Search Filters

Search Results

Found 198 results

510(k) Data Aggregation

    K Number
    K252976

    Validate with FDA (Live)

    Date Cleared
    2025-12-18

    (92 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    18 - 150
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Park Dental Nylon MAD is intended to reduce or alleviate snoring and mild to moderate obstructive sleep apnea (OSA) in adults.

    Device Description

    The Park Dental Nylon Mandibular Advancement Device (MAD) is a custom-made, removable oral appliance consisting of two intraoral trays connected by an adjustable interlocking rigid rod. It is intended for use in patients diagnosed with Obstructive Sleep Apnea (OSA) and functions by advancing the lower jaw (mandible) during sleep to increase the pharyngeal airway space. This advancement reduces airway obstruction, minimizes snoring, and promotes improved sleep quality and reduced jaw tension.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253868

    Validate with FDA (Live)

    Device Name
    QuietLab Pro
    Manufacturer
    Date Cleared
    2025-12-05

    (2 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    18 - 120
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Intended as an aid in the reduction of snoring for adults at least 18 years old.

    Device Description

    The QuietLab Pro Anti-Snoring Mouthpiece is a reusable, over-the-counter oral appliance intended to reduce or eliminate snoring by gently repositioning the lower jaw to maintain an open upper airway during sleep. The device achieves this effect through a precision-adjustable mandibular advancement mechanism that minimizes airway collapse and reduces tissue vibration—the primary cause of snoring.

    Scientific Basis and Mechanism of Action:
    Snoring typically occurs when the muscles around the throat relax during sleep—especially during REM—causing a partial collapse of the airway. As air moves through this narrowed passage, it vibrates the soft tissues, producing the characteristic sound of snoring. The QuietLab Pro addresses this by:

    • Advancing the lower jaw (mandible) slightly forward using a precision-fit tray and hinge system.
    • Increasing pharyngeal space to prevent airway collapse.
    • Promoting steady airflow and reducing soft tissue vibration during sleep.

    Device Design and Key Performance Characteristics:
    The QuietLab Pro is comprised of three primary components, designed for comfort, adjustability, and durability:

    1. Central Part - Structural Component

    • Thermoplastic Polyurethane for flexible hinge zones.
    • Provides structural support, maintains upper/lower tray alignment, and enables lateral jaw movement during sleep.

    2. Central Part – Hard Inserts & Attachment Pins (4-Pin Diamond-Shaped Sliding Mechanism)

    • Made of Polycarbonate (PC) for rigidity
    • Offers incremental, repeatable adjustment to tailor the mandibular position to the user's anatomy.
    • Prevents unintentional shifting during use, improving comfort and treatment consistency.

    3. Upper and Lower Trays (Anatomical Trays)

    • Fabricated from Thermoplastic Elastomer
    • Anatomically contoured to fit over dental arches without molding.
    • The lower tray allows for up to 9 mm of mandibular advancement via a 25-position micro-adjustment system.

    Material Composition:
    All components are made of biocompatible, medical-grade materials tested for prolonged mucosal contact (per ISO 10993-1):

    • PC (Polycarbonate) – Provides strength and stability.
    • TPU (Thermoplastic Polyurethane) – Allows for flexibility at hinge and contact points.
    • TPE (Thermoplastic Elastomer) – Ensures soft tissue compatibility and user comfort.

    The device is manufactured in an ISO-certified facility under strict quality controls and is compliant with RoHS material safety standards.

    The carrying-case material is indirect patient contact only.

    Physical Properties:

    • Non-sterile, reusable device intended for single-patient use.
    • Designed for home use during sleep.
    • Accommodates diverse dental anatomies through flexible materials and an Adaptive Fit system.
    • Lightweight, with integrated grooves to promote airflow and minimize saliva buildup.

    Function and Adjustability:

    • Upper Tray: Provides upper jaw stabilization.
    • Lower Tray: Delivers adjustable mandibular advancement.
    • Adjustment Range: Up to 9 mm total advancement with fine control.
    • Custom Fit: No boiling or molding required; adjustment is tool-free and user-controlled.
    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252161

    Validate with FDA (Live)

    Device Name
    Hushd Avera
    Date Cleared
    2025-11-25

    (138 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Hushd Avera device is intended to reduce or alleviate snoring.

    Device Description

    The Hushd Avera device is a removable intraoral non-patient specific device used for treating snoring. The device consists of multiple trays that fit over the upper and lower teeth. When the upper and lower tray engages, the device functions as a mandibular repositioner holding the mandible forward during sleep thus preventing the tongue and soft tissues of the throat from collapsing into the airway.

    The Hushd Avera device is a "Boil and Bite" device where both the upper and lower trays are constructed out of moldable soft ethylene vinyl acetate (EVA) material with rigid polypropylene (PP) outer shells.

    Hushd Avera consists of one upper and two lower trays. Each upper tray contains a trapezoidal block on each side of the posterior to mate with the lower tray. An identification mark is placed on the blocks. The blocks and the outer shell of the upper tray are molded in one piece.

    Each lower tray contains a vertical dorsal fin on each side of the posterior to serve as mating mechanism. The fins are triangular shaped at approximately 12.0mm(H) x 12.0mm(W) x 2.5mm(D). The mating surface of the fins are flat to ensure stable positioning of the upper and lower trays against each other. An identification mark is placed on the dorsal fins. The dorsal fins and the outer shell of the lower tray are molded in one piece.

    There are no additional clip-on mechanisms connecting the upper and lower trays.

    Relative to the upper tray (U), the first lower tray (L1) is positioned 1.0mm forward from an edge-to-edge position, while the upper tray (U) and the second lower tray (L2) have an additional 2.0mm protrusion. The user can select between the two positions as needed.

    Therefore, the maximum protrusion is +3mm from edge to edge while using L2.

    There are no variants for this device and it is available only in one configuration.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252525

    Validate with FDA (Live)

    Device Name
    AIO Breathe
    Manufacturer
    Date Cleared
    2025-11-06

    (87 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The AIO Breathe is intended to reduce snoring and to treat mild and moderate obstructive sleep apnea in children 6-17 years of age who are diagnosed with snoring and/or mild or moderate obstructive sleep apnea.

    Device Description

    AIO Breathe consists of two separate intraoral trays (upper, lower) that are customized to fit over all the teeth. The device is manufactured at AIOMEGA facilities using additive manufacturing with Stereolithography (SLA) 3D printing technology that builds the device from biocompatible resins. The customized trays are fabricated based on intraoral scans provided by the dentist and the dentist's prescription.

    AIO Breathe features right and left protrusive flanges on the buccal sides of the upper tray. These flanges engage with corresponding right and left vertical flanges featured on the buccal sides of the lower tray. This engagement repositions the jaw to reflect the dentist's prescribed anterior mandibular advancement.

    Additionally, mandibular plateaus, as prescribed by the dentist, featured on the right, and left occlusal cranial surfaces of lower tray, guide the mandible downward, thus opening the anterior airway. The plateaus and flanges allow vertical opening of the jaw (jaw is not fixed in a single position) and work together to maintain advancement in open and closed mouth positions. This design feature allows more room and creates traction for the tongue to migrate forward. The resulting mechanical protrusion increases the patient's pharyngeal space, improving their ability to exchange air, thereby reducing the tendency to snore and alleviating signs of obstructive sleep apnea.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K252698

    Validate with FDA (Live)

    Date Cleared
    2025-11-03

    (68 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The NightGuard Aire Max is a removable medical device that is fitted in the patient's mouth and is intended to reduce or alleviate snoring and mild to moderate obstructive sleep apnea (OSA) in adults.

    Device Description

    The NightGuard Aire Max is a custom made intraoral appliance intended to treat mild to moderate Obstructive Sleep Apnea (OSA) and habitual snoring. The device's primary function is mandibular advancement, which repositions the lower jaw forward during sleep. This forward positioning helps reduce airway obstruction, promoting improved airflow and alleviating symptoms associated with snoring and Obstructive Sleep Apnea (OSA). The device comprises two custom made trays, each featuring two embedded button hooks on each side, and a pair of elastic bands. The hooks are positioned at a distance of 20mm apart from the upper tray hook to the bottom tray hook. These hooks serve as secure attachment points for the elastic bands, which serve to keep the trays in place. The bands are available in four different sizes (20mm, 19mm, 18mm, and 17mm) ensuring a functional, customizable fit for each patient. The upper and lower trays each support a structural element, and the structural elements together maintain an open airway. In particular, the lower tray features an anterior platform with a bump elevation located at a position corresponding to a patient's central incisors. This bump serves as a specific point of contact to maintain an open airflow space, supporting the functionality of the anterior platform. The upper tray includes a flat plane at a position corresponding to the patient's central incisors, which works in conjunction with the bump elevation on the lower tray to facilitate airflow during use. The upper and lower trays are manufactured using one of three FDA-cleared, biocompatible materials: Dental LT Comfort Resin, KeySplint Hard Resin, or KeySplint Soft Resin, each of which is suitable for long-term contact with oral tissues.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K253355

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-10-29

    (29 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Difiney Advanced Anti Snoring Device 4.0 is intended to help reduce snoring in people 18 years of age or older.

    Device Description

    The Difiney Advanced Anti Snoring Device 4.0 is designed to reduce snoring by gently repositioning the lower jaw forward, which opens the airway and allows for smoother airflow during sleep. By adjusting the position of the lower jaw, the device helps prevent the throat tissues from collapsing and blocking airflow, which is a common cause of snoring.

    The 4.0 version is customizable, allowing users to set the lower jaw advancement up to 6mm, providing a personalized fit for maximum comfort and effectiveness. This forward positioning also reduces vibrations in the airway, which are often responsible for the snoring sound.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251784

    Validate with FDA (Live)

    Device Name
    Hushd Pro Z-Link
    Date Cleared
    2025-10-24

    (135 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Hushd Pro Z-Link device is intended to reduce or alleviate snoring and mild to moderate obstructive sleep apnea (OSA) in adults.

    Device Description

    The Hushd Pro Z-Link device series are removable intraoral patient-specific device intended for the treatment of snoring and mild to moderate obstructive sleep apnea. The device consists of custom-made maxillary and mandibular splints that fit over the upper and lower teeth, and are connected via a pair of detachable rigid connectors. When linked, the splints function as a mandibular repositioner by holding the lower jaw in a forward position during sleep, thereby preventing the tongue and soft tissues from collapsing into the airway.

    Each device consists of one maxillary and one mandibular splint, designed and manufactured using 3D printing technology. The splints incorporate a pair of integrated studs that are located around the canine area for the maxillary splint and around the first molar area for the mandibular splint. These studs interface with slots on the detachable connectors to securely link the two splints together. This configuration permits the mandible to advance from the baseline position, offering improved patient comfort.

    Titration is achieved by replacing the connectors with another pair of a different size. The connectors are available in 1.0 mm incremental lengths, allowing progressive mandibular advancement according to patient tolerance and clinical need. A standard set includes six pairs of connectors, ranging from -1 mm to +5 mm protrusion, while an extended set ranging from +6 mm to +10 mm is available upon request, providing a maximum mandibular protrusion of 10 mm.

    The connectors are not elastic and do not contain adjustment mechanisms such as pistons, screws, straps, or repositioning elastics. The rigid connectors are manufactured with medical grade nylon PA12 using commercial injection molding process and are marked for easy identification.

    The splints of this device are manufactured using selective laser sintering (SLS) 3D printing with EOS PA2200 polyamide (nylon) PA12 material. This material offers excellent mechanical properties, long-term stability, and has a history of safe use in oral medical devices. The manufacturing process includes mechanical or chemical polishing, cleaning, and rigorous quality control prior to packaging.

    The Hushd Pro Z-Link is available for prescription only and designed based on optical or physical impressions taken by a licensed healthcare provider. The splints and connectors are designed exclusively by the device manufacturer and its authorized partners to ensure consistent quality and performance.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K251628

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-10-22

    (147 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Mandibular Advancement Device is designed to advance the user's lower jaw and maintain this position during use, opening the airway to reduce snoring during sleep. It is intended for adults with at least 18 years old.

    Device Description

    The L07 Mandibular Advancement Device is an intraoral device that is used to maintain the lower jaw in a forward position to increase pharyngeal space so as to improve the ability to exchange air and decrease air turbulence, a causative factor in snoring.

    The L07 Mandibular Advancement Device include three types: Type A, Type B, Type C. Each type includes one upper tray and one lower tray. The upper tray of these three types are the same, while they are only different in lower tray. By combining upper tray with different lower tray, the device can be used for advancing lower jaw from 0mm to 6mm.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K250028

    Validate with FDA (Live)

    Date Cleared
    2025-10-03

    (270 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Anti snore mouthpiece is intended as an aid in the reduction of snoring for adults at least 18 years old.

    Device Description

    Anti snore mouthpiece is an intraoral device composed of a maxillary and mandibular tray assembled to position the mandible forward relative to the maxilla to increase users' pharyngeal space and improve the ability to exchange air and decreases air turbulence, a causative factor in snoring.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    K Number
    K243752

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2025-09-17

    (286 days)

    Product Code
    Regulation Number
    872.5570
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    to reduce nighttime snoring and mild to moderate obstructive sleep apnea in adults

    Device Description

    The Double Tube Herbst appliance consists of upper and lower base appliances connected on each side by a telescopic apparatus that advances the mandible. Each telescopic apparatus is loosely but securely attached to wire loops formed at the ends of retentive anchors embedded in the acrylic on the outer (buccal) surfaces of the upper and lower base appliances. A telescopic apparatus consists of a double tube telescopic assembly that is attached to the back end of the upper wire loop; and a rod that is attached to the front end of the lower wire loop. The double tube telescopic assembly consists of a short internally threaded tube welded in parallel onto the back of a long straight tube in which the rod slides. The short internally threaded tube is adjustably attached to the back end of the upper wire loop by engaging the externally threaded lower end of a connector, the upper end of which ends in a helix that is twisted around the upper wire loop. The rod that slides in and out of the long tube is loosely but securely attached to the wire loop on the front end of the lower retentive anchor. The lengths of the telescopic assemblies can be adjusted in 1/2 mm increments along a range of 15 mm by disengaging the telescopic components, rotating the double tube assembly around the connecting arm, and sliding the rod back into the long tube to lock in the adjustment.
    The Double Tube Herbst appliance is worn while sleeping to keep the mandible in a forward position prescribed by the treating dentist to reduce nighttime snoring and mild to moderate obstructive sleep apnea in adults. The customized appliance is inserted and removed by the patients every night, and it is adjusted by the prescribing dentist.

    AI/ML Overview

    N/A

    Ask a Question

    Ask a specific question about this device

    Page 1 of 20