510(k) Data Aggregation
(110 days)
The iFuse INTRA Ti Implant System is intended for fusion of the sacroiliac joint for sacroiliac joint dysfunction that is a direct result of sacroiliac joint disruption and degenerative sacroiliitis. This includes conditions whose symptoms began during pregnancy or in the peripartum period and have persisted postpartum for more than 6 months.
The iFuse INTRA Ti Implant System consists of a sterile, single-use implant with porous features designed to promote joint fusion. The implant is additively manufactured using Ti-6Al-4V ELI per ASTM F3001. The iFuse INTRA Ti instruments are single-use devices used for placement of the implant.
N/A
Ask a specific question about this device
(72 days)
The Falco Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.
The Falco Fusion System is designed to stabilize or fuse the sacroiliac (SI) joint, helping to reduce pain and improve mobility in patients suffering from SI joint disruptions or degenerative sacroiliitis. The system includes titanium alloy screws (Ti-6Al-4V ELI, ASTM F-136) in diameters of 11mm and 13mm, with lengths ranging from 35mm to 75mm. Additionally, the system comes with disposable Kirschner wires (316-LVM, ASTM F138) and reusable surgical (Stainless Steel, ASTM F899) instruments, providing a comprehensive solution for sacroiliac joint fusion procedures.
N/A
Ask a specific question about this device
(145 days)
The Sacroiliac Joint Truss System is indicated for sacroiliac joint fusion for:
- Sacroiliac joint dysfunction including sacroiliac joint disruption and degenerative sacroiliitis.
- Augmenting immobilization and stabilization of the sacroiliac joint in skeletally mature patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion.
The Sacroiliac Joint Truss System is also indicated for fracture fixation of the pelvis, including acute, non-acute and nontraumatic fractures.
The SJTS is a comprehensive surgical solution for sacroiliac joint fusion procedures. The system consists of an instrument set and a wide range of threaded implants. All screws in the 4Web SJTS are cannulated, fenestrated, and made of medical grade Ti6Al4V alloy. The screws come in two distinct sterile implant offerings: a fully threaded screw with compression threads on the proximal head and a partially threaded lag screw with an accompanying washer. The implant offering includes a choice of three different diameters with a variety of lengths to accommodate the patient's anatomy.
The SJTS is intended for use with autograft and/or allogenic bone graft comprised of cancellous and/or corticocancellous bone graft.
N/A
Ask a specific question about this device
(203 days)
The OptumSI Implant System is intended for sacroiliac fusion for the following conditions:
- Sacroiliac joint dysfunction that is a direct result of sacroiliac joint disruption and degenerative sacroiliitis. This includes conditions whose symptoms began during pregnancy or in the peripartum period and have persisted postpartum for more than 6 months.
- To augment immobilization and stabilization of the sacroiliac joint in skeletally mature patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion.
- Acute, non-acute, and non-traumatic fractures involving the sacroiliac joint.
The OptumSI Implant System consists of a cannulated diamond-shape, titanium implant (Ti-6Al-4V ELI, ASTM 3001) with a porous surface. The implant is available in varying lengths and are provided sterile and individually packaged. The system utilizes a transverse approach with a lateral or lateral-to-medial trajectory from the ilium to the sacrum. Instruments are provided as a reprocessable set to assist with gaining access and delivering the implant as intended. The principle operation is based on the diamond-shape and porous surface which are designed to prevent and minimize motion of the sacroiliac (SI) joint, thereby stabilizing the joint or fracture. The mechanism of action is that the interference fit allows for fixation, stabilization, and fusion.
N/A
Ask a specific question about this device
(89 days)
The SIros-X System is intended for sacroiliac joint fusion in skeletally mature patients for the following conditions:
• Sacroiliac joint dysfunction that is a direct result of sacroiliac joint disruption and degenerative sacroiliitis. This includes conditions whose symptoms began during pregnancy or in the peripartum period and have persisted postpartum for more than 6 months.
• To augment immobilization and stabilization of the sacroiliac joint in patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion.
• Acute, non-acute, and non-traumatic fractures involving the sacroiliac joint.
When connected to the TiLock2 Spinal System, the SIros-X System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to thoracolumbosacral fusion for the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine:
• Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies
• Spondylolisthesis
• Trauma (i.e., fracture or dislocation)
• Spinal stenosis
• Deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis)
• Spinal tumor
• Pseudarthrosis
• Failed previous fusion
When connected to the TiLock2 Spinal System, the SIros-X System is intended to provide immobilization and stabilization of spinal segments in skeletally immature patients as an adjunct to thoracolumbar fusion for the treatment of progressive spinal deformities (i.e., scoliosis, kyphosis, or lordosis) including idiopathic scoliosis, neuromuscular scoliosis, and congenital scoliosis, as well as the following conditions: spondylolisthesis/spondylolysis, fracture caused by tumor and/or trauma, pseudarthrosis, and/or failed previous fusion. These devices are to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach.
The SIros-X Navigation instruments are intended to be used with the SIros-X System to assist the surgeon in precisely locating anatomical structures in SIros-X System procedures, in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the pelvis or vertebra, can be identified relative to the acquired image (CT, MR, 2D fluoroscopic image or 3D fluoroscopic image reconstruction) and/or an image data-based model of the anatomy. The SIros-X Navigation instruments are intended to be used with the Medtronic StealthStation System.
The SIros-X System is comprised of cannulated screws of various lengths, diameters, and configurations as well as system specific instruments. Instruments are offered to support open and minimally invasive placement of the SIros-X screws.
The SIros-X System is intended to provide fusion of the sacroiliac joint when multiple SIros-X screws traverse the SI joint. In addition, screws with tulips are intended to provide fixation to the pelvis when used with multi-level pedicle screw constructs that terminate in the lumbosacral spine.
The SIros-X System navigation instruments are offered to assist the surgeon in precisely locating anatomical structures in SIros-X System procedures in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the pelvis or vertebra, can be identified relative to the acquired image (CT, MR, 2D fluoroscopic image or 3D fluoroscopic image reconstruction) and/or an image data-based model of the anatomy.
N/A
Ask a specific question about this device
(16 days)
The iFuse Bedrock Granite Implant System is intended for sacroiliac joint fusion in skeletally mature patients for the following conditions:
• Sacroiliac joint dysfunction that is a direct result of sacroiliac joint disruption and degenerative sacroiliitis. This includes conditions whose symptoms began during pregnancy or in the peripartum period and have persisted postpartum for more than 6 months.
• To augment immobilization and stabilization of the sacroiliac joint in patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion.
• Acute, non-acute, and non-traumatic fractures involving the sacroiliac joint
When connected to compatible pedicle screw systems with 5.5- or 6.0-mm posterior rods made from either titanium alloy or cobalt chrome alloys, the iFuse Bedrock Granite Implant System is intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to thoracolumbosacral fusion for the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine:
• Degenerative disc disease (DDD) as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies
• Spondylolisthesis
• Trauma (i.e., fracture or dislocation)
• Spinal stenosis
• Deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis)
• Spinal tumor
• Pseudarthrosis
• Failed previous fusion
When connected to compatible pedicle screw systems with 5.5- or 6.0-mm posterior rods made from either titanium alloy or cobalt chrome alloys, the iFuse Bedrock Granite Implant System is intended to provide immobilization and stabilization of spinal segments in skeletally immature patients as an adjunct to thoracolumbar fusion for the treatment of progressive spinal deformities (i.e., scoliosis, kyphosis, or lordosis) including idiopathic scoliosis, neuromuscular scoliosis, and congenital scoliosis, as well as the following conditions: spondylolisthesis/spondylolysis, fracture caused by tumor and/or trauma, pseudarthrosis, and/or failed previous fusion. These devices are to be used with autograft and/or allograft. Pediatric pedicle screw fixation is limited to a posterior approach.
Please refer to the additional information section in the Instructions for Use on compatible pedicle screw system rods.
The iFuse Bedrock Granite Navigation instruments are intended to be used with the iFuse Bedrock Granite Implant System and the Medtronic StealthStation System to assist the surgeon in precisely locating anatomical structures in iFuse Bedrock Granite Implant System procedures, in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure, such as the pelvis or vertebra, can be identified relative to the acquired image (CT, MR, 2D fluoroscopic image or 3D fluoroscopic image reconstruction) and/or an image data-based model of the anatomy.
The Granite iGPS instruments and iGPS Drill Bits are compatible with Globus ExcelsiusGPS® Instrument Trackers and intended to be used with the iFuse Bedrock Granite Implant System and the Globus ExcelsiusGPS® Robotic Navigation System (including the Globus Excelsius3D® Imaging System), which is intended for use as an aid for precisely locating anatomical structures and for spatial positioning and orientation of an instrument holder or guide tube to be used by surgeons for navigating and/or guiding compatible surgical instruments in open or percutaneous procedures provided that the required fiducial markers and rigid patient anatomy can be identified on CT scans or fluoroscopy.
Use of the iGPS instruments is limited to use only with the 9.5 mm and 10.5 mm iFuse Bedrock Granite implants.
The iFuse Bedrock Granite® Implant System consists of implants of various lengths and diameters, and associated instruments sets. Instrument sets are provided for both open and minimally invasive approaches. The titanium (Ti-6Al-4V ELI) implant consists of a porous fusion sleeve with threaded length attached to a solid post that has connection and implant placement features of a typical pedicle fixation screw. It is intended to provide sacroiliac joint fusion in the sacral alar iliac (SAI) trajectory (when used with commercially available sacroiliac joint fusion promoting devices), and foundational stabilization when connected to pedicle screw fixation systems in both the SAI and the iliac trajectories. Additionally, iFuse Bedrock Granite can be placed into the S1 pedicle. The device is designed for connection to commercially available pedicle screw systems via Ø5.5 mm or Ø6.0 mm titanium alloy or cobalt chrome alloy spinal fixation rods.
The purpose of this submission is to add an alternative option for the set screw (referred to as the Granite Point Lock Set Screw) used with the iFuse Granite Implant System.
N/A
Ask a specific question about this device
(196 days)
The Eminent Spine Posterior SI System is intended for sacroiliac joint fusion for conditions including degenerative sacroiliitis and sacroiliac joint disruptions, to augment immobilization and stabilization of the sacroiliac joint in skeletally mature patients undergoing sacropelvic fixation as part of a lumbar or thoracolumbar fusion. This includes those whose symptoms began during pregnancy or in the peripartum period and have persisted postpartum for more than 6 months.
The Eminent Spine Posterior SI System is inserted through an SI posterior approach and packed with autogenous bone graft to facilitate fusion. There are teeth on the superior and inferior surfaces of the device to inhibit movement of the device and to aid in expulsion resistance, while screws are inserted through the anterior face of the implant for bone fixation, adding compression and transfixation in the SI joint. The device is intended to provide mechanical support to the implanted level until fusion is achieved.
The cages are made from additively manufactured Ti-6Al-4V per ASTM F3001. The integrated fixation screws and screw anti-backout plate are manufactured from Ti-6Al-4V ELI per ASTM F136.
The SI posterior system cages are available in one footprint with a lordotic angle. The anterior face of the cage has one screw anti-backout plate that rotates to cover the screw heads and prevent the screws from backing out of the cage after insertion. The screws are available in two diameters (Ø3.50mm, Ø3.75mm), in lengths ranging from 10-18 mm. The screws are positioned to span and compress the cortices of the ilium and sacrum of the SI joint.
N/A
Ask a specific question about this device
(147 days)
The SImmetry+ System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.
The SImmetry+ System consists of sterile packaged fully threaded titanium Implants designed to transfix the sacrum and ilium, providing stability for bony fusion. The surgical implants are available in various sizes to accommodate patient anatomy. Implants have major diameters ranging from 9.5mm-14.5mm, in 1mm increments. Implant lengths in 5mm increments range from 30mm to 110mm. All devices are additively manufactured from Titanium Alloy (Ti-6Al4V ELI).
This 510(k) clearance letter pertains to the SImmetry+ System, a device for sacroiliac joint fusion (a metallic bone fixation fastener). Unlike a clearance for a software device or AI/ML system, this document focuses on the physical and mechanical performance of the implantable device.
Therefore, the requested information regarding acceptance criteria and study that proves the device meets the acceptance criteria specifically in the context of AI/ML performance metrics (like sensitivity, specificity, MRMC studies, expert consensus on images, etc.) is not applicable to this type of medical device clearance.
The provided document describes:
- Device Type: A physical, implantable device (fully threaded titanium implants for sacroiliac joint fusion).
- Acceptance Criteria (Implicitly): Demonstrated through non-clinical performance testing against specific ASTM standards. These standards define the expected mechanical properties (e.g., static and dynamic cantilever testing, axial pullout, torsional properties, driving torque).
- Study Proving Acceptance: "Non-clinical testing data" was submitted, including:
- Static and dynamic cantilever testing per ASTM F2193
- Axial pullout testing per ASTM F543
- Torsional properties testing per ASTM F543
- Driving torque testing per ASTM F543
- Additive manufacturing characterization
Summary of Requested Information based on the provided document:
-
A table of acceptance criteria and the reported device performance:
- Acceptance Criteria: Mechanical performance standards defined by ASTM F2193 and ASTM F543, and additive manufacturing characterization. (Specific numerical thresholds are not provided in this public clearance letter, but would have been part of the confidential submission.)
- Reported Device Performance: The document states that SiVantage completed non-clinical testing and the data demonstrates substantial equivalence. This implies the device met the performance criteria outlined in the standards.
-
Sample sizes used for the test set and the data provenance: Not applicable. The "test set" here refers to physical implants subjected to mechanical testing, not a dataset of patient information for AI/ML evaluation.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts: Not applicable. Ground truth for a physical implant is established by engineering measurements against defined material and mechanical standards.
-
Adjudication method for the test set: Not applicable. Mechanical testing results are objective measurements.
-
If a multi-reader multi-case (MRMC) comparative effectiveness study was done: Not applicable. This type of study is for evaluating human interpretation of medical images, often with AI assistance.
-
If a standalone (i.e., algorithm only without human-in-the-loop performance) was done: Not applicable. This is for AI/ML algorithm performance.
-
The type of ground truth used:
- For the physical device: Engineering specifications, material properties, and mechanical performance standards (ASTM F2193, ASTM F543).
-
The sample size for the training set: Not applicable. The "training set" concept applies to AI/ML model development. For a physical device, manufacturing processes are refined, but there isn't a "training set" in the AI sense.
-
How the ground truth for the training set was established: Not applicable for a physical device.
In conclusion, this FDA 510(k) clearance is for a conventional mechanical implant, not an AI/ML powered device. Therefore, many of the questions asked, which are highly relevant for AI/ML device clearances, do not apply to the details provided in this document. The "proof" of meeting acceptance criteria for this device rests on its physical and mechanical characteristics meeting established engineering standards and showing substantial equivalence to existing predicate devices based on those characteristics.
Ask a specific question about this device
(163 days)
The panaSIa SI Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.
The panaSIa SI Fusion device is a threaded, expandable device, designed to stabilize the sacroiliac joint by piercing the adjacent cortical bone when expanded. The device has large fenestrations to allow for uninterrupted graft contact across the SI joint space. The panaSIa SI Fusion implant is a sterile, single patient use, long-term implantable device made of a titanium grade alloy.
The provided FDA 510(k) clearance letter for the "panaSIa SI Fusion System" describes a medical device, specifically a smooth or threaded metallic bone fixation fastener, intended for sacroiliac (SI) joint fusion.
Based on the provided document, the acceptance criteria and the study proving the device meets these criteria are limited in detail. This is typical for a 510(k) clearance for this type of device, which primarily focuses on demonstrating substantial equivalence to a predicate device through non-clinical performance testing rather than extensive clinical studies or AI algorithm performance validation.
Here's an analysis of the provided information, addressing your points where possible, and noting where information is not present in the document.
Overview of Device and Clearance Type
The panaSIa SI Fusion System is a physical implant (a threaded, expandable device made of titanium grade alloy) used for sacroiliac joint fusion. The FDA clearance is a 510(k), which means the manufacturer demonstrated the device is substantially equivalent to legally marketed predicate devices. This type of clearance typically relies on non-clinical testing (e.g., mechanical performance) and comparison of design, materials, and indications for use, rather than extensive human clinical trials or complex AI performance metrics.
Acceptance Criteria and Study Details (Based on Provided Document)
1. Table of Acceptance Criteria and Reported Device Performance
For this type of device and submission (510(k) for a physical implant), the "acceptance criteria" are not explicitly quantifiable metrics like sensitivity/specificity for an AI algorithm. Instead, they are typically the successful fulfillment of recognized standards and comparative performance to predicates.
| Acceptance Criteria Category | Specific Acceptance Criteria (Inferred from Document) | Reported Device Performance (From Document) |
|---|---|---|
| Intended Use Equivalence | Same intended use as predicate devices. | "The panaSIa SI Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis." - Matches indications for predicate devices. |
| Principles of Operation Equivalence | Similar principles of operation as predicate devices. | "The subject device and the predicate devices have similar principles of operation..." |
| Design Equivalence | Similar design as predicate devices. | "...designs..." |
| Material Equivalence | Similar materials as predicate devices. | "...and use similar materials. The panaSIa SI Fusion implant is a sterile, single patient use, long-term implantable device made of a titanium grade alloy." |
| Performance (Mechanical) Equivalence | Meets or exceeds mechanical testing standards (ASTM F3574) and performs comparably to predicate in relevant tests (e.g., cadaver testing). | "The non-clinical testing data submitted and relied upon to demonstrate substantial equivalence included static and dynamic vertical shear testing per ASTM F3574 and cadaver testing with comparison to the additional predicate device." |
| Safety & Effectiveness | Demonstrates comparable safety and effectiveness to predicate devices. | "The panaSIa SI Fusion System is as safe, as effective, and performs as well as, or better, than the predicate devices." |
2. Sample Size Used for the Test Set and Data Provenance
- Sample Size: The document mentions "cadaver testing," which refers to ex vivo testing of the device. However, it does not specify the sample size (i.e., number of cadavers or test specimens from cadavers) used for this testing.
- Data Provenance: The document does not specify the country of origin of the cadaver data or whether the testing was retrospective or prospective. Given it's cadaver testing, it's inherently a controlled, ex vivo experimental setup rather than a patient-based retrospective/prospective study.
3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications of Experts
- This information is not applicable/not provided in this type of 510(k) submission. The "ground truth" for a physical implant's mechanical performance is typically established by engineering standards (like ASTM F3574) and direct measurement, not by expert consensus on image interpretation or clinical outcomes.
4. Adjudication Method for the Test Set
- Adjudication methods (e.g., 2+1, 3+1) are typically used for establishing ground truth in clinical imaging studies or clinical trials where human interpretation or consensus is required. This information is not applicable/not provided for a mechanical device performance test.
5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study
- This type of study is relevant for AI-powered diagnostic devices where the AI assists human readers (e.g., radiologists interpreting images). This device is a physical implant; therefore, no MRMC study was done or is relevant for this submission.
6. Standalone (Algorithm Only) Performance Study
- This refers to the performance of an AI algorithm alone, without human intervention. Since this is a physical medical device and not an AI algorithm, a standalone algorithm performance study was not conducted or is not relevant.
7. Type of Ground Truth Used
- For the non-clinical performance testing:
- Mechanical Standards: Adherence to established engineering standards (ASTM F3574 for static and dynamic vertical shear testing).
- Comparative Performance: The performance of the device was directly compared against a predicate device in cadaver models. While not explicitly stated as "ground truth," the predicate device's known performance serves as the benchmark against which the new device is measured.
- No clinical outcomes or pathology ground truth was used for this 510(k) clearance, as it is based on substantial equivalence through non-clinical testing.
8. Sample Size for the Training Set
- This device is not an AI algorithm, so there is no "training set" in the context of machine learning. The design and manufacturing processes are likely informed by engineering principles, material science, and prior device designs, but not through a formalized data training set as seen in AI development.
9. How the Ground Truth for the Training Set Was Established
- As there is no AI "training set," this question is not applicable.
In summary, the provided FDA 510(k) clearance letter details a non-AI medical device (an SI joint fusion implant). The "acceptance criteria" and "study" proving these criteria are primarily based on:
- Substantial equivalence to legally marketed predicate devices in terms of intended use, principles of operation, design, and materials.
- Non-clinical performance testing, specifically:
- Adherence to ASTM F3574 for static and dynamic vertical shear testing.
- Comparative cadaver testing against an additional predicate device.
The document does not delve into the detailed quantitative results of these tests (e.g., exact maximum shear force sustained), sample sizes of cadavers, or the specific methods of ground truth establishment beyond relying on industry standards and direct comparison. This level of detail for non-clinical testing is typically found within the full 510(k) submission, not the public-facing clearance letter.
Ask a specific question about this device
(52 days)
The Rialto™ SI Fusion System is intended for sacroiliac joint fusion for conditions including sacroiliac joint disruptions and degenerative sacroiliitis.
The subject RIALTO™ SI Fusion System consists of cannulated devices available in various lengths, used to provide stabilization when fusion of the sacroiliac joint is desired. Autograft and/or allograft may be placed in conjunction with the RIALTO™ SI Fusion System. The RIALTO Screws are made using Titanium Alloy and are 40mm- 60mm in length with a diameter of 12mm. This device may be implanted via a minimally invasive approach using fluoroscopy or navigated instruments compatible with Medtronic StealthStation® and IPC® POWEREASE®.
The provided FDA 510(k) clearance letter for the Rialto™ SI Fusion System does not contain information about the acceptance criteria and study proving a device meets those criteria in the context of an AI/Software as a Medical Device (SaMD).
The document describes a medical implant (Rialto™ SI Fusion System) and its mechanical and MRI safety performance, not an AI or software device. The studies mentioned (ASTM F2182-19e2, F2052-21, F2213-17, F2119-24, F2503-23) are for evaluating the safety and compatibility of passive implants in the Magnetic Resonance (MR) Environment, which are standard non-clinical tests for physical medical devices.
Therefore, I cannot provide the requested information for acceptance criteria and study details related to an AI/SaMD, as the provided input does not pertain to such a device.
If you have a document describing the clearance of an AI/SaMD, I would be happy to analyze it for the requested information.