510(k) Data Aggregation

    K Number
    K170366

    Validate with FDA (Live)

    Date Cleared
    2017-06-08

    (122 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Laser Peripherals Laser Fiber is indicated for use in all surgical specialties in which compatible laser systems with operational wavelengths between 500nm – 2200nm have received regulatory clearance. Laser Peripherals surgical fiber optic laser delivery devices are intended for use with any cleared surgical laser with an SMA 905 connector, SMA 906 connector, or manufacturer specific connectors and adaptors.

    Device Description

    The Family of Surgical Laser Fibers are individually packed sterile devices indicated to provide high quality surgical laser fiber optic delivery systems for laser surgery. The Fibers are intended for use in laser surgical procedures including open, laparoscopic ablation, coagulation, incision, and excision or vaporizing in any soft/hard-tissue application for which compatible lasers are applicable. The key components of this system are the SMA-905, SMA-906 and Manufacturer's specific connectors and the Fiber Optic. The fiber optic in the laser fiber is the main component in the assembly and is what allows for delivering the energy to the patient. The fiber portion of the laser fiber is comprised of several different materials; these can be thought of as: 1) the fiber core, 2) fiber cladding and coating layers, and 3) the outside coating or the jacket. All fibers featured in this submission have a core consisting of a silica (glass) material. The core is the main light pipe which offers a path for the light energy. The fiber cladding and coating layers are placed over the core and shield the fiber from losing energy over the length of the fiber and guide the energy to exit the distal tip. The material of the cladding and coating layer has a different index of refraction, which directs the light back into the core. This is typically another layer of silica, but may include a chemical layer (e.g., Fluoropolymer). Fiber selection is based on the ability to transmit the light wavelength that the laser is producing. The outside of the laser fiber is coated with a flexible material to offer abrasion and breakage resistance. This coating is typically an ETFE, but some models offer a Polyimide coating for superior resistance. The distal tip of the laser fiber offers the user an opportunity to configure the output energy to suit the needs of the application. The most predominate distal tip configuration is a flat, polished surface. The flat end face of the fiber allows the energy to exit the fiber unaltered. Other configurations manage the light in different ways. This allows the user to use the fiber where a different method of treatment is appropriate. Fibers can be divided into two categories: Contact and Non-contact. This refers to whether the distal tip is touching the subject matter at the worksite or whether it is held back, away from the target. Contact fibers are generally shaped into configurations intended to maximize the effectiveness of the procedure. These shapes include cone tips, ball tips, spherical tips, etc. A third type of distal tip offers further treatment of the laser energy as it exits the fiber. These distal tips utilize added components to either direct the laser light (i.e., ScatterFree™ (SideFire)) or lens the light (focus or dispersed).

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for "Laser Peripherals, Llc Family Of Bare Laser Fibers." It focuses on demonstrating substantial equivalence to predicate devices rather than proving performance against specific acceptance criteria for a new, innovative device with a primary clinical outcome. Therefore, many of the requested details about acceptance criteria for device performance, especially in a comparative effectiveness study or involving expert ground truth, are not directly applicable or available in this document.

    However, I can extract information related to what constitutes "acceptance" in the context of this 510(k) submission, which is primarily demonstrating substantial equivalence and meeting non-clinical performance and safety standards.

    Here's an interpretation based on the provided text:

    Acceptance Criteria and Reported Device Performance

    For this 510(k) submission, the "acceptance criteria" are implicitly tied to demonstrating substantial equivalence to the predicate devices and meeting relevant safety and performance standards. The reported device performance is that it meets these standards and is comparable to the predicates.

    Acceptance Criteria (Implied for 510(k) Equivalence)Reported Device Performance
    Intended Use Equivalence: The device's intended use is substantially equivalent to predicate devices, potentially with more specificity but without raising new safety/efficacy concerns.The Laser Peripherals Laser Fiber is indicated for use in all surgical specialties in which compatible laser systems with operational wavelengths between 500nm – 2200nm have received regulatory clearance. Laser Peripherals surgical fiber optic laser delivery devices are intended for use with any cleared surgical laser with an SMA 905 connector, SMA 906 connector, or manufacturer specific connectors and adaptors. The intended uses are similar to predicate devices, with clarifying specificity (e.g., removing "Diode" for generic term of Laser Fiber based on light wavelength). This "does not raise any new issues of safety or efficacy."
    Technological Characteristics Equivalence: The device shares the same fundamental scientific technology and characteristics as predicate devices.The device's components (connector configurations, fiber materials like silica core with fluoropolymer hard cladding, acrylate, Teflon, nylon, or polyimide buffer; silica cladding with fluoropolymer coating) and jacket materials (Teflon, Peek) are "similar" to predicates. It utilizes high OH or Low OH silica material with low attenuation of light wavelengths between 500nm - 2200nm (predicate range 532nm - 2100nm, one predicate 500nm - 2200nm), and numerical apertures (NA) between 0.22 – 0.48, which are "similar." Multiple configurations of distal tips are offered, "similar" to predicates. Used with attachments (hand-pieces, endoscopes, cannulas, introducers) is "similar." Core diameters are offered in a range of sizes. Power ranges are 1-300 Watts (one predicate 30W/50W). Compatibility with surgical laser systems via appropriate connection is "similar." The fiber core and cladding are made from silica, the same material as in predicate devices. There are "no differences in technology" that raise new questions on safety or efficacy. Features like Scatter Free Fiber, expanded transmission of laser wavelength/energy, and the LaseGuide Nav distal tip configuration were tested and shown to be safe and effective.
    Safety and Performance Standards Compliance: The device meets recognized consensus standards for medical devices and relevant performance testing.The device complies with numerous ISO and ASTM standards related to sterilization (ISO 11135-1, ISO 10993-7), packaging (ISO 11607-1, ASTM D4169, ASTM F88-09, ASTM F2096-11, ASTM F1980-07), biocompatibility (ISO 10993-1, -5, -10, -11, ASTM F56-13, ASTM F619-14), risk management (ISO 14971), cleanrooms (ISO 14644-1), and reprocessing (AAMI TR12, ISO 17664). Bench testing was conducted for performance, biocompatibility, packaging and shipping, and sterilization. Specific performance tests include: Power & Energy input versus output, homogeneity of output light (spot check, beam profile), high-power testing, bend radius testing, pull testing, and feature-specific testing (e.g., Nav Tip ability to traverse deflected endoscope). These tests collectively demonstrated the device performs as intended with same or similar results as predicate device design and did "not raise new safety or efficacy questions."

    Study Details (as inferred from the 510(k) submission):

    This submission primarily relies on non-clinical performance testing to demonstrate substantial equivalence, rather than a clinical study with diagnostic outcomes.

    1. Sample Size used for the test set and the data provenance:

      • The document does not specify a "test set" in the sense of a clinical or expert-reviewed dataset. The testing was bench testing on physical device samples.
      • The sample sizes for the various non-clinical engineering and bench tests (e.g., power output, bend radius, pull testing, biocompatibility, packaging) are not explicitly stated in this summary. These quantities would be detailed in the full test reports referenced (e.g., Section 18).
      • Provenance: This is entirely laboratory/bench test data, likely conducted internally by Laser Peripherals, LLC, or by accredited labs per standards. It is retrospective in the sense that the test results confirm the design's performance.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • Not applicable. This submission focuses on non-clinical engineering and performance testing, not on diagnostic accuracy requiring expert interpretation or ground truth establishment in a clinical context. The "ground truth" for these tests are objective measurements against defined engineering specifications and standard requirements.
    3. Adjudication method for the test set:

      • Not applicable. There was no expert adjudication process involved, as the "test set" consists of objective measurements from physical bench tests.
    4. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, an MRMC comparative effectiveness study was not done. This device is a bare laser fiber, a surgical instrument, not an AI-assisted diagnostic tool or an imaging device. Therefore, the concept of human readers improving with AI assistance is not relevant to this submission.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • Not applicable. This is a physical medical device (laser fiber), not an algorithm or software. Its performance is inherent in its physical properties and how it delivers laser energy.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • The "ground truth" for this device's evaluation is primarily based on engineering specifications, compliance with recognized consensus standards (ISO, ASTM), and objective physical measurements from bench testing. For biocompatibility, it's defined by the outcomes of standard biological tests. For sterilization, it's meeting validated sterilization parameters.
    7. The sample size for the training set:

      • Not applicable. This is a physical device, not a machine learning model, so there is no "training set" in the AI sense. The design and manufacturing process would involve internal development and verification cycles, but not a dataset for algorithm training.
    8. How the ground truth for the training set was established:

      • Not applicable. As there is no training set, there is no ground truth establishment for one.
    Ask a Question

    Ask a specific question about this device

    K Number
    K120926

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-07-27

    (122 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    Why did this record match?
    Reference Devices :

    K972272, K011207, K050108, K011703

    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EndoBeam™ Holmium Laser Fibers are indicated for a variety of surgical uses including open, laparoscopic or endoscopic ablation, incision, excision, vaporization, and coagulation of soft and cartilaginous tissue and in surgical procedures involving vaporization, ablation and fragmentation of calculi.

    The delivery system may be used in surgical specialty or procedures for which compatible Holmium and Nd:YAG lasers have received regulatory clearance. Refer to the applicable laser system user manual for complete information regarding applications, contraindications, precautions and warnings when using this fiber.

    Device Description

    The EndoBeam™ Holmium Laser Fibers are free-beam delivery devices that transmit laser energy in a forward direction. The devices are either 2.5 meters (8.2 ft.) or 3.0 meters (9.8 ft) in length and are terminated with a laser specific connector on the proximal end. These delivery systems are capable of delivering Ho:YAG (2140nm) and Nd:YAG (1064nm). The devices are either single use or reusable and are supplied Ethylene Oxide (EtO) sterilized.

    The Bard Holmium series of laser fibers are fiber optic laser energy delivery devices consisting of an SMA 905 connector, strain relief, and a silica core/silica clad fiber jacketed with ethylene tetrafluoroethylene (ETFE). The fibers are further equipped with a polished, flat output tip. These fibers may be used in a variety of laser-based surgical cases as an integral part of laser systems.

    The line of reusable laser fibers will feature a protective sheath outside of the jacketed fiber and extending from the strain relief to the midpoint of the fiber length.

    AI/ML Overview

    This document describes the 510(k) premarket notification for the "EndoBeam™ Holmium Laser Fibers" (K120924/K120926). The information provided focuses on demonstrating substantial equivalence to predicate devices, rather than an AI/ML-based device requiring detailed performance metrics against a defined ground truth derived from expert consensus or pathology. Therefore, many of the requested fields are not applicable in this context.

    Here's an analysis based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The submission focuses on demonstrating substantial equivalence by showing that the EndoBeam™ Holmium Laser Fibers have the same technological characteristics and intended use as predicate devices, and that nonclinical performance testing confirms their safety and effectiveness. The acceptance criteria are implicitly met by successful completion of these nonclinical tests and by showing equivalence to legally marketed devices.

    Acceptance Criteria (Implied)Reported Device Performance
    Technological Characteristics EquivalenceThe EndoBeam™ Holmium Laser Fibers have the same technological characteristics as the predicate devices: silica core/cladding, hard-fluoropolymer coating, and ETFE fiber jacket.
    Intended Use EquivalenceThe EndoBeam™ Holmium Laser Fibers have the same intended use as the predicate devices, indicated for a variety of surgical uses including ablation, incision, vaporization, and coagulation of soft/cartilaginous tissue and fragmentation of calculi.
    Nonclinical Functional Performance (Safety & Effectiveness)Nonclinical functional performance testing included visual, functional, and tensile strength testing carried out per internal test methods and IEC 61754-22.
    BiocompatibilityNonclinical biocompatibility testing was conducted in accordance with ISO 10993-1:2009 and FDA Bluebook Memorandum G95-1.
    Substantial Equivalence to Predicate DevicesNonclinical test data demonstrate that the device is safe and effective and is substantially equivalent to the legally marketed predicate devices (Laser Peripherals Holmium Bare Fibers (K972272), Laser Peripherals Reusable Holmium Fiber (K011207), SureFlex™ Laser Fiber (K050108), SlimLineEZ™ Fiber Delivery Device (K011703)).

    Regarding the other requested information:

    This 510(k) submission is for a physical medical device (holmium laser fibers) and does not involve AI or algorithms that would require a test set, ground truth established by experts, or training data in the typical sense of AI/ML performance evaluation. Therefore, the following points are not applicable to this submission.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Not Applicable: This filing does not describe a software or AI/ML device that uses a test set of data for performance evaluation. The "performance data" refers to nonclinical functional and biocompatibility testing of the physical device.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Not Applicable: There is no "ground truth" establishment by experts in the context of an AI/ML system for this type of device submission.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    • Not Applicable: No test set or expert adjudication is described for this device.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • Not Applicable: This is a physical laser fiber, not an AI-assisted diagnostic or treatment system.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • Not Applicable: This is a physical medical device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    • Not Applicable: Ground truth for AI/ML performance is not relevant here. The "ground truth" for this device's safety and effectiveness is established through adherence to recognized standards (e.g., ISO 10993-1:2009, IEC 61754-22) and by demonstrating equivalence to predicate devices that have prior regulatory clearance and established safety records.

    8. The sample size for the training set

    • Not Applicable: No training set is involved.

    9. How the ground truth for the training set was established

    • Not Applicable: No training set with ground truth is involved.
    Ask a Question

    Ask a specific question about this device

    K Number
    K050738

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2005-06-02

    (77 days)

    Product Code
    Regulation Number
    878.4810
    Age Range
    All
    Why did this record match?
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Laser peripherals bare laser fibers, ENT fibers and Endoprobes are intended for use in laser surgical procedure for cutting, coagulating, or vaporizing in any soft tissue application for which compatible Nd: YAG, Ho: YAG, KTP and Diode lasers have been cleared.

    Device Description

    Fiber Optic Delivery Systems and Handpieces are intended to vaporize, coagulate, incise and excise tissue and which are designed for any indication for which compatible laser systems have been cleared by FDA. Similarly, the predicate devices are also components of delivery systems designed to deliver laser radiation to a specified point. FiberTech's Fiber Optic Delivery System's fiber optical Handpiece and Tip has a similar material composition as its predicate devices. Third, the Fiber Optic Delivery System is available in sizes between 200 micron and 1000 micron. Ceramoptec's and Coherent Laser Delivery Systems is available also in sizes ranging from 200 micron to 1000 micron. Fourth, the reusable and the disposable Fiber Optic Delivery Systems are available in the same tip shapes and handpiece configurations. Further, both the reusable and the disposable devices are prepackaged sterile and fit lasers which employ SMA 905 connectors or lasers which have suitable adapters to allow SMA 905 connectors to be used. Finally, the reusable Fiber Optic Delivery System can be reused only once the optical fiber tip is properly cleaned, inspected, stripped and cleaved.

    AI/ML Overview

    The provided text is a 510(k) summary for the FiberTech's USA Fiber Optic Delivery System. It describes the device, its intended use, and its substantial equivalence to predicate devices. However, it does not contain information about acceptance criteria or a study proving the device meets those criteria in the way typically associated with AI/ML-based device performance evaluations (e.g., accuracy, sensitivity, specificity studies).

    Instead, this document focuses on demonstrating substantial equivalence to existing legally marketed predicate devices, which is the standard for 510(k) clearances. The "Performance Data" section primarily refers to certifications, not clinical performance metrics.

    Therefore, I cannot fulfill your request for the specific points about acceptance criteria and study details because the provided document does not contain that type of information. It's a regulatory document for a physical medical device, not an AI/ML software as a medical device.

    Here's a breakdown of why the requested information is absent:

    1. A table of acceptance criteria and the reported device performance: Not provided. The document states "no new questions of safety and effectiveness raised by the introduction of this devices" based on similarity to predicates, rather than quantifiable performance metrics against specific acceptance criteria.
    2. Sample sized used for the test set and the data provenance: Not applicable. Performance is established through comparison to predicate devices and existing certifications, not through a separate clinical test set in the traditional sense for an AI/ML device.
    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable.
    4. Adjudication method for the test set: Not applicable.
    5. If a multi reader multi case (MRMC) comparative effectiveness study was done: Not applicable. This is not an AI-assisted device.
    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc): Not applicable.
    8. The sample size for the training set: Not applicable.
    9. How the ground truth for the training set was established: Not applicable.

    The "Performance Data" section (Section 2) mentions:

    • CE marking (Medical Device Directive 95.E.02)
    • Certification under EN ISO 19407:2009
    • Certification for Quality EN ISO 9001:2000

    These are quality management system and regulatory compliance certifications, not direct performance metrics of the device itself (like accuracy of an AI algorithm). The basis for clearance is substantial equivalence to the predicate devices listed (Ceramoptec's Fiber Optic Delivery Sytems, InnovaQuartz Fiber Optic Delivery System, Laser Peripherals Fiber Optic Delivery System, Trymedyne Inc., Fiber Optic Delivery System). The argument for substantial equivalence is based on:

    • Intended Use
    • Technological Characteristics (material composition, available sizes, tip shapes, handpiece configurations, sterile packaging, connector types, reusability)

    In summary, this document is a 510(k) submission for a physical medical device. It relies on demonstrating similarity to already cleared devices and adherence to manufacturing and quality standards, rather than presenting a performance study with acceptance criteria and ground truth, as would be expected for an AI/ML-based medical device.