    Intended Use

    DePuy Synthes MatrixWAVE MMF System (originally cleared per K141165)
    The DePuy Synthes MatrixWAVE MMF System is indicated for the temporary treatment of mandibular and maxillary fractures and osteotomies in adults and adolescents (age 12 and higher) in whom permanent teeth have erupted.

    DePuy Synthes MatrixMANDIBLE Plate and Screw System (originally cleared per K121574)
    The DePuy Synthes MatrixMANDIBLE Plate and Screw System is intended for oral, maxillofacial surgery:

    • Trauma
    • Reconstructive surgery
    • Orthognathic surgery (surgical correction of dentofacial deformities)

    DePuy Synthes MatrixMANDIBLE Plate and Screw System (originally cleared per K113567)
    The DePuy Synthes MatrixMANDIBLE Plate and Screw System is intended for oral, maxillofacial surgery:

    • Trauma
    • Reconstructive surgery
    • Orthognathic surgery (surgical correction of dentofacial deformities)

    DePuy Synthes Dentoalveolar Bone Fixation System (originally cleared per K102656)
    The DePuy Synthes Dentoalveolar Bone Fixation System is intended for use in non-load bearing applications for maintaining the relative position of and/or containing bony fragments, bone grafts (autograft or allograft), or bone graft substitutes in reconstruction of maxillary and/or mandibular areas, including the dentoalveolar ridge.

    DePuy Synthes MatrixMANDIBLE Subcondylar Plates (originally cleared per K091233)
    The DePuy Synthes MatrixMANDIBLE Subcondylar Plates are intended for oral, maxillofacial surgery; trauma and reconstructive surgery, specifically for fractures of the subcondylar region of the mandible and fractures of the condylar basis region of the mandible.

    DePuy Synthes MatrixMANDIBLE Preformed Reconstruction Plates (originally cleared per K091144)
    The DePuy Synthes MatrixMANDIBLE Preformed Reconstruction Plates are intended for use in oral and maxillofacial surgery, trauma and reconstructive surgery. This includes primary mandibular reconstruction, comminuted fractures and temporary bridging pending delayed secondary reconstruction, including fractures of edentulous and/or atrophic mandibles, as well as unstable fractures.

    DePuy Synthes MatrixORTHOGNATHIC Plating System (originally cleared per K083388)
    The DePuy Synthes MatrixORTHOGNATHIC Plating System is intended for use in selective trauma of the midface and maxillofacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla, mandible and chin in adolescents (greater than 12 to 21 years of age) and adults. Specific Indications for Use:

    • Fractures of the midface and maxillofacial skeleton
    • LeFort I osteotomies, sagittal split osteotomies and genioplasties
    • Orthognathic surgery including reconstructive procedures

    DePuy Synthes MatrixMANDIBLE Plate and Screw System (originally cleared per K082335)
    The DePuy Synthes MatrixMANDIBLE Plate and Screw System is intended for oral, maxillofacial surgery; trauma; reconstructive surgery; and orthognathic surgery (surgical correction of dentofacial deformities).

    DePuy Synthes Craniofacial Plate and Screw System (originally cleared per K080331)
    The DePuy Synthes Craniofacial Plate and Screw System is intended for use in selective trauma of the midface and maxillofacial skeleton, maxillofacial surgery, reconstructive procedures and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes MatrixMANDIBLE Plate and Screw System (originally cleared per K063790)
    The DePuy Synthes MatrixMANDIBLE Plate and Screw System is intended for oral, maxillofacial surgery; trauma; reconstructive surgery; and orthognathic surgery (surgical correction of dentofacial deformities).

    DePuy Synthes Craniofacial Plate and Screw System (originally cleared per K050608)
    The DePuy Synthes Craniofacial Plate and Screw System is intended for use in selective trauma of the midface and maxillofacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes Neuro Plate and Screw System (originally cleared per K042365)
    The DePuy Synthes Neuro Plate and Screw System is intended for use in selective trauma of the midface and maxillofacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes 1.3 & 1.5 mm Contourable Titanium (Ti.) Mesh Plates (originally cleared per K033121)
    The DePuy Synthes 1.3 & 1.5 mm Contourable Titanium (Ti.) Mesh Plates are intended for use in selective trauma of the midface and maxillofacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes Orbital Plates (originally cleared per K031761)
    The DePuy Synthes Orbital Plates are intended for use in selective trauma of the midface and maxillofacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes Low Profile Neuro System (originally cleared per K022012)
    The DePuy Synthes Low Profile Neuro System is intended for use in selective trauma of the midfacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes Midface Distractor (Originally cleared per K022005)
    The DePuy Synthes Midface Distractor is intended for use in adult and pediatic populations for the treatment of midface conditions for which reconstructive osteotomy and segment are indicated. This includes conditions such as midfacial retrusion. The device is intended to provide temporary stabilization and gradual lengthening of the midfacial bones.

    DePuy Synthes Translating Maxillary Distractor (Originally cleared per K020505)
    The DePuy Synthes Translating Maxillary Distractor is intended for use in maxillofacial surgery, reconstructive procedures, and selective orthognathic surgery of the maxilla. Specifically it is intended for distraction of the maxilla utilizing a LeFort I osteotomy in adult and pediatric populations.

    DePuy Synthes Midface Distractor (Originally cleared per K010499)
    The DePuy Synthes Midface Distractor is intended for use in adult and pediatic populations for the treatment of midface conditions for which reconstructive osteotomy and segment are indicated. This includes conditions such as midfacial retrusion. The device is intended to provide temporary stabilization and gradual lengthening of the midfacial bones.

    DePuy Synthes Maxillary Distractor (Originally cleared per K003393)
    The DePuy Synthes Maxillary Distractor is intended for use in maxillofacial surgery, reconstructive procedures, and selective orthognathic surgery of the maxilla. Specifically it is intended for distraction of the maxilla utilizing a LeFort I osteotomy in adult and pediatric populations.

    DePuy Synthes Orbital Mesh Plates (Originally cleared per K001311)
    The DePuy Synthes Orbital Mesh Plates for the Midfacial System are indicated for selective trauma of the midface and maxillofacial skeleton; maxillofacial surgery; reconstructive procedures; and selective orthognathic surgery of the maxilla and chin.

    DePuy Synthes 2.0 mm Locking Plate System (2.0 LPS) (originally cleared per K974555)
    The DePuy Synthes 2.0 LPS is intended for oral, maxillofacial surgery: trauma; reconstructive surgery; and orthognathic surgery (surgical correction of dentofacial deformities).

    DePuy Synthes 2.4 mm Universal Locking Plate System (originally cleared per K961421)
    The DePuy Synthes 2.4 mm Universal Locking Plate and screw system, that is intended for mandible trauma and reconstruction procedures.

    DePuy Synthes Mandibular Modular Fixation System (originally cleared per K954385)
    The DePuy Synthes Mandibular Modular Fixation System is a plate and screw system, manufactured from commercially pure titanium, and is intended for use in:

    • Oral, maxillofacial surgery: trauma; surgical correction of dentofacial deformities; reconstructive surgery; and maxillofacial surgery

    DePuy Synthes Maxillofacial Titanium Micro Set (originally cleared per K912932)
    General indications:

    • Maxillofacial surgery
    Device Description

    DePuy Synthes MatrixWAVE MMF is a bone-borne maxillomandibular fixation (MMF) system that consists of wave shaped plates (made from commercially pure Titanium) that are attached to the dental arches with self-drilling locking screws (made from Titanium alloy, Ti-6Al-7Nb). The system is intended for temporary stabilization of mandibular and maxillary fractures and osteotomies to maintain proper occlusion during intraoperative bone fixation and postoperative bone healing (approximately 6-8 weeks). The dental arches are brought into occlusion by wiring around the plate hooks and/or accessible screw heads.

    The DePuy Synthes MatrixMANDIBLE Plate and Screw System consists of a variety of plates offered in multiple shapes and a variety of screws offered in multiple diameters and lengths to meet the anatomical needs of the patient. System implants are manufactured in either titanium or titanium alloy and are intended for single use only. The DePuy Synthes MatrixMANDIBLE screws that are the subject of this premarket notification are made from titanium alloy (Ti-6A1-7Nb) and are available in a diameter of 2.0 mm and lengths ranging from 4 mm to 8 mm, and have a thread pitch of 0.5 mm. These screws work with all plates within the DePuy Synthes MatrixMANDIBLE Plate and Screw System. These devices are offered, non-sterile and must be sterilized prior to use. DePuy Synthes MatrixMANDLBLE screws are intended for single use.

    The DePuy Synthes MatrixMANDIBLE Plate and Screw System consists of a variety of plates offered in multiple shapes and a variety of screws offered in multiple diameters and lengths to meet the anatomical needs of the patient. This submission pertains to 1.5 mm thick MatrixMANDIBLE Reconstruction Plates, which are available as left and right single angle reconstruction plates and in three sizes of double angle reconstruction plates. These plates are made from pure titanium and may be offered sterile or non-sterile (non-sterile implants must be sterilized prior to use). DePuy Synthes MatrixMANDIBLE 1.5 mm thick reconstruction plates are intended for single use only.

    The DePuy Synthes Dentoalveolar Bone Fixation System is a plate, mesh, and screw system intended to be implanted intraorally for use in non-load bearing applications for maintaining the relative position of and/or containing bony fragments, bone grafts (autograft or allograft), or bone graft substitutes in reconstruction of maxillary and/or mandibular areas, including the dentoalveolar ridge. Screws: The System includes 1.3 mm, 1.5 mm, and 2.0 mm diameter cortex screws in lengths from 3 mm to 20 mm. Screws are offered with both self-tapping and self drilling tips. Screws are manufactured from titanium alloy (Ti-6A1-7Nb). Plates and Meshes: The System includes plates and meshes that come in a variety of configurations to accommodate various dentoalveolar defect sites. The plates attach to bone via titanium cortex screws. Plates and meshes are manufactured from commercially pure titanium.

    The DePuy Synthes MatrixMANDIBLE Subcondylar Plates are designed specifically to match the anatomy of the subcondylar region of the mandible. These plates are designed for use with DePuy Synthes MatrixMANDIBLE screws that come in multiple diameters and lengths to meet the anatomical needs of the patient. System components are manufactured in either titanium or titanium alloy and are intended for single use only.

    The DePuy Synthes MatrixMANDIBLE Preformed Reconstruction Plates are anatomically contoured to match the body and angle regions of the mandible in most patients. These plates are designed for use with DePuy Synthes MatrixMANDIBLE screws that come in multiple diameters and lengths to meet the anatomical needs of the patient. System components are manufactured in either titanium alloy and are intended for single use only.

    The DePuy Synthes MatrixORTHOGNATHIC Plating System consists of a variety of plates that come in a variety of shapes and sizes to meet the anatomical needs of the patient. This system is designed for use with DePuy Synthes Matrix screws. System components are manufactured in either titanium or titanium alloy and are intended for single use only.

    The DePuy Synthes MatrixMANDIBLE Plate and Screw System incorporates small, medium and large plates designed so all plates accept all system screws. The plates are available in various shapes and thicknesses and accept self-tapping and self-drilling cortex and locking screws. The implants are manufactured from titanium.

    The DePuy Synthes Orbital Plates, components of the Synthes Craniofacial Plate and Screw System, consist of anatomically shaped orbital plates that come in various sizes and configurations to fit the patient anatomy. These devices are designed for use with DePuy Synthes craniofacial bone screws commercially available in the U.S. System components are manufactured in titanium and are intended for single use only.

    The DePuy Synthes MatrixMANDIBLE Plate and Screw System is the next generation of Synthes (USA) fixation systems for the mandible. The system incorporates small, medium, and large plates designed so that all plates accept all system screws. The plates are available in various shapes and thicknesses, and accept self-tapping cortex and locking screws. The implants are manufactured from CP titanium and titanium alloy.

    The DePuy Synthes Craniofacial Plate and Screw System consist of plates and meshes that come in a variety of shapes and sizes to meet the anatomical needs of the patient. This system is designed for use with 1.8 mm screws and 2.1 mm emergency screws. The screws will be used with Synthes 1.8 mm hexagonal screwdriver blades. System components are manufactured in either titanium or titanium alloy and are intended for single use only.

    DePuy Synthes Neuro Plate and Screw System consists of plates, burr hole covers, and meshes that come in a variety of shapes and sizes to meet the anatomical needs of the patient. This system is designed for use with 1.8 mm screws and 2.1 mm emergency screws. The screws will be used with Synthes 1.8 mm hexagonal screwdriver blades. System components are manufactured in either titanium or titanium alloy and are intended for single use only.

    The DePuy Synthes 1.3 & 1.5 mm Contourable Ti. Mesh Plates come in a variety of shapes and sizes to meet the anatomical need of the patient. The plates are sterile and for single use only.

    The DePuy Synthes Orbital Plates come in a variety of shapes and sizes to meet the anatomical need of the patient. The plates are sterile/non-sterile and for single use only.

    The DePuy Synthes Low Profile Neuro System consists of titaniurn plates, meshes, and screws in a variety of shapes and sizes designed for various maxillofacial procedures.

    The DePuy Synthes Midface Distractor is a maxillofacial distraction device consisting of two telescoping components with attached footplates. The device is intended to be placed subcutaneously with an anterior footplate fastened to the lateral orbital rim, extending down to the maxilla and spanning the zygomaticomaxillary suture; and a posterior footplate fastened to the temporal region of the cranium. The plates are fixed to the bone through unthreaded screw holes using 1.5 mm or 2.0 mm Cortex screws.

    The DePuy Synthes Translating Maxillary Distractor is an intra-oral distraction device. It features a distractor body with two adjustable footplate components, each with contourable legs having screw holes that are fixed to the bone via 2.0 mm or 2.4 mm cortex screws.

    The DePuy Synthes Midface Distractor is a maxillofacial distraction device consisting of two telescoping components with attached footplates. The device is intended to be placed subcutaneously with an anterior footplate fastened to the lateral orbital rim, extending down to the maxilla and spanning the zygomaticomaxillary suture; and a posterior footplate fastened to the temporal region of the cranium. The plates are fixed to the bone through unthreaded screw holes using 1.5 mm or 2.0 mm Cortex screws.

    The DePuy Synthes Maxillary Distractor is an intra-oral distraction device. It features two telescoping components, with contourable legs having screw holes, that are fixed to the bone via 2.0 mm or 2.4 mm cortex screws.

    The DePuy Synthes Orbital Mesh Plates have a semi-circular shape with a radially designed mesh pattern. Orbital Mesh Plates are available in 0.2, 0.3 and 0.4 mm profile thickness. Standard 1.0 mm screw holes positioned along the outer arc of the Orbital Mesh Plate accept 1.0 mm selftapping bone screws and 1.2 mm emergency screws. Synthes Orbital Mesh Plates for the Midfacial System are provided nonsterile.

    The DePuy Synthes 2.0 Locking Plate System consists of five different types of plates and two screws, as follows: 2.0 Straight Locking Plates, 2.0 Crescent Locking Plates, 2.0 Atrophic Locking Plates, 2.0 Reconstruction Locking Plates, 2.0 Specialty Plates (Y- and 1.5 mm and 2.0 mm Self-drilling Locking Screws. The plates feature a threaded screw hole which accepts a locking screw with a mating external thread on the screw head. Engaging these screw threads fixes the screw to the plate thereby reducing the likelihood of screw loosening and improving the screw to plate stability of the implant system.

    The DePuy Synthes 2.4 mm Universal Locking Plate System plates are designed to accept the 2.4 mm – 3.0 mm diameter locking/non-locking screws.

    The DePuy Synthes Mandibular Fixation System is a plate and screw system manufactured from titanium. The plates are available in a variety of shapes and sizes, and attach to bone via 2.0 mm, 2.4 mm or 2.7 mm screws.

    The DePuy Synthes Maxillofacial Titanium Micro set consists of titanium bone plates (shapes include L,Y,H,T, Double-Y, Mesh and Straight) and self-tapping screws.

    AI/ML Overview

    The provided document, K192655, is a 510(k) Premarket Notification for DePuy Synthes Maxillofacial Portfolio - MR Conditional. This type of submission is a declaration from the manufacturer to the FDA that their device is substantially equivalent to a legally marketed predicate device, and it does not typically involve clinical performance studies with acceptance criteria as one would find for novel AI/ML medical devices.

    Instead, the provided document focuses on demonstrating MR Conditional safety for a portfolio of existing maxillofacial bone plates and screw systems that were previously cleared by the FDA. The "acceptance criteria" and "study" described herein relate to non-clinical electromagnetic compatibility (EMC) testing in an MR environment, not clinical performance for diagnostic or therapeutic accuracy of an AI/ML algorithm.

    Therefore, the requested information elements related to AI/ML device performance (e.g., sample size for test set, data provenance, number of experts for ground truth, adjudication methods, MRMC studies, standalone performance, training set details) are not applicable to this specific submission.

    Here's a breakdown of the information that is available and relevant to the document's purpose:


    Acceptance Criteria and Study for MR Conditional Safety (Non-Clinical)

    The submission aims to add "MR Conditional" labeling to a portfolio of maxillofacial devices. This requires demonstrating that the devices are safe for use in a specified MR environment under defined conditions. The "acceptance criteria" for this type of submission are typically based on recognized international consensus standards for testing the MR compatibility of medical devices.

    1. Table of Acceptance Criteria and Reported Device Performance

    The document consistently references the following ASTM standards for non-clinical testing to support MR Conditional safety across all listed devices:

    Acceptance Criteria (based on ASTM Standards)Reported Device Performance (Summary)
    Magnetically Induced Displacement Force: (ASTM F2052-14)Non-clinical testing was conducted to assess magnetically induced displacement force.
    Magnetically Induced Torque: (ASTM F2213-06)Non-clinical testing was conducted to assess magnetically induced torque.
    Radiofrequency (RF) Heating: (ASTM F2182-11a)Non-clinical testing was conducted to assess radio frequency (RF) heating. The DUKE model was used for clinically relevant anatomic positioning, and DUKE results will be used for labeling of RF heating.
    Image Artifacts: (ASTM F2119-07)Non-clinical testing was conducted to assess image artifacts.

    Note: The document states that "Non-clinical testing is provided to support the conditional safety..." for each of these parameters. While it doesn't provide specific quantitative results (e.g., exact temperature rise in °C, or N/A for displacement/torque if deemed safe), the acceptance of the 510(k) by the FDA implies that the results of these tests met the predefined safety thresholds for an MR Conditional designation as per the referenced ASTM standards. The specific numerical results (e.g., maximum temperature rises, displacement forces, etc.) would be detailed in the full test reports submitted to the FDA, which are not part of this public summary.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: For non-clinical MR compatibility testing, the "sample size" refers to the number of device units tested. The document does not specify the exact number of physical devices or models tested for each parameter. However, standard practice for such assessments involves testing representative samples of each device type (plates, screws, meshes, distractors) and material compositions (titanium, titanium alloy) to ensure the portfolio's MR safety.
    • Data Provenance: The data is "non-clinical testing" conducted by the manufacturer (Synthes - DePuy Synthes). The country of origin for the testing itself is not explicitly stated in this summary, but it would typically be conducted in a laboratory setting compliant with relevant international standards. This is retrospective in the sense that the studies were performed specifically to characterize the existing devices for MR compatibility.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of those Experts

    • Not Applicable. This is a non-clinical evaluation of physical device properties in an MR environment, not a clinical study involving expert interpretation of medical images or patient outcomes. The "ground truth" for MR safety is established by adherence to recognized ASTM testing standards and the physical properties of the materials and device in situ within the MR scanner, not by human expert consensus or annotations on medical data.

    4. Adjudication Method for the Test Set

    • Not Applicable. As this is non-clinical testing of physical device characteristics, there is no "adjudication" in the sense of resolving discrepancies between human readers or AI outputs. The test results are objective measurements against standard-defined thresholds.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable. This submission is not for an AI-powered device.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    • Not Applicable. This submission is not for an AI-powered device.

    7. The Type of Ground Truth Used

    • Physical Measurements against ASTM Standard Thresholds: The "ground truth" for MR Conditional safety is determined by rigorous physical measurements (e.g., temperature changes, displacement forces, torque, observable image artifacts) obtained through standardized testing protocols (ASTM F2052-14, F2213-06, F2182-11a, F2119-07) and comparison against acceptance limits defined by these standards or applicable regulatory guidance. It's about validating the device's behavior in an MR field, not diagnosing a condition. The "DUKE model" for RF heating indicates a high-fidelity computational human body model used for simulating temperature distributions due to RF fields.

    8. The Sample Size for the Training Set

    • Not Applicable. This is not an AI/ML device. There is no "training set" in the context of machine learning.

    9. How the Ground Truth for the Training Set was Established

    • Not Applicable. As there is no training set for AI/ML, this question doesn't apply.
    Ask a Question

    Ask a specific question about this device

    K Number
    K112557

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-01-05

    (125 days)

    Product Code
    Regulation Number
    882.5320
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    Reference Devices :

    K031659, K983528, K022012, K944561/K944565

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Stryker Universal Neuro 3 System is intended for reconstruction, stabilization and/or rigid fixation of non load-bearing areas subsequent to craniotomy, craniectomy and cranial fractures in adults and adolescents (age 12 and higher).

    Device Description

    The Stryker Universal Neuro 3 System is designed for a wide selection of solutions for cranial fixation. It consists of an implant module (a storage module that contains various versions and shapes of plates and screws) for the respective anatomical and indicated areas. The low profile plates of the Stryker Universal Neuro 3 System provide rigid fixation of cranial flaps with decreased palpability. There is a comprehensive selection of burr hole covers, straight plates, gap plates, 3D-plates, shunt plates, and box plates to provide many fixation options. The malleable plates can be easily contoured by hand without instruments. The pre-shaped skull-base plates provide covers for standard craniectomies, obviating the need to cut or trim mesh.

    AI/ML Overview

    The Stryker Universal Neuro 3 System is intended for reconstruction, stabilization, and/or rigid fixation of non-load-bearing bony areas subsequent to craniotomy, craniectomy, and cranial fractures in adults and adolescents (age 12 and higher).

    Here's an analysis of the provided information regarding acceptance criteria and the study that proves the device meets them:

    1. A table of acceptance criteria and the reported device performance

    Acceptance Criteria CategorySpecific Acceptance CriteriaReported Device Performance
    BiocompatibilityCompliance with ISO 10993-1 (biological evaluation), ISO 10993-12 (sample preparation), ISO 10993-18 (chemical characterization).Materials used are rated biocompatible according to ISO 10993-1. Cytotoxicity testing was performed according to ISO 10993-1, 10993-12, and 10993-18.
    Corrosion ResistanceDemonstrated corrosion resistance of all components.The corrosion resistance of all Neuro 3 screws, plates, and meshes were demonstrated.
    Bending StabilityPlates (GWO) and burr hole covers (GXR) must pass the Lerch test according to ASTM F 382-99.The bending stability of the Universal Neuro 3 plates (GWO) and burr hole covers (GXR) were tested by following ASTM F 382-99. The Lerch test was passed by all plates.
    Screw PerformanceScrews (HBW) must meet ASTM F 543 standards for metallic medical bone screws, including torque, depth, and angle measurements.Testing was performed via ASTM F 543. Torque, depth, and angle were measured. The screws passed the automated insertion test.
    Fixation StabilityScrews must demonstrate pull-out safety.Pull-out safety testing was performed utilizing ASTM F 543. All acceptance criteria were met.
    Retention ForceThe retention force between the screw and the screwdriver blade must meet acceptance criteria.Retention force between the screw and the screwdriver blade was tested utilizing ASTM F 543. All acceptance criteria were met.
    Substantial EquivalenceDemonstrated substantial equivalence to identified predicate devices (Stryker Universal Neuro 2 System, Stryker Micro Dynamic Mesh, Synthes Neuro Plate and Screw System, KLS-Martin Micro Osteosynthesis System).The Stryker Universal Neuro 3 System was verified and validated according to Stryker procedures. It was found substantially equivalent to predicate devices, sharing material composition, operating principles, and similar intended use (with the addition of adolescent use). Minor differences in dimensions and shapes were addressed.

    2. Sample sizes used for the test set and the data provenance

    The document does not specify exact "sample sizes" in terms of number of devices tested for each performance criterion. Instead, it refers to testing of "all plates," "the screws," and "all Neuro 3 screws, plates and meshes." This implies that a sufficient number of samples were tested to demonstrate compliance with the referenced ASTM and ISO standards for the representative product configurations.

    The data provenance is not explicitly stated as "country of origin" or "retrospective/prospective." However, the tests were conducted according to recognized international (ISO) and US (ASTM) standards, suggesting the testing was performed in a controlled laboratory environment to demonstrate compliance. Given the context of a 510(k) submission, this testing would be prospective and specifically conducted for regulatory approval.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This information is not applicable to this type of device and study. The testing for the Stryker Universal Neuro 3 System involves mechanical and material property evaluations against established engineering standards (ASTM, ISO), not clinical assessment requiring expert interpretation of data or images. Therefore, there is no "ground truth" to be established by experts in a clinical sense.

    4. Adjudication method for the test set

    This information is not applicable for the reasons stated above. Adjudication methods are typically used in studies involving subjective interpretation, such as clinical trials or image-based diagnostic assessments.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, if so, what was the effect size of how much human readers improve with AI vs without AI assistance

    There was no MRMC comparative effectiveness study done. This device is a passive implant (craniofacial plates, burr hole covers, and screws) and does not involve AI or human "readers" in its function or evaluation for regulatory submission.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    There was no standalone (algorithm only) performance study done. This device is a physical medical implant and does not involve any algorithms or software for its primary function.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for this device's performance evaluation is based on established engineering standards and material specifications. For example:

    • Biocompatibility: Conformance to ISO 10993 series.
    • Mechanical Properties: Conformance to ASTM F 382-99 for bending stability (Lerch test) and ASTM F 543 for screw performance (torque, depth, angle, pull-out safety, retention force).
    • Material Composition: Commercially Pure Titanium (Grade II, IV) and Titanium Alloy (Grade V), which are well-defined materials with known properties.

    These standards and specifications serve as the objective "ground truth" against which the device's performance is measured.

    8. The sample size for the training set

    There is no training set for this device. As a passive mechanical implant, it does not involve machine learning or AI models that require training data.

    9. How the ground truth for the training set was established

    This question is not applicable as there is no training set or ground truth established for a training set for this device.