Search Filters

Search Results

Found 206 results

510(k) Data Aggregation

    K Number
    K251793

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2026-03-03

    (265 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K252570

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-11-10

    (88 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    EzSensor HD / UHD is intended to collect dental x-ray photons and convert them into electronic impulses that may be stored, viewed and manipulated for diagnostic use by dentists.

    Device Description

    EzSensor HD / UHD is a digital intraoral sensor which acquires intra oral images with a sensor that is connected to a computer to produce an image almost instantaneously following exposure. The primary advantage of Indirect sensor systems is the speed with which images are acquired. The ergonomic design based on human intraoral anatomy improves patient comfort. EzSensor HD / UHD includes the software (firmware) with basic level of concern.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250687

    Validate with FDA (Live)

    Date Cleared
    2025-10-24

    (232 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Cocoon Solo (DX-7020s) is a portable x-ray system indicated for taking diagnostic dental x-rays for both pediatric and adult patients.

    Device Description

    Cocoon Solo (DX-7020s) is a handheld, portable X-ray device designed for dental radiographic examination and diagnosis for pediatric and adult patients by exposing a X-ray image receptor to ionizing radiation.

    The X-ray tube is located inside the device body to be used with conventional film (F-speed or greater film), PSP (Phosphor plates), or digital X-ray sensors.

    The image detectors (an integral part of a fully-functional diagnostic x-ray system) are not part of the submission.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251206

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-09-24

    (159 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Digital X-Ray DentiMax Pro Imaging System is intended to be used with standard digital X-ray systems to collect dental x-rays photons and convert them into dental images that may be stored, viewed, and manipulated by dentists for the diagnosis of disease of the teeth, jaw, and oral structures.

    Device Description

    The Digital X-Ray DentiMax Pro Imaging System consists of intraoral digital sensors and the optional DentiMax Imaging Software application. This system provides image acquisition, storage, and display functions for dental radiography. The digital intraoral x-ray sensors are based on complementary metal-oxide semiconductor (CMOS) technology. A scintillating material converts the incident x-rays into visible light, the light is coupled optically to a CMOS technology light detection imager and then is converted to digital data. A high-speed direct USB interface enables a simple connection to a computer without need for an additional control box. The design of the sensor assembly supports the automatic detection of incident x-rays to generate digital images for intraoral applications, once armed via a software command. The DentiMax Imaging Software application functions as a viewing software for image acquisition, enhancement, and display; however, it is not required for use of the sensors. The sensors are also compatible with other FDA-cleared dental imaging software commonly available in the marketplace. The optional DentiMax positioner kit helps ensure the system is aligned correctly to capture accurate dental images. The major function of the Digital X-Ray DentiMax Pro Imaging System is to convert X-rays into high-resolution digital images suitable for dental diagnostic use.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K240040

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-10-25

    (294 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The unit is intended to produce panoramic or cephalometric digital x-ray images. It provides diagnostic details of the dento-maxillofacial, sinus and TMJ for adult and pediatric patients. The system also utilizes carpal images for orthodontic treatment. The device is to be operated by physicians, dentists, and x-ray technicians.

    Device Description

    The device is an advanced 2-in-1 digital X-ray imaging system that incorporates PANO and CEPH (Optional) imaging capabilities into a single system and acquires 2D diagnostic image data in conventional panoramic and cephalometric modes.
    The device is not intended for CBCT imaging.
    VistaPano S is identified as panoramic-only models for VistaPano S Ceph.
    ProVecta S-Pan Ceph and ProVecta S-Pan are alternative model for VistaPano S Ceph and VistaPano S respectively.
    The subject device has different model names designated for different US distributors:

    • -VistaPano S Ceph, VistaPano S: DÜRR DENTAL
    • ProVecta S-Pan Ceph, ProVecta S-Pan: AIR TECHNIQUES ।
      Key components of the device
      1. VistaPano S Ceph 2.0 (Model: VistaPano S Ceph), VistaPano S 2.0 (Model: VistaPano S) digital x-ray equipment (Alternate: ProVecta S-Pan Ceph 2.0 (Model: ProVecta S-Pan Ceph), ProVecta S-Pan 2.0 (Model: ProVecta S-Pan))
      1. SSXI detector: Xmaru1501CF-PLUS, Xmaru2602CF
      1. X-ray generator
      1. PC system
      1. Imaging software
    AI/ML Overview

    The provided text describes the substantial equivalence of the new VATECH X-ray imaging systems (VistaPano S Ceph 2.0, VistaPano S 2.0, ProVecta S-Pan Ceph 2.0, ProVecta S-Pan 2.0) to their predicate device (PaX-i Plus/PaX-i Insight, K170731).

    Here's an analysis of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    Acceptance Criteria and Reported Device Performance

    The acceptance criteria are not explicitly stated as numerical metrics in a table. Instead, the document focuses on demonstrating substantial equivalence to a predicate device. This is a common approach for medical device clearance, where the new device is shown to be as safe and effective as a legally marketed device. The "performance" in this context refers to demonstrating that the new device functions similarly or better than the predicate, especially for the new "non-binning" mode.

    The study aims to show that the new device's performance is equivalent or better than the predicate device, particularly for the new "HD mode (non-binning)" in CEPH imaging. The primary comparison points are:

    Acceptance Criteria (Implied by Substantial Equivalence Goal)Reported Device Performance (vs. Predicate)
    PANO Mode Image Quality: Equivalent to predicate."similar" (implied "equivalent")
    CEPH Mode Image Quality (SD/2x2 binning): Equivalent to predicate."same" (as predicate's Fast mode)
    CEPH Mode Image Quality (HD/non-binning): Equivalent or better than predicate."better performance" and "performed better or equivalent in line pair resolution than the predicate device."
    Dosimetric Performance (DAP): Similar to predicate."DAP measurement in the PANO mode of each device under the same X-ray exposure conditions... was similar." and "SD mode... same X-ray exposure conditions (exposure time, tube voltage, tube current) are the same with the Fast mode of the predicate device."
    Biocompatibility of Components: Meets ISO 10993-1 standard."biocompatibility testing results showed that the device's accessory part are biocompatible and safe for its intended use."
    Software Functionality and Safety: Meets FDA guidance for "moderate" level of concern."Software verification and validation were conducted and documented... The software for this device was considered as a 'moderate' level of concern." Cybersecurity guidance was also applied.
    Electrical, Mechanical, Environmental Safety & EMC: Conforms to relevant IEC standards."Electrical, mechanical, environmental safety and performance testing according to standard IEC 60601-1... IEC 60601-1-3... IEC 60601-2-63... EMC testing were conducted in accordance with standard IEC 60601-1-2... All test results were satisfactory."
    Conformity to EPRC standards:"The manufacturing facility is in conformance with the relevant EPRC standards... and the records are available for review."
    DICOM Conformity:"The device conforms to the provisions of NEMA PS 3.1-3.18, Digital Imaging and Communications in Medicine (DICOM) Set."

    Study Details:

    The provided document is a 510(k) summary, not a detailed study report. Therefore, some specific details about the study methodology (like expert qualifications or full sample sizes for clinical images) are not granularly described. However, we can infer some information:

    1. Sample sizes used for the test set and the data provenance:

      • The document states "Clinical images obtained from the subject and predicate devices are evaluated and compared." However, the exact sample size for this clinical image evaluation (the "test set" in AI/ML terms) is not specified.
      • The data provenance is implied to be from a retrospective collection of images, likely from VATECH's own testing/development or existing clinical sites that used the predicate device and potentially early versions of the subject device. The country of origin for the clinical images is not explicitly stated, but given the manufacturer is based in Korea ("VATECH Co., Ltd. Address: 13, Samsung 1-ro 2-gil, Hwaseong-si, Gyeonggi-do, 18449, Korea"), it's reasonable to infer some data might originate from there.
      • For the bench testing, the sample size is also not specified, but it would involve phantoms.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • The document mentions "Clinical images obtained from the subject and predicate devices are evaluated and compared." However, it does not specify the number of experts, their qualifications, or how they established "ground truth" for these clinical images. The evaluation is described in general terms, implying a qualitative assessment of general image quality ("general image quality of the subject device is equivalent or better than the predicate device").
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • The document does not describe any formal adjudication method for the clinical image evaluation. It simply states "evaluated and compared."
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • No, an MRMC study was NOT done. This device is an X-ray imaging system, not an AI-assisted diagnostic tool for interpretation. The study focused on demonstrating the image quality of the system itself (hardware and associated basic image processing software) as being substantially equivalent or better than a predicate system, not on improving human reader performance with AI assistance. The "VisionX 3.0" software is an image viewing program, not an AI interpretation tool.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • This is not applicable in the sense of a diagnostic AI algorithm. The performance evaluation is inherently about the "algorithm" and physics of the X-ray system itself (detector, X-ray generator, image processing pipeline) without human interaction for image generation, but humans are integral for image interpretation. The device's performance (image quality, resolution, DAP) is measured directly, similar to a standalone evaluation of a sensor's capabilities.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • For the bench testing, the ground truth was based on physical phantom measurements (e.g., line pair resolution, contrast using phantoms).
      • For the clinical image evaluation, the "ground truth" or reference was implicitly the subjective assessment of "general image quality" by unspecified evaluators, compared to images from the predicate device. There is no mention of an objective clinical ground truth like pathology or patient outcomes.
    7. The sample size for the training set:

      • The document describes an X-ray imaging system, not a device incorporating a machine learning model that requires a "training set" in the conventional sense. Therefore, there is no mention of a training set sample size. The software mentioned (VisionX 3.0) is a general image viewing program, not a deep learning model requiring a specific training dataset.
    8. How the ground truth for the training set was established:

      • Not applicable, as no external "training set" for a machine learning model is described.
    Ask a Question

    Ask a specific question about this device

    K Number
    K242778

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-10-11

    (28 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    X Sensor is intended to collect dental x-ray photons and convert them into electronic impulses that may be stored, viewed and manipulated for diagnostic use by dentists.

    Device Description

    X Sensor is a digital intraoral sensor which acquires digital intra-oral images. X Sensor acquires intra oral images with a sensor that is connected to a computer to produce an image almost instantaneously following exposure. The primary advantage of direct sensor systems is the speed with which images are acquired. X Sensor includes the firmware for the sensor and the previously cleared imaging software "ExDent-I".

    AI/ML Overview

    The provided text is a 510(k) summary for the X Sensor, a digital dental intraoral sensor. It describes the device's technical characteristics, intended use, and its comparison to a predicate device (EzSensor XHD). However, this document does not contain the detailed information necessary to fully answer your request regarding acceptance criteria and the study proving the device meets these criteria in the context of AI/ML performance.

    Specifically, the document focuses on regulatory clearance for a medical device (an X-ray sensor) based on hardware and image quality performance relative to a predicate device, as well as electrical, mechanical, and software safety. It does not mention any AI/ML components or studies evaluating AI/ML performance.

    Therefore, many parts of your request, such as those related to AI/ML specific acceptance criteria, sample sizes for AI/ML test and training sets, expert adjudication, MRMC studies, or standalone algorithm performance, cannot be answered from the provided text.

    However, I can extract information related to the device's general performance testing and comparison to the predicate device, which serves as a form of "acceptance" for medical device clearance.

    Here's what can be extracted and how it relates to your request, with a clear indication of what information is not present:


    Acceptance Criteria and Device Performance (General Device Performance)

    Based on the document, the "acceptance criteria" appear to be meeting or exceeding the performance of the predicate device (EzSensor XHD) in key technical metrics and demonstrating adequate image quality for diagnostic use.

    Acceptance Criterion (Implicit)Reported Device Performance (X Sensor)
    Image Quality (General)"The performance test result indicates that the X Sensor intra oral sensor performed equally to the EzSensor XHD, the predicated device, as both sensors have the same pixel pitch, thereby providing the same maximum line-pair resolution.""The clinical images obtained from the X Sensor and EzSensor XHD were reviewed and rated comparatively.""The image quality in terms of contrast and resolution are overall similar for the X sensor, the proposed new device and EzSensor XHD, the predicate device.""There are no observable radiographic findings and no quality issues with intra oral diagnostic images provided by both sensors.""The proposed device produces overall better definition and grayscale of bony and soft tissue images.""In conclusion, both the proposed new device and the predicate device produced radiographic images with adequate quality for intra oral diagnosis in terms of resolution and anatomic details."
    Detective Quantum Efficiency (DQE) (6 lp/mm)0.258 (Better than predicate's 0.204)
    Modulation Transfer Function (MTF) (3 lp/mm)0.889 (Better than predicate's 0.685)
    Noise Power Spectrum (NPS)Demonstrated better performance outcome than predicate. (Specific value not provided)
    Maximum Resolution (lp/mm)33.8 (Same as predicate due to same pixel pitch)
    Electrical Safety (IEC 60601-1 Series)Compliance demonstrated.
    Electromagnetic Compatibility (IEC 60601-1-2)Compliance demonstrated.
    Software Function (FDA Guidance)Development followed "Content of Premarket Submissions for Device Software Functions." Provides "basic level of documentation for the firmware."
    Cybersecurity (FDA Guidance)Development, documentation, and testing followed "Cybersecurity in Medical Devices..." guidance.
    Pediatric Information (FDA Guidance)Development followed "Pediatric Information for X-ray Imaging Device Premarket Notifications" guidance.
    Mechanical Durability (Drop & Vibration, etc.)Performed, risks analyzed and mitigated (e.g., stainless-steel frame, soft silicon exterior for USB connector).

    Study Information (Based on Available Text)

    1. Sample size used for the test set and the data provenance:

      • The document states "The clinical images obtained from the X Sensor and EzSensor XHD were reviewed and rated comparatively."
      • Specific sample size for the clinical images reviewed is NOT provided.
      • Data provenance (country of origin, retrospective/prospective) is NOT provided. Given it's a 510(k) for a device like an X-ray sensor, the "test set" likely refers to physical images generated during bench testing and some limited clinical image capture, rather than a large dataset for AI/ML validation.
    2. Number of experts used to establish the ground truth for the test set and the qualifications of those experts:

      • The document states "The clinical images obtained from the X Sensor and EzSensor XHD were reviewed and rated comparatively."
      • The number of experts and their qualifications are NOT specified. This phrasing suggests a qualitative human review of generated images to ensure diagnostic utility.
    3. Adjudication method (e.g. 2+1, 3+1, none) for the test set:

      • Adjudication method is NOT specified. The review appeared to be a comparative assessment of image quality.
    4. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:

      • NO MRMC study was performed or discussed. This device is an X-ray sensor, not an AI-assisted diagnostic tool in the sense of an algorithm interpreting images for a human. It provides the images.
    5. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:

      • This is NOT applicable. The "device" is the sensor itself, which captures images. There is no mention of an algorithm that performs standalone diagnostic interpretations.
    6. The type of ground truth used (expert consensus, pathology, outcomes data, etc.):

      • For the image quality assessment, the "ground truth" seems to be clinical utility/diagnostic adequacy as judged by human review of images generated by both the new device and the predicate device. Quantitative metrics (DQE, MTF, NPS) also served as objective performance measures.
    7. The sample size for the training set:

      • NOT applicable/NOT provided. This document describes a medical device, an X-ray sensor, not an AI/ML algorithm that requires a "training set" in the context of machine learning. The "training" for such a device would be its engineering and design optimization.
    8. How the ground truth for the training set was established:

      • NOT applicable/NOT provided. As above, there's no mention of a machine learning training set or associated ground truth.

    Summary of Limitations:

    The provided document is a regulatory submission for an X-ray sensor. It focuses on demonstrating substantial equivalence to a predicate device based on technical specifications, image quality, and regulatory compliance (electrical safety, EMC, software documentation, cybersecurity). It does not describe an AI/ML diagnostic algorithm or any studies related to its performance, and therefore cannot answer the specific questions posed about AI/ML acceptance criteria and validation.

    Ask a Question

    Ask a specific question about this device

    K Number
    K241649

    Validate with FDA (Live)

    Device Name
    DUO1 and DUO2
    Manufacturer
    Date Cleared
    2024-07-05

    (28 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DUO Sensors are USB driven intraoral sensors which are intended to acquire intraoral radiographic images. The DUO Sensors shall be operated by trained healthcare professionals, who are educated and competent to perform the acquisition of intraoral radiographs.

    The DUO Sensors can be used either in combination with special positioning devices to facilitate positioning and alignment with the X-ray beam or they may also be positioned by hand with the assistance of the patient.

    The DUO sensors are intended for any dental practice that uses X-ray equipment for intraoral diagnostic purposes. DUO sensors can be used by trained dental professionals for patients receiving intraoral X-ray examinations and procedures for capturing digital X-ray images. Captured digital X-ray images can be used for examinations and diagnostic purposes with the help of optional image analysis software. The optional image analysis software is not part of this submission. DUO sensors can be used with dental positioning devices and holders to assist with aligning an X-ray source beam with the sensor and anatomy.

    Device Description

    The DUO sensors are USB-driven digital X-ray sensors designed for health care professionals who are already acquainted with the standard procedures for acquiring dental intraoral radiographs. Digital X-ray imaging is an aide for diagnosis and should always be confirmed by the doctor using appropriate additional diagnostic aides, professional judgment, and experience.

    The DUO Sensors are indirect converting X-ray detectors. A scintillating material converts the incident Xrays into visible light, this light is coupled optically to a CMOS technology light detection imager, and then converted to digital data.

    The design of the sensor assembly supports the automatic detection of incident X-rays to generate digital images for intraoral applications, once armed via a software command. The digital image created is immediately visible on the screen of a personal computer connected to the DUO sensor through the standard USB port. For DUO sensors to be used in a dental practice, an optional image analysis software will be necessary. Image analysis software is not part of the submission. DUO captured X-ray images are suitable for recognition of normal anatomical structures, dental pathologies, and abnormal conditions.

    The DUO sensors support USB2.0 connectivity to computers using a dedicated electronic assembly and a sensor software driver. Functions of the DUO sensors are controlled by software drivers and utilities support sensor activation and settings.

    The DUO sensors are manufactured with the same device firmware as the predicate device, Brasseler GEM.

    AI/ML Overview

    This submission describes a dental digital X-ray sensor, DUO1 and DUO2, which is substantially equivalent to the predicate device, Brasseler GEM.

    Here's the breakdown of the acceptance criteria and supporting study details:

    1. Table of Acceptance Criteria and Reported Device Performance

    The FDA submission for K241649 is a 510(k) premarket notification, which relies on demonstrating substantial equivalence to a legally marketed predicate device rather than setting specific quantifiable acceptance criteria for novel claims. Therefore, the "acceptance criteria" here refer to demonstrating comparable performance to the predicate device (Brasseler GEM) for key technical aspects.

    Acceptance Criteria (Demonstrates Substantial Equivalence to Brasseler GEM)Reported Device Performance (DUO1 and DUO2)
    Mechanical/Physical Equivalence
    Sensor Exterior SizesDUO1: 36.36 mm x 24.53 mm (Same as Brasseler GEM) DUO2: 41.80 mm x 30.48 mm (Same as Brasseler GEM)
    Sensor Imaging SizesDUO1: 30.26 mm x 20.32 mm (Same as Brasseler GEM) DUO2: 36.08 mm x 26.25 mm (Same as Brasseler GEM)
    Overall Imaging AreasDUO1: 615 mm² (Same as Brasseler GEM) DUO2: 947.1 mm² (Same as Brasseler GEM)
    Clipped CornersAll with four clipped corners (Same as Brasseler GEM)
    Housing BiocompatibilityIPx8 Equivalent ISO 10993-1 Biocompatible (Same as Brasseler GEM). Biocompatibility is based on the predicate device as materials/manufacturing are identical. SABIC resin used is the same as the predicate device.
    Sterilization suitabilityNot suitable for sterilization (Same as Brasseler GEM). Manufacturer recommends hygienic barrier.
    Imaging Performance Equivalence
    Pixel Size19.5 μm (Same as Brasseler GEM)
    Image Resolution (pixels)DUO1: 1539 x 1026 pixels (1.70 M pixels) (Same as Brasseler GEM) DUO2: 1842 x 1324 pixels (2.40 M pixels) (Same as Brasseler GEM)
    X-Ray Resolution (lp/mm)20 visible lp/mm (Predicate: 20+ visible lp/mm). The submission states both have a theoretical maximum resolution of 25 lp/mm. This is considered "Different" in the comparison table but is addressed as substantially equivalent in the "Meaningful Differences" section by clarifying theoretical maximums are the same.
    Dynamic Range16,384:1 (Same as Brasseler GEM)
    Technology (CMOS)CMOS (Same as Brasseler GEM)
    Scintillator TechnologyCesium Iodide (Same as Brasseler GEM)
    MTF (Modulation Transfer Function)Identical to Brasseler GEM (due to using the exact same sensor components from the same contract manufacturer).
    DQE (Detective Quantum Efficiency)Substantially equivalent to Brasseler GEM (determined by BAE Systems Imaging Solutions).
    Electrical/Software Equivalence
    Operating System CompatibilityMicrosoft Windows 10 and Windows 11 (Predicate: Windows 7 and 10). This indicates broader compatibility for later OS versions for DUO.
    Interface to PCUSB 2.0, Type A (Same as Brasseler GEM)
    Power Consumption0.8 Watts Max (Same as Brasseler GEM)
    Electrical RatingDC 5V, 350 mA max (Same as Brasseler GEM)
    Cable Length0.6m and 1.9m (Predicate: 1.9m and 2.9m). Stated that cable length has no effect on performance.
    Software FunctionalityFunctions controlled by software drivers and utilities support sensor activation and settings. Simple API for integration with existing FDA-cleared image capture/dental imaging software.
    Clinical Performance
    Visual Assessment of Clinical ImagesPerformed similar or better than the predicate device (Brasseler GEM) as evaluated by US dentists.

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set Description: The document refers to "clinical images captured with both the devices in a performance testing report which were evaluated by US dentists."
    • Sample Size: The exact number of patients or images in the clinical performance test set is not specified in the provided text.
    • Data Provenance: The images were evaluated by "US dentists." It is not explicitly stated whether the data was retrospective or prospective. Given the clinical image evaluation, it suggests real-world acquisition but the exact study design (e.g., controlled prospective collection vs. retrospective existing images) is not detailed.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    • Number of Experts: The document states that the clinical images "...were evaluated by US dentists." The exact number of dentists is not specified.
    • Qualifications of Experts: The experts are described as "US dentists." Specific qualifications such as years of experience, subspecialty (e.g., board-certified oral and maxillofacial radiologists), or academic affiliations are not provided.

    4. Adjudication Method for the Test Set

    • Adjudication Method: The document only states that images "were evaluated by US dentists." It does not describe any specific adjudication method (e.g., 2+1, 3+1 consensus, independent reads with no consensus).

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • A formal MRMC comparative effectiveness study that quantifies improvements in human reader performance (e.g., AUC, sensitivity, specificity) with AI versus without AI assistance was not performed or described. The clinical performance testing involved dentists evaluating images from both devices, implying a comparative visual assessment, but not a controlled MRMC study in the context of AI assistance. The device itself is an intraoral sensor, not an AI diagnostic tool.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    • This device (DUO sensors) is a hardware component for acquiring images, not an AI algorithm for image analysis. Therefore, a standalone algorithm performance study is not applicable in the traditional sense. The submission states, "Image analysis software is not part of the submission" and "The optional image analysis software is not part of this submission."

    7. Type of Ground Truth Used

    • For the clinical performance testing, the ground truth was based on the visual evaluation and judgment of US dentists comparing images from DUO sensors to those from the predicate Brasseler GEM. This can be considered a form of expert consensus/reader judgment on image quality and diagnostic utility, but specific "ground truth" for disease presence/absence (like pathology or outcomes data) is not explicitly detailed as this is not an AI diagnostic device. The statement "DUO captured X-ray images are suitable for recognition of normal anatomical structures, dental pathologies, and abnormal conditions" implies the images were assessed for their ability to show such features.

    8. Sample Size for the Training Set

    • The provided text does not mention a training set for the DUO sensors. As this is a hardware device (sensor) and not an AI diagnostic algorithm, a "training set" in the context of machine learning is not applicable here. The device uses established CMOS and scintillator technologies and is compared against a predicate device.

    9. How the Ground Truth for the Training Set Was Established

    • Since there is no mention of a training set for an AI algorithm, the concept of establishing ground truth for a training set is not applicable to this submission.
    Ask a Question

    Ask a specific question about this device

    K Number
    K232325

    Validate with FDA (Live)

    Device Name
    RAYSCAN a-Expert
    Manufacturer
    Date Cleared
    2024-04-18

    (259 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RAYSCAN a- P, SC, OCL, OCS panoramic X-ray imaging system with Cephalostat is an extra-oral source X-ray system, intended for dental radiographic examination of the teeth, jaw, and oral structures, to include panoramic examinations and implantology and for TMJ studies and cephalometry. Images are obtained using the standard narrow beam technique.

    Device Description

    RAYSCAN α-Expert (RAYSCAN α-P, SC, OCL, OCS) provides panoramic for scanning teeth, jaw and oral structures. By rotating the C-arm, which houses a high-voltage generator, an all-in-one Xray tube and a detector on each end, panoramic images of oral and maxillofacial structures are obtained byrecombining data scanned from different angles. Functionalities include panoramic image scanning for obtaining images of whole teeth, and a Cephalometric scanning option for obtaining Cephalic images.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the "RAYSAN α-Expert" dental X-ray system. The submission affirms its substantial equivalence to a predicate device, K142058. While it outlines several tests conducted to support this claim, it does not provide explicit acceptance criteria in a table format nor does it detail a specific study with quantitative performance metrics for a direct comparison against such criteria.

    Here's a breakdown of the information that can be extracted, and where there are gaps regarding the requested specifics:

    1. A table of acceptance criteria and the reported device performance

    The document does not provide a table of acceptance criteria with corresponding device performance metrics. Instead, it states that "All test results were satisfactory" for performance (imaging performance) testing conducted according to IEC 61223-3-4. It also mentions that "a licensed practitioner reviewed the sample clinical images and deemed them to be of acceptable quality for the intended use." This indicates a subjective assessment of image quality rather than quantitative performance against defined acceptance criteria.

    2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    • Test Set Sample Size: The document mentions that "images were gathered from all detectors of RAYSCAN α-Expert using protocols with random patient age, gender, and size" and that "Clinical imaging samples were collected from new detectors on the proposed device at the two offices where the predicate device was installed for the clinical test images." However, it does not specify the exact number of images or patients in the clinical test set.
    • Data Provenance: The images were collected "at the two offices where the predicate device was installed for the clinical test images." The manufacturer is Ray Co., Ltd. located in South Korea. It's implied these are prospective clinical images gathered for the purpose of the submission.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    • Number of Experts: "The clinical performance of RAYSCAN α-Expert were clinically tested and approved by two licensed practitioners/clinicians."
    • Qualifications of Experts: They are described as "licensed practitioners/clinicians." No specific details such as years of experience, specialization (e.g., radiologist, dentist), or board certification are provided.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    The document states, "A licensed practitioner reviewed the sample clinical images and deemed them to be of acceptable quality for the intended use." It implies individual review, but does not specify any formal adjudication method (e.g., whether the two practitioners independently reviewed images and consensus was reached, or if there was a third adjudicator in case of disagreement).

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • MRMC Study: No MRMC comparative effectiveness study is mentioned. This device is an X-ray imaging system, not an AI-assisted diagnostic tool for humans, so this type of study would not be applicable. The comparison is between the new device's image quality and the image quality of the predicate device.
    • Effect Size: Not applicable.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This refers to an X-ray imaging device, not an algorithm. Therefore, "standalone (algorithm only)" performance is not applicable. The device's primary function is image acquisition.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for the clinical image quality assessment appears to be expert opinion/consensus (from two licensed practitioners) regarding whether the images were "of acceptable quality for the intended use." There's no mention of pathology or outcomes data for establishing ground truth.

    8. The sample size for the training set

    The document mentions software validation, but this X-ray system is not described as an AI/ML device that requires a distinct "training set" in the context of machine learning model development. This question is not directly applicable to the type of device described.

    9. How the ground truth for the training set was established

    As the device is not described as involving an AI/ML model with a training set, this question is not directly applicable. The software mentioned is for saving patient and image data, inquiries, and image generation, and was validated according to FDA guidance for software in medical devices, not specific AI/ML training.

    Summary of what is present and what is missing:

    • Acceptance Criteria/Performance Table: Not provided in the requested format. General statement of "satisfactory" test results and "acceptable quality."
    • Test Set Sample Size & Provenance: Sample size not quantified. Provenance is South Korea, likely prospective.
    • Number & Qualification of Experts: Two licensed practitioners/clinicians. No further qualification details.
    • Adjudication Method: Not specified.
    • MRMC Study: Not applicable.
    • Standalone Performance: Not applicable.
    • Type of Ground Truth: Expert opinion on image quality.
    • Training Set Sample Size: Not applicable (not an AI/ML device in this context).
    • Training Set Ground Truth: Not applicable.
    Ask a Question

    Ask a specific question about this device

    K Number
    K231660

    Validate with FDA (Live)

    Date Cleared
    2023-12-20

    (196 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Digital image scanner of dental is intended to be used for scanning and processing digital images exposed on IP Imaging Plate in dental applications.

    Device Description

    Digital image scanner of dental is a dental device that scans IP Imaging plates that have been exposed in place of dental X-ray film and allows the resulting images to be displayed on the screen and stored for later recovery. It will be used by licensed clinicians and authorized technicians for this purpose. The device is an intraoral Plate Scanner, which is designed to read out intraoral Plates of the size S0, S1, S2 and S3. The intraoral plates are put into the mouth of the patient, exposed to X-rays and then are read out with the device. The read-out-process is carried out with 630-645 nm laser. The laser beam is moved across the surface of the plate by an oscillating mirror. The laser beam stimulates the top coating of the plates, which consists of X-rays sensitive material. Depending on the exposed dose, the coating emits different levels of light. These light particles are then requisitioned by an optical sensor (Photo Multiplier tube/ PMT) and transferred into an electrical output signal. This signal is digitalized and is the data for the digital X-ray image. Before the plate is discharged, the remaining data is erased by a LED-PCB. The user chooses which size of plate he must use and prepares the device by inserting the appropriate plate insert into the device. He then exposes the plate and then puts the plate directly into the insert by pushing it out of the light protection envelope. The user closes the light protection over and starts the read-out process. After the read out process the picture is transmitted to the screen, the picture can be viewed, and the IP is erased and ready to use for the next acquisition.

    AI/ML Overview

    The provided document is a 510(k) summary for a dental image scanner. It describes the device, compares it to a predicate device, and outlines the non-clinical testing performed to demonstrate substantial equivalence. However, it does not contain a detailed study proving the device meets specific acceptance criteria in the way medical imaging AI/CAD performance studies typically do, nor does it refer to a multi-reader multi-case (MRMC) study. The testing described focuses on device performance characteristics rather than diagnostic accuracy with human readers.

    Therefore, many of the requested criteria cannot be directly extracted from this document, as they pertain to clinical or human performance studies, which are explicitly stated as "not required for this submission."

    Here's the information that can be extracted or inferred, with explanations for what cannot be found:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't present a formal table of general acceptance criteria with performance results in the context of diagnostic accuracy. Instead, it lists technical performance tests and states that the "Imaging standard requirements were met" and "Laser products have passed safety test."

    Acceptance Criteria CategorySpecific Test/Parameter (if applicable)Reported Device Performance
    Electrical SafetyIEC 60601-1Passed (does not raise questions about safety effectiveness)
    Electromagnetic CompatibilityIEC 60601-1-2Passed (does not raise questions about safety effectiveness)
    Imaging PerformanceImaging standard requirements (dental X-ray), IEC 61223-3-4Met X-ray equipment imaging standard requirements
    Laser SafetyIEC 60825-1Passed safety test
    Software Verification & ValidationFDA Guidance for Software in Medical DevicesAll functions supporting system specification are proper; verification and validation properly accomplished.
    Image Plate TestImaging area, degree of attenuation, uniformity, image contrast, bit depth, spatial resolution/MTFVerified by testing
    Image Accuracy & Fidelity TestAccuracy, uniformity, image contrast, spatial resolution/MTF, image fidelityVerified by testing
    Theoretical ResolutionsNot explicitly an acceptance criterion, but mentioned17 LP/mm (compared to predicate's 10 or 33 LP/mm)
    MTF (Modulation Transfer Function)Not explicitly an acceptance criterion, but mentionedMore than 45% at 3 lp/mm
    DQE (Detective Quantum Efficiency)Not explicitly an acceptance criterion, but mentionedMore than 21.0% at 3 lp/mm

    2. Sample size used for the test set and the data provenance

    • Sample Size for Test Set: Not specified. The document refers to "image plates test" and "image accuracy and fidelity test," which are laboratory/technical performance tests, not clinical performance tests with a specific patient dataset.
    • Data Provenance: Not applicable, as no patient data (images from humans) was used for performance testing (clinical testing was not required). The tests appear to be conducted on the device itself using phantom or test patterns.
    • Retrospective/Prospective: Not applicable.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    • This information is not provided because diagnostic ground truth from expert readers was not established or used, as clinical testing was not required. The "ground truth" for the technical tests would be the known properties of the phantoms/test patterns used.

    4. Adjudication method for the test set

    • Not applicable, as no expert reading or adjudication of diagnostic findings was involved.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    • No, an MRMC comparative effectiveness study was not done. The document explicitly states under section 7, "Clinical Testing: Clinical testing was not required for this submission." This type of study would fall under clinical testing.
    • Effect Size: Not applicable as no such study was performed.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    • The device is a hardware scanner, not an AI/CAD algorithm. The "Image Reading and Checking Testing" falls under standalone performance, as it assesses the device's ability to accurately scan and process images. However, this is about the quality of the image output from the scanner, not the diagnostic performance of an AI algorithm on those images.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    • For the technical performance tests ("Image Reading and Checking Testing"), the ground truth would be established by the known characteristics of the test patterns, phantoms, and calibrated equipment used for measurement. It is not expert consensus, pathology, or outcomes data, as these relate to clinical diagnostic accuracy, which was not assessed.

    8. The sample size for the training set

    • Not applicable. This device is a scanner, not an AI or machine learning algorithm that requires a training set. The "software verification and validation testing" refers to typical software engineering V&V processes, not machine learning model training.

    9. How the ground truth for the training set was established

    • Not applicable, as there is no training set for this device (it's not an AI/ML algorithm).
    Ask a Question

    Ask a specific question about this device

    K Number
    K233053

    Validate with FDA (Live)

    Date Cleared
    2023-11-21

    (57 days)

    Product Code
    Regulation Number
    872.1800
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The DEXIS sensor is a USB- driven digital sensor which is intended to acquire dental intra- oral radiographic images. The DEXIS sensor shall be operated by healthcare professionals, who are educated and competent to perform the acquisition of dental intra-oral radiographs. The DEXIS sensor can be used either in combination with special positioning devices to facilitate positioning and aligmment with the x-ray beam or it may also be positioned by hand with the assistance of the patient.

    Device Description

    The DEXIS Sensors are an indirect converting x-ray detector, e.g. incident x-rays are converted by a scintillating material into (visible) light, this light is coupled optically to a light detection imager based on CMOS technology. The design of the sensor assembly supports the automatic detection of the incident x-rays to generate digital images for dental intra oral applications. The DEXIS Sensors support USB2.0 and USB 3.x connectivity to personal computers using a dedicated electronic assembly and a sensor software driver. The software and firmware for the subject device are similar to the software and firmware for the predicate device and both have a Moderate level of concern. The software performs only basic functions of image capture and transfer to a computer. The software does not perform any medical image manipulation such as image enhancements as these are expected to be performed in the dental viewing software(s) used in conjunction with the subject device.

    The subject device DEXIS sensor refers to the dental intra-oral detector. The x-ray generator (an essential component for a fullyfunctional dental x-ray system) is not part of the submission.

    AI/ML Overview

    The provided text is a 510(k) summary for the DEXIS Ti2 Intraoral Sensor, DEXIS IXS Size 1 Intraoral Sensor, and DEXIS IXS Size 2 Intraoral Sensor.

    Here's an analysis of the acceptance criteria and study information:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document does not explicitly present a table of acceptance criteria with specific numerical targets and corresponding reported device performance values in a side-by-side format. However, it does state an important performance metric:

    Acceptance Criteria (Implicit)Reported Device Performance
    X-ray Resolution of 20+ visible lp/mmAchieved X-ray Resolution of 20+ visible lp/mm
    Maximum resolution of 22 lp/mmAchieved maximum resolution of 22 lp/mm (based on MTF analysis)

    The document also implies that the device must conform to various international and FDA recognized consensus standards for medical electrical equipment, electromagnetic disturbances, usability, biological evaluation, risk management, and evaluation of imaging performance of dental X-ray. The conclusion states that non-clinical performance bench testing was conducted to determine conformance to these standards, implying successful adherence without providing specific numerical thresholds for each.

    2. Sample Size Used for the Test Set and Data Provenance

    The document explicitly states: "Clinical data is not needed to characterize performance and establish substantial equivalence. The non-clinical test data characterize all performance aspects of the device based on well-established scientific and engineering principles. Clinical testing has not been conducted on this product."

    Therefore, there was no clinical test set, sample size, or data provenance (country of origin, retrospective/prospective) for a study involving patients or real-world clinical data. The evaluation was based on non-clinical bench testing.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    Since no clinical testing was performed, the concept of "ground truth" established by experts in the context of interpreting medical images from a test set does not apply. The performance was evaluated against technical specifications and standards using bench tests.

    4. Adjudication Method for the Test Set

    Not applicable, as no clinical test set was used that would require adjudication of expert interpretations.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No MRMC study was conducted. The document explicitly states that clinical testing has not been conducted. This means there is no data on how human readers might improve with or without AI assistance, as the device is a dental intraoral sensor, not an AI-powered diagnostic tool for interpretation.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    Not applicable in the typical sense of an AI algorithm. The device itself is an imaging sensor. The "algorithm" here refers to the internal processing of the sensor to acquire and transfer digital images, not an AI for diagnosis. The performance evaluation was of the sensor's technical capabilities (e.g., resolution, MTF).

    7. Type of Ground Truth Used

    For the non-clinical bench testing, the "ground truth" would be the known physical properties and characteristics being measured, as defined by the standards and specifications. For instance, the X-ray resolution was measured against a known standard or ideal resolution target.

    8. Sample Size for the Training Set

    Not applicable. The DEXIS sensor is a hardware device for acquiring images and is not an AI algorithm that undergoes a "training" phase with a dataset.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there was no training set for an AI algorithm.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 21