Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K021729

    Validate with FDA (Live)

    Date Cleared
    2002-06-21

    (28 days)

    Product Code
    Regulation Number
    876.5010
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    Why did this record match?
    Reference Devices :

    K012066

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Protégé™ Self-expanding Nitinol Stent with StarPort™ Delivery Technology is intended as a palliative treatment of malignant neoplasms in the biliary tree.

    Device Description

    The Protégé™ stent is a self-expanding nitinol (nickel-titanium alloy) stent provided in multiple lengths, (20 - 80 mm) and diameters (6 - 12 mm). The stent is electropolished. The stent is premounted on an 80 or 120 cm working length, 0.035" over-the-wire delivery catheter designed for transhepatic access. Upon deployment, the stent achieves its predetermined diameter and exerts a constant, gentle outward force to establish patency in the biliary ducts. The disposable StarPort Delivery Technology system is comprised of an inner and outer sheath, which are locked together with a safety lock.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification Summary for a medical device, the Protégé™ Self-expanding Nitinol Stent with StarPort™ Delivery Technology (Biliary Indication). It primarily focuses on demonstrating substantial equivalence to a predicate device and outlines the intended use and some regulatory aspects. This document does NOT contain information about specific acceptance criteria or a study that proves the device meets those criteria in the way a clinical trial or performance study report would.

    The document states:

    "The modified Protégé™ Self-expanding Nitinol Stent with StarPort™ Delivery Technology is substantially equivalent to the currently marketed Protégé™ Self-expanding Nitinol Stent with StarPort™ Delivery Technology (K012066) in intended use, materials, technological characteristics and performance. Stent lengths > 80 mm have been added to further expand the product offering."

    This indicates that the manufacturer is claiming equivalence to an already approved device rather than presenting a performance study for this specific modified device against new, defined acceptance criteria. Therefore, most of the requested information regarding acceptance criteria, study details, and ground truth cannot be extracted from this summary.

    Here's what can be inferred or explicitly stated based on the provided text, and what cannot:


    1. Table of Acceptance Criteria and Reported Device Performance

    Acceptance CriteriaReported Device Performance
    Not explicitly defined in the document for the modified device.The modified device is "substantially equivalent" to the predicate device (K012066) in intended use, materials, technological characteristics, and performance. The modification primarily involves adding stent lengths > 80 mm.
    • Reasoning: The summary does not provide specific quantitative acceptance criteria (e.g., success rates, complication rates, patency rates) for the modified stent or a detailed performance report. The entire premise of this 510(k) is to demonstrate substantial equivalence to a legally marketed predicate device rather than fulfilling new, specific performance criteria through a dedicated study.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size: Not applicable / Not mentioned. This document does not describe a clinical performance study with a test set.
    • Data Provenance: Not applicable / Not mentioned. As there's no clinical performance study detailed, there's no data provenance information.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • Not applicable / Not mentioned. No clinical performance study is described with a test set requiring expert ground truth establishment.

    4. Adjudication Method for the Test Set

    • Not applicable / Not mentioned. No clinical performance study is described with a test set requiring an adjudication method.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • Was an MRMC study done? No.
    • Effect size of human readers with AI vs. without AI assistance: Not applicable. This device is a physical medical device (stent), not an AI-powered diagnostic or assistive tool for human readers.

    6. Standalone Performance (Algorithm Only without Human-in-the-Loop Performance)

    • Not applicable. This device is a physical medical device (stent), not an AI algorithm.

    7. Type of Ground Truth Used

    • Not applicable / Not mentioned. No clinical performance study requiring ground truth is described. The basis for approval is substantial equivalence to a predicate device.

    8. Sample Size for the Training Set

    • Not applicable / Not mentioned. This document does not describe a machine learning algorithm or a training set.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable / Not mentioned. This document does not describe a machine learning algorithm or a training set requiring ground truth.

    Conclusion:

    The provided 510(k) Summary pertains to a physical medical device (a biliary stent) and focuses on demonstrating "substantial equivalence" to a previously cleared product. It does not contain information about a dedicated performance study with specific acceptance criteria, test sets, ground truth establishment, or expert involvement as would be found in a clinical trial report for an AI/diagnostic device. The primary "proof" of meeting safety and effectiveness for this submission is its likeness to the predicate device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1