Device Performance (Provox® Micron HME™)
    HME function (Moisture loss)23.7 mg H₂O / L (K014102)22 mg H₂O / L
    Filtration BFE/VFE (Per ASTM F2101)BFE - 99.98% / Viral - 99.9% (K043120 - Uni-Filter)BFE ->99.8% / VFE ->99.8%
    Pressure drop (cm H₂O) @ 30 Lpm0.9 cm H₂O @ 30 Lpm (K014102)0.7 cm H₂O @ 30 Lpm
    Pressure drop (cm H₂O) @ 60 Lpm2.11 cm H₂O @ 60 Lpm (K014102)1.9 cm H₂O @ 60 Lpm

    2. Sample size used for the test set and the data provenance

    The provided text does not contain details about specific test set sample sizes or data provenance (e.g., country of origin, retrospective/prospective) for the performance evaluations. The performance metrics listed are presented as single values, likely representing the results of a conducted test or series of tests, but the methodology and sample size for these tests are not described in this summary. The document focuses on demonstrating substantial equivalence to predicates through comparison of specifications.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not applicable to the data provided. The performance metrics (moisture loss, filtration efficiency, pressure drop) are objective measurements typically determined through laboratory testing according to established standards (e.g., ISO 9360, ASTM F2101), not through expert consensus or interpretation of subjective data requiring ground truth establishment by human experts.

    4. Adjudication method for the test set

    This information is not applicable as the performance metrics are objective measurements, not subjective evaluations requiring adjudication.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This information is not applicable. The device is a medical device (HME and filter for laryngectomized patients), not an AI-powered diagnostic or interpretive tool that would involve human readers or AI assistance in the way described.

    6. If a standalone (i.e. algorithm only without human-in-the loop performance) was done

    This information is not applicable. The device is a physical medical device, not an algorithm.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the reported performance metrics would be laboratory measurements conforming to established international standards.

    • HME function (Moisture loss): Measured according to ISO 9360.
    • Filtration BFE/VFE: Measured according to ASTM F2101.
    • Pressure drop: Measured under controlled airflow conditions.
      These standards define the precise methodology and equipment for obtaining these objective measurements.

    8. The sample size for the training set

    This information is not applicable. The Provox® Micron HME™ is a physical medical device, not a machine learning model that requires a training set.

    9. How the ground truth for the training set was established

    This information is not applicable for the same reason as #8.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1