Found 2 results

510(k) Data Aggregation

    K Number
    K962609

    Validate with FDA (Live)

    Date Cleared
    1996-08-30

    (58 days)

    Product Code
    Regulation Number
    866.2660
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Vitek GNI+ Card is intended to be used in conjunction with the Vitek System for the automated identification of microorganism of the family Enterobacteriaceae. In addition, a select group of glucose non-fermenting gram-negative bacteria, and members of the family Vibrionaceae can be identified. In addition to the organisms currently claimed with the GNI Card, the GNI+ Card has added the following 13 new organism claims:

    • Aeromanas veronii biovar veronii Budvicia aquatica Burkholdenia mallei CDC Group EO-2 Chromobacterium violaceum Edwardsiella hoshinae Klebsiella ornithinolytica Moellerella wisconsensis Rahnella aquatilis Shigella boydii/flexneri Sphingobacterium spiritivorum Sphingobacterium thalpophilum Yokenella regensburgei (Koserella trabulsii)
    Device Description

    The GNI+ Card consists of a plastic card with thirty wells that contain 28 dehydrated biochemical broths, one negative control broth and one growth control broth. The broths are re-hydrated with a saline suspension of a pure culture isolated from a patient specimen. The GNI+ Card performs a variety of conventional and non-conventional biochemical tests that are based on established biochemical methods. Organism identification usually requires between 2-12 hours of incubation on the automated Vitek System.

    AI/ML Overview

    Here's an analysis of the provided 510(k) summary, structured to address your specific questions:

    1. Table of Acceptance Criteria and Reported Device Performance

    The acceptance criteria are not explicitly stated as numerical targets in this summary. However, based on the presented data, we can infer the implicit performance expectations.

    Acceptance Criteria (Inferred)Reported Device Performance
    High rate of correct identification (developmental phase)96.9% correctly identified in non-clinical development
    High rate of correct identification (challenge organisms)94.7% correctly identified in clinical challenge study
    High overall correlation with existing GNI Card97.4% overall correlation in clinical trials
    No adverse discrepancies"No adverse discrepancies were noted"
    Software performance meets specifications"tested extensively in-house" and "at clinical trial sites" to a "detailed protocol" and "designed, validated and tested according to established written procedures"

    2. Sample Size Used for the Test Set and Data Provenance

    • Test Set (Clinical Trials - Challenge Organisms): 106 challenge organisms. These were "different isolates than those used to develop the database." The provenance is internal to bioMérieux Vitek.
    • Test Set (Clinical Trials - Routine Clinical Isolates): "A minimum of 130 routine clinical isolates." These were "from fresh patient cultures as they were randomly submitted to the laboratory." The country of origin is not specified but implied to be the locations of the three clinical sites. The data is prospective for these isolates.
    • Test Set (Clinical Trials - Investigator's Stock Collection): "Thirty to fifty isolates from the investigator's stock collection." The provenance is internal to the clinical sites. This would likely be retrospective, drawing on existing collections.
    • Test Set (Non-Clinical Development Trials): 2974 strains were used to develop the GNI+ database. These were "well characterized, having been previously identified." The provenance is internal to bioMérieux Vitek. This data is retrospective.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not specify the number of experts or their qualifications for establishing ground truth in the clinical trials. It relies on established methods and their outcomes.

    4. Adjudication Method for the Test Set

    The adjudication method described is a hierarchical approach:

    • Initial Comparison: GNI+ card results were directly compared to the current Vitek GNI Card.
    • First Level Discrepancy Resolution: Discrepancies between GNI+ and GNI were resolved using:
      • API 20E (for fermenters)
      • API NFT (for non-fermenters)
    • Second Level Discrepancy Resolution: Further discrepancies, or if GNI+ identified a species not claimed by the GNI Card or API methods, were confirmed with "conventional biochemical testing."

    This method is essentially a form of expert-guided consensus, where established, validated methods (API strips, conventional biochemicals) serve as the "experts" for adjudication.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs without AI Assistance

    No, an MRMC comparative effectiveness study involving human readers or AI assistance in that context was not performed. This device is an automated identification system, not an AI-assisted diagnostic tool that aids human interpretation. The "AI" in this context refers to the automated analysis and identification algorithm, not a system designed to improve human reader performance.

    6. If a Standalone (i.e. algorithm only without human-in-the-loop performance) Was Done

    Yes, a standalone performance evaluation of the algorithm was conducted. The entire premise of the GNI+ Card and Vitek System is automated identification. Both the "Non Clinical Development Trials" (96.9% correct identification) and the "Clinical Trials" (94.7% correct on challenge set, 97.4% overall correlation) represent standalone performance of the device without human interpretation of the raw biochemical reactions. Humans prepare the sample, but the identification itself is automated.

    7. The Type of Ground Truth Used (expert consensus, pathology, outcomes data, etc.)

    The ground truth for the clinical trials was established through:

    • Reference Devices: The current Vitek GNI Card.
    • Established Commercial Kits: API 20E and API NFT.
    • Conventional Biochemical Testing: Standard laboratory methods for bacterial identification.

    This represents a form of expert consensus based on established laboratory methods and reference technologies, rather than direct human expert consensus alone or pathology/outcomes data.

    8. The Sample Size for the Training Set

    The "Non Clinical Development Trials" section states: "A panel of 2974 strains were used to develop the GNI + database." This panel served as the training set for the algorithm that analyzes the biochemical reactions.

    9. How the Ground Truth for the Training Set Was Established

    The ground truth for the 2974 strains used in the training set (to develop the GNI+ database) was established by their prior identification using:

    • The GNI Card (existing device)
    • API strips (commercial reference method)
    • Conventional biochemicals (standard laboratory methods)

    These organisms were described as "well characterized," implying their identities were confidently established through these recognized methods prior to their use in database development. This also constitutes expert consensus based on established laboratory methods and reference technologies.

    Ask a Question

    Ask a specific question about this device

    K Number
    K961042

    Validate with FDA (Live)

    Date Cleared
    1996-05-30

    (77 days)

    Product Code
    Regulation Number
    866.2660
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Rapid identification of non-fastidious aerobic and facultatively anacrobic gram-negative bacilli from human clinical specimens

    Device Description

    Not Found

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and study for the MicroScan® Rapid Gram-Negative Identification Type 3 Panel:

    1. Table of Acceptance Criteria and Reported Device Performance

    The document doesn't explicitly state quantitative acceptance criteria in a dedicated section. However, it implicitly defines successful performance based on comparison with the predicate device (API 20E System) and supplemental conventional methods.

    Acceptance Criteria (Implied)Reported Device Performance
    High agreement with predicate device (API 20E System) and97.1% combined final agreement (species level, high and low probabilities)
    supplemental tube methodologies for identification of gram-negativewith API 20E System identifications + supplemental tube methodologies.
    isolates.
    High reproducibility of results.>95% agreement with expected results.
    Acceptable Quality Control (QC) performance.QC performance was acceptable for both systems during the clinical trial.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set: 405 fresh and stock gram-negative isolates.
    • Data Provenance: The text states, "Efficacy testing was conducted with a total of 405 fresh and stock gram-negative isolates at two (2) external sites." This indicates the data was collected prospectively (fresh isolates) and retrospectively (stock isolates) from clinical settings, likely within the country where the external sites were located (which isn't specified but generally implied to be the US for FDA submissions).

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications of Those Experts

    The document does not specify the number of experts used or their qualifications for establishing the ground truth. It states that "Isolates meeting a pre-defined criteria were either repeated and/or were arbitrated using conventional tube methodologies."

    4. Adjudication Method for the Test Set

    The adjudication method used was a form of arbitration. When the initial MicroScan Rapid Gram-Negative Identifications were compared with API 20E System identifications, isolates that did not meet a "pre-defined criteria" were "either repeated and/or were arbitrated using conventional tube methodologies." This suggests a process where discrepancies or uncertain results were resolved by referring to conventional laboratory methods, which often involves expert interpretation.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study Was Done, If So, What Was the Effect Size of How Much Human Readers Improve with AI vs Without AI Assistance

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not conducted. This device is an automated microbiological identification system, not an AI-assisted diagnostic tool for human readers. Therefore, the concept of human readers improving with or without AI assistance does not apply.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Yes, a standalone performance study was done. The entire efficacy testing described (comparison of MicroScan RNID Type 3 panel results to API 20E System and supplemental tube methodologies) evaluates the performance of the device itself ("algorithm only") without an explicit "human-in-the-loop" component for interpretation during the initial identification phase. The "arbitration" step using conventional methods would involve human expert judgment, but this is a secondary step for discrepancy resolution, not primary interpretation of the device's output.

    7. The Type of Ground Truth Used

    The ground truth was established by:

    • Comparison to a predicate device: API 20E System identifications.
    • Arbitration with conventional tube methodologies: These are generally considered the gold standard or reference methods in microbiology for definitive identification when discrepancies arise. This implies a form of expert-driven reference standard based on established laboratory practices, rather than pathology or outcomes data.

    8. The Sample Size for the Training Set

    The document does not provide information about a separate "training set" or its sample size. The description focuses on "efficacy testing" against historical methods. This suggests a validation study rather than a machine learning model that would require a distinct training phase.

    9. How the Ground Truth for the Training Set Was Established

    Since no separate training set is mentioned in the provided text, information on how its ground truth was established is not available. The efficacy study serves as the primary validation of the device's performance against established microbiological identification methods.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1