Search Results
Found 77 results
510(k) Data Aggregation
(189 days)
Ask a specific question about this device
(60 days)
The Persona Partial Knee system is limited to the medial tibiofemoral compartment of the knee intended for patients with painful and/or disabling knee joints due to the following indications:
- Noninflammatory degenerative joint disease (NIDJD), e.g., osteoarthritis, avascular necrosis;
- traumatic arthritis;
- previous tibial condyle or plateau fractures with loss of anatomy or function;
- varus deformities; and
- revision of the articular surface of a previously implanted Persona Partial Knee System providing that the tibial plate locking mechanism is not compromised and the femoral and tibial plate components remain well fixed and undamaged.
The Persona Partial Knee System is a single use implant intended for implantation with bone cement.
The purpose of this submission is to add a line extension of Size B to the Persona Partial Knee system (PPK). The Persona Partial Knee System is a partial knee replacement for the medial compartment of the knee and is modular in design consisting of three components: a unicondylar cobalt-chromium-molybdenum (Co-Cr-Mo) alloy femoral component, a unicondylar titanium (Ti-6Al-4V) alloy tibial tray, and a unicondylar articular surface manufactured using the previously cleared Vivacit-E ® Vitamin-E Highly Crosslinked Polyethylene (VEHXPE).
This FDA 510(k) clearance letter for the Persona Partial Knee is for a medical implant (a knee replacement prosthesis), not an AI/software device. Therefore, the information requested in the prompt, such as "number of experts used to establish ground truth" or "multi reader multi case (MRMC) comparative effectiveness study," is not relevant to this type of device.
The clearance is based on the substantial equivalence principle, meaning the device is shown to be as safe and effective as a previously cleared predicate device. The performance data mentioned in the document refers to non-clinical testing (e.g., mechanical tests, material characterization) to ensure the implant meets established engineering and biocompatibility standards, not an AI algorithm's diagnostic performance.
Here's why the prompt's specific questions cannot be fully answered from this document:
- No AI/Software Component: The Persona Partial Knee is a physical medical device (implant), not a digital health product driven by AI or software.
- Substantial Equivalence: The clearance relies on demonstrating the new "Size B" line extension of the Persona Partial Knee is substantially equivalent to its own previously cleared version (K161592). This typically involves showing that the new size has similar design features, materials, and performance characteristics (e.g., strength, durability, biocompatibility) to the predicate.
- Performance Data Type: The "Performance Data" referenced is non-clinical. For an implant, this would involve mechanical testing (e.g., fatigue testing, wear testing), material characterization, biocompatibility testing, etc., to ensure the device performs as intended and is safe when implanted. It does not involve human readers, expert consensus for ground truth, or analysis of diagnostic accuracy.
Therefore, I cannot provide a table of acceptance criteria or details about a study evaluating AI performance from this document because it is not an AI/software device.
The document does state in the "Summary of Performance Data" section:
"The performance data provided in the performance testing section indicate the proposed devices meet the established acceptance criterion; therefore, are as safe and effective and substantially equivalent to the legally marketed predicate devices from a performance standpoint."
However, it does not detail what those acceptance criteria are or how the performance data was generated beyond stating it was "performance testing." For an implant, these acceptance criteria are typically engineering specifications (e.g., minimum load bearing capacity, maximum wear rate, specific material properties) derived from recognized standards (e.g., ISO, ASTM).
Ask a specific question about this device
(58 days)
MOTO Medial, MOTO Lateral and MOTO Sphere Partial Knee System is designed for cemented use in partial knee arthroplasty, if there is evidence of sufficient sound bone to seat and support the components. Partial replacement of the articulating surfaces of the knee is indicated when only one compartment of the joint is affected due to the compartmental primary degenerative or post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity or revision of previous arthroplasty.
The MOTO Partial Knee System Extension is a Medacta partial knee prosthesis portfolio extension including implantable devices, provided individually packed, sterile and single-use. Specifically, the purpose of this submission is to gain the clearance for: MOTO Sphere femoral components, made of Co-Cr-Mo according to ISO 5832-4 and available in 5 sizes with or without TiNbN coating. They are intended to replace the medial or lateral femoral compartment of the natural knee joint and must be implanted in combination with the tibial component of MOTO Medial or MOTO Lateral (K162084, K183029 and K213071); 7mm thick MOTO Medial and MOTO Lateral inserts fixed made of E-cross, available in 8 sizes and intended to be coupled with the subject MOTO Sphere femoral components as well as MOTO Medial or MOTO Lateral tibial components (K162084, K183029 and K213071).
The provided document is a 510(k) Clearance Letter from the FDA for the MOTO Partial Knee System Extension. This document grants clearance for a medical device (knee implant components) and describes its intended use and comparison to predicate devices, but it does not contain the detailed acceptance criteria and study results you are asking for regarding a software or AI-based device.
The prompt specifically asks for details about a study that proves the device meets acceptance criteria, including information on "human readers improve with AI vs without AI assistance," "standalone (i.e. algorithm only without human-in-the-loop performance)", "ground truth," "training set," etc. These are all concepts related to the validation of Artificial Intelligence (AI) / Machine Learning (ML) enabled software as a medical device (SaMD), often used in diagnostics or image analysis.
The MOTO Partial Knee System Extension is an implantable medical device (hardware). The document explicitly states:
- "No clinical studies were conducted." This is a key indicator that a comparative effectiveness study involving human readers or standalone algorithm performance was not performed or required for this type of device clearance.
- The "Performance Data" section lists "Non-Clinical Studies" focusing on mechanical properties and biocompatibility (e.g., fatigue endurance, contact pressures, wear behavior, pyrogenicity, shelf-life). These are standard tests for orthopedic implants, not AI/ML software.
Therefore, because the provided text is for a hardware implant and not an AI/ML software device, I cannot extract the detailed acceptance criteria and study information related to AI/ML performance from this document.
To answer your request, I would need a 510(k) clearance letter or summary for an AI/ML-enabled medical device.
If you were to provide a document for an AI/ML device, the table and information would be structured as follows (but cannot be populated from the current input):
Acceptance Criteria and Study Proof for an AI/ML Device (Hypothetical, based on expected content)
Since the provided document is for a hardware implant (MOTO Partial Knee System Extension) and not an AI/ML-enabled software device, it does not contain the specific performance evaluation metrics, study designs (e.g., MRMC, standalone), or ground truth establishment methods typically associated with AI/ML device validation.
If this were an AI/ML device, the information requested would be typically found in a "Performance Data" or "Clinical Performance" section of the 510(k) Summary, detailing studies conducted to demonstrate the algorithm's accuracy, sensitivity, specificity, or impact on human reader performance.
1. Table of Acceptance Criteria and Reported Device Performance (Hypothetical Example)
| Acceptance Criteria (e.g., for AI-assisted image analysis) | Reported Device Performance |
|---|---|
| Standalone Performance: | |
| Sensitivity for Condition A: ≥ 90% | 92.5% |
| Specificity for Condition A: ≥ 85% | 88.0% |
| AUC for detecting Condition B: ≥ 0.90 | 0.93 |
| Human-in-the-Loop Performance (MRMC): | |
| Improvement in Reader ROC AUC with AI vs. without AI: statistically significant (p<0.05) | p < 0.001 (significant improvement) |
| Non-inferiority to expert readers for critical findings | Demonstrated non-inferiority |
| Reduction in reading time (e.g., for negative cases) | 20% reduction for negative cases |
2. Sample Size Used for the Test Set and Data Provenance
- Test Set Sample Size: [Specific Number, e.g., 500 cases]
- Data Provenance: [e.g., Retrospective, multi-center, US, Europe, Asia]
3. Number of Experts and Qualifications for Ground Truth
- Number of Experts: [e.g., 3-5]
- Qualifications of Experts: [e.g., Board-certified Radiologists with 10+ years of experience in [specific modality/disease area], Subspecialty-trained Pathologists]
4. Adjudication Method for the Test Set
- Method: [e.g., 2-out-of-3 consensus, if disagreement then 3rd/4th expert arbitrates, independent review by a consensus panel]
5. Multi Reader Multi Case (MRMC) Comparative Effectiveness Study
- Was it done? [Yes/No]
- Effect Size of Human Reader Improvement with AI vs. without AI Assistance: [e.g., "The mean ROC AUC for readers significantly increased from 0.85 (without AI) to 0.91 (with AI assistance), representing an average improvement of 0.06 AUC points (p < 0.001). This translated to a 15% reduction in false negatives."]
6. Standalone (Algorithm Only) Performance Study
- Was it done? [Yes/No]
- Performance Metrics: [e.g., Sensitivity, Specificity, AUC, F1-score, Precision, Recall, Accuracy, etc., with specific values as per the table above]
7. Type of Ground Truth Used
- Type of Ground Truth: [e.g., Expert consensus (as described in #3), Histopathology/Pathology confirmation, Clinical outcomes data, Follow-up imaging]
8. Sample Size for the Training Set
- Training Set Sample Size: [e.g., 10,000 cases]
9. How the Ground Truth for the Training Set was Established
- Method: [e.g., Manual annotation by a team of trained technicians overseen by expert clinicians, Automated labeling from electronic health records, Initial review by a single expert with subsequent confirmation of a subset]
Ask a specific question about this device
(50 days)
The iBalance UKA System is indicated for use in unicompartmental knee arthroplasty as a result of:
- Moderately disabling joint disease of the knee resulting from painful osteoarthritis or post traumatic arthritis;
- Correction of functional deformities;
- Revision of previous unsuccessful unicompartmental knee replacement or other procedure;
- As an alternative to tibial osteotomy in patients with unicompartmental osteoarthritis.
These components are single use only and are intended for implantation with bone cement.
The iBalance PFJ System is indicated for use in patellofemoral joint, (PFJ) knee arthroplasty as a result of:
- Degenerative arthritis in the distal femur and patella;
- A history of patellar dislocation or fracture;
- Failed previous surgery (arthroscopy, tibial tubercle elevation, lateral release) where pain, deformity or dysfunction persists.
These components are single use only and are intended for implantation with bone cement.
When used concurrently, the Arthrex iBalance UKA and PFJ systems create the Arthrex iBalance BiCompartmental Arthroplasty System. The Arthrex iBalance BiCompartmental Arthroplasty System is intended to be used as a multicompartmental knee arthroplasty in patients with:
- Moderately disabling joint disease of the knee resulting from painful osteoarthritis or post traumatic arthritis;
- Correction of functional deformities;
- Revision of previous unsuccessful partial knee replacement or other procedure.
The iBalance BiCompartmental Arthroplasty System is not intended to be used as a dual-condyle or tri-compartmental knee.
These components are single use only and are intended for implantation with bone cement.
The Arthrex iBalance Partial Knee System encompass the following FDA cleared devices:
- Arthrex iBalance UKA System
- Arthrex iBalance PFJ System
- Arthrex iBalance BiCompartmental Arthroplasty System
These systems are comprised of femoral, tibia and patellar components for use in knee prosthesis.
The provided FDA 510(k) clearance letter for the Arthrex iBalance Partial Knee System does not contain the information requested regarding acceptance criteria and the study proving the device meets those criteria, particularly in the context of an AI/algorithm-based medical device.
This document is a clearance letter for a physical medical device (a knee replacement system), not an AI-powered diagnostic or treatment algorithm. The "performance data" mentioned refers to non-clinical and in-vivo electromagnetic simulation related to the device's "MR Conditional" status, which is about its safety in an MRI environment, not its diagnostic or therapeutic accuracy as an AI would have.
Therefore, I cannot extract the requested information (such as sample sizes for test/training sets, expert consensus, MRMC studies, etc.) from this document because it is not relevant to an AI/algorithm-based device study.
To provide the information you're looking for, I would need a 510(k) clearance letter or a clinical study report specifically detailing the performance evaluation of an AI/algorithm-based medical device.
Ask a specific question about this device
(214 days)
The ACTIFY™ Unicondylar Knee System is indicated for unicompartmental knee replacement due to the following conditions:
- Moderately disabling joint disease of the knee resulting from painful osteo- and/or post-traumatic arthritis, or avascular necrosis.
- Revision of previous unsuccessful unicompartmental knee replacement or other procedure.
- Alternative to tibial osteotomy in patients with unicompartmental osteoarthritis.
- Previous tibial condyle or plateau fractures with loss of anatomy or function.
- Varus or valgus deformities.
These devices are indicated for cemented use only.
The ACTIFY™ Unicondylar Knee System implants consist of femoral and tibial implants that are used as part of a unicompartmental knee system for partial knee arthroplasty. Implants are available in various configurations and sizes to fit a wide variety of patient anatomy. ACTIFY Unicondylar femoral implants are manufactured from cobalt chrome alloy, tibial inserts are manufactured from ultra high molecular weight polyethylene (UHMWPE) with and without Vitamin E, and tibia trays are manufactured from titanium alloy.
I am sorry, but the provided text is a 510(k) premarket notification for a medical device (ACTIFY™ Unicondylar Knee System) and does not contain information about acceptance criteria, device performance, sample size, ground truth establishment, or expert qualifications for a study proving the device meets acceptance criteria.
The document discusses:
- The FDA's decision of substantial equivalence to predicate devices.
- The indications for use of the device.
- The materials and components of the device.
- A list of performance tests conducted (fatigue, wear, interlocking strength, etc.) according to various ASTM and ISO standards.
- A general statement that "Performance data demonstrate substantial equivalence to the predicate devices."
It does not provide:
- A table of acceptance criteria and reported device performance.
- Sample sizes or data provenance for any clinical or large-scale performance study.
- Information on experts, adjudication methods, or ground truth for a test set.
- Details on MRMC studies or AI assistance.
- Information about standalone algorithm performance.
- Sample sizes or ground truth establishment for a training set.
Therefore, I cannot fulfill your request based on the provided text.
Ask a specific question about this device
(51 days)
Unicompartmental knee implants are indicated for restoring either compartment of a knee that has been affected by the following:
· Noninflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, or avascular necrosis; and · Partial revisions to replace the tibial insert of the previously implanted JOURNEY II UK knee in the femoral and tibial components are well-fixed.
Unicompartmental knee implants are single use only and are intended for implantation only with bone cement.
The JOURNEY II Unicompartmental Knee System includes femoral components, tibial inserts that restore either compartment of the knee (K190085, K230653). JOURNEY II UK provides joint replacement on a single condylar compartment, meaning that only one condyle will be replaced instead of the entire femoral component replaces the damaged condylar component of the femur. The tibial baseplate replaced the damaged part of the tibial insert is the articulating surface which allows the knee to bend and flex smoothly and is placed above the tibial baseplate.
The Smith & Nephew JOURNEY II Unicompartmental Knee System consists of OXINUM femoral components, titanium tibial baseplates, and cross-linked polyethylene (XLPE) tibial inserts.
The provided text is a 510(k) summary for the JOURNEY II Unicompartmental Knee System. It focuses on labeling updates and explicitly states that there are no changes to the design features, materials, or manufacturing methods of the device.
Therefore, the document does not contain any information regarding acceptance criteria or a study that proves the device meets acceptance criteria for performance in the typical sense of a new or significantly modified medical device that would require such studies. It explicitly states:
"Therefore, since there are no changes to the design features, materials, or manufacturing methods of the subject I I Unicompartmental Knee System devices, no performance testing (bench, animal, clinical) was required." and "Not Applicable." and "No modifications are being introduced to the subject devices as a result of this filing."
Hence, I cannot provide the requested information from this document. The submission is a request for clearance for labeling updates only, not for a new or modified device requiring new performance studies.
Ask a specific question about this device
(26 days)
The OvertureTi Knee Resurfacing System"is intended to be used in the partial replacement of the articulating surfaces of the knee in instances where, due to compartmental degenerative disease, post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity, or previous arthroplasty, only the one side of the joint is affected. This device is intended to be used with bone cement.
The OvertureTi Knee Resurfacing System™ is comprised of femoral implants, and a set of ancillary instruments. The femoral implants are titanium and feature a spherical polished articulating surface with a titanium nitride (TiN) coating. The tibial implants are comprised of a titanium tibial tray with an integrated ultra-high molecular weight polyethylene (UHMWPE) tibial insert. The UHMVPE has Vitamin-E infused (0.1% by weight). The femoral implants and tibial trays utilize cemented pegs and porous titanium bone-contacting surfaces to allow for fixation. The femoral implant articulates against the tibial insert in a non-constrained manner.
The implants are provided in a variety of configurations and sizes to accommodate various patient anatomy. Femoral implants are offered in oblong and round configurations. The oblong femoral implants are offered in lengths ranging 25-40mm and diameters ranging 17.5-27.5mm, and the round femoral implants are offered in diameters ranging 17.5-27.5mm. The tibial implants are offered in diameters ranging 17.5-22.5mm. The implants are provided gamma sterilized and individually packaged.
The provided text is a 510(k) Premarket Notification from the FDA for the "OvertureTi Knee Resurfacing System™." This document is a regulatory approval letter and does not contain information about a study proving the device meets acceptance criteria related to AI/ML or diagnostic performance. Instead, it focuses on the device's substantial equivalence to a predicate device for its intended use as a knee resurfacing system.
Therefore, I cannot extract the requested information about acceptance criteria for device performance in the context of an AI/ML study, nor details about sample sizes, expert involvement, or MRMC studies, as these elements are not present in this type of submission.
The "Testing" section mentions:
- "Vitamin-E UHMWPE Rationale"
- "Characterization of Vit-E UHMWPE"
- "Vitamin-E Tibial Alignment Feature Test Report"
These are related to material characterization and mechanical/design features of the implant, not to diagnostic or AI/ML performance. The conclusion states that "rationales and testing... indicated no new risks and demonstrated substantial equivalence in performance compared to a legally marketed predicate." This refers to the mechanical and biological safety of the implant itself, not its diagnostic accuracy or AI assistance.
Ask a specific question about this device
(265 days)
The Kyocera TRIBRID® Unicompartmental Knee System is indicated for use in patients with the following:
- Painful and disabled knee joint resulting from osteoarthritis, or idiopathic osteonecrosis, of . either the medial or lateral compartments.
- Correction of varus, valgus, or posttraumatic deformity. .
- As an alternative to tibial osteotomy in patients with unicompartmental NIDJD disease. .
- Revision procedures where other treatments or devices have failed. ●
This device is intended for cemented use only.
KMTI's TRIBRID® Unicompartmental Knee System is a partial knee replacement prostheses intended for application with bone cement. Partial knee replacement components include femoral and tibial components. Femoral baseplates are CoCrMo Alloy while the Tibial implants are Ti6Al4V Alloy. The Tibial bearing inserts are made from Ultra-High Molecular Weight Polyethylene (UHMWPE) variations. Components are available in a variety of designs and size ranges intended for both primary and revision applications.
This document is a 510(k) summary for the Kyocera TRIBRID® Unicompartmental Knee System, a medical device. It focuses on mechanical, non-clinical performance data rather than AI/software performance. Therefore, many of the requested criteria related to AI device performance are not applicable.
Here's an analysis based on the provided document:
Acceptance Criteria and Reported Device Performance
The acceptance criteria for this device are based on demonstrating that its mechanical performance is sufficient for its intended use and is substantially equivalent to legally marketed predicate devices. The document does not provide specific quantitative pass/fail values as acceptance criteria; rather, it lists the types of tests performed and concludes that the results support substantial equivalence.
Table of Acceptance Criteria and Reported Device Performance:
| Acceptance Criteria Category (Implicit from tests) | Reported Device Performance (Summary) |
|---|---|
| Mechanical Strength & Durability | |
| Baseplate Fatigue (per ASTM F3140-17) | Results show sufficient strength for intended use. |
| Femoral Component Durability (per ASTM F3210-22) | Results show sufficient strength for intended use. |
| Intrinsic Stability Characteristics | Not specified quantitatively, but contributes to overall conclusion of substantial equivalence. |
| Modular Disassembly Characteristics (per ASTM F1814 and ASTM F2083) | Not specified quantitatively, but contributes to overall conclusion of substantial equivalence. |
| Range of Motion Assessment (per ASTM F2083) | Not specified quantitatively, but contributes to overall conclusion of substantial equivalence. |
| Simulated Wear (per ISO 14243-3) | Not specified quantitatively, but contributes to overall conclusion of substantial equivalence. |
| Overall Comparison to Predicate Devices | The overall technology characteristics and mechanical performance data lead to the conclusion that the TRIBRID® Unicompartmental Knee System is substantially equivalent to the predicate device. |
Study Details (based on the provided document)
Since the document describes a mechanical device and its non-clinical performance testing rather than an AI/software device, many of the typical questions for AI acceptance criteria and studies (e.g., sample size for test set, data provenance, number of experts, MRMC studies, standalone performance) are not applicable.
-
Sample size used for the test set and the data provenance:
- Sample Size: Not explicitly stated in this summary. Mechanical tests typically use a small number of samples (e.g., 3-6 or more, depending on the standard) to demonstrate compliance with a standard or to compare to predicate devices.
- Data Provenance: Not applicable. This is in vitro mechanical testing, not human data.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not applicable. Ground truth for mechanical testing is established by engineering specifications, material properties, and industry standards (e.g., ASTM, ISO), not by expert consensus on clinical data.
-
Adjudication method (e.g., 2+1, 3+1, none) for the test set:
- Not applicable. This is for mechanical testing, not interpretation of clinical imagery or data by experts. Test results are typically compared directly to standard requirements or predicate device performance.
-
If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- Not applicable. This is a knee implant, not an AI-powered diagnostic or assistive tool.
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- Not applicable. This is a physical medical device, not an algorithm.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.):
- Mechanical Testing Standards: The "ground truth" for this type of device is compliance with industrial standards (e.g., ASTM, ISO) for mechanical properties, durability, and wear, and demonstrating substantial equivalence to predicate devices that have established safety and effectiveness through their historical use.
-
The sample size for the training set:
- Not applicable. This is non-clinical mechanical testing, not a machine learning model.
-
How the ground truth for the training set was established:
- Not applicable. As above, this is mechanical engineering testing.
Ask a specific question about this device
(310 days)
The Overture Resurfacing Uni Knee Resurfacing System is intended to be used in the partial replacement of the articulating surfaces of the knee in instances where, due to compartmental degenerative disease, post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity, or previous arthroplasty, only the one side of the joint is affected. This device is intended to be used with bone cement.
The Uni Knee Resurfacing System is comprised of femoral implants, and a set of ancillary instruments. The femoral implants are titanium and feature a spherical polished articulating surface with a titanium nitride (TIN) coating. The tibial implants are comprised of a titanium tibial tray with an integrated ultra-high molecular weight polyethylene (UHMWPE) tibial insert. The femoral implants and tibial trays utilize cemented pegs and porous titanium bone-contacting surfaces to allow for fixation. The femoral implant articulates against the tibial insert in a non-constrained manner.
The implants are provided in a variety of configurations and sizes to accommodate various patient anatomy. Femoral implants are offered in oblong and round configurations. The oblong femoral implants are offered in lengths ranging 25-40mm and diameters ranging 17.5-27.5mm, and the round femoral implants are offered in diameters ranging 17.5-27.5mm. The tibial implants are offered in diameters ranging 17.5-22.5mm.
The implants are provided gamma sterilized and individually packaged. The ancillary instruments are provided non-sterile and are to be sterilized by the end user.
This document is a 510(k) summary for the Uni Knee Resurfacing System. It focuses on demonstrating substantial equivalence to a predicate device based on design, materials, and performance testing, rather than an AI/ML-based device requiring extensive clinical study for performance metrics like accuracy, sensitivity, or specificity.
Therefore, the requested information regarding acceptance criteria and a study proving the device meets these criteria in the context of AI/ML performance (e.g., sample size, data provenance, expert ground truth, MRMC studies) is not applicable to this submission.
The "Performance Testing" section (page 4) details bench testing conducted for the Uni Knee Resurfacing System, which typically involves mechanical and material evaluations, not clinical performance metrics for an AI algorithm.
To specifically address the prompts:
-
A table of acceptance criteria and the reported device performance: Not applicable. The document describes engineering and material-based performance tests, not AI-related performance metrics. The conclusion states that these tests "indicated no new risks and demonstrated substantial equivalence in performance compared to a legally marketed predicate." Specific numerical acceptance criteria for each bench test are not provided in this summary.
-
Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective): Not applicable. This document refers to bench testing of physical implants, not an AI algorithm's performance on clinical data.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience): Not applicable. Ground truth as typically defined for AI validation (e.g., expert consensus on medical images) is not relevant to this device's testing.
-
Adjudication method (e.g. 2+1, 3+1, none) for the test set: Not applicable.
-
If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance: Not applicable. This is not an AI-assisted device.
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done: Not applicable.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc.): Not applicable in the context of AI. The "ground truth" for the performance testing would be established by objective measurements and scientific standards for material properties, mechanical strength, wear, etc., as per the listed ASTM and other relevant engineering standards.
-
The sample size for the training set: Not applicable. There is no AI algorithm being trained.
-
How the ground truth for the training set was established: Not applicable.
Ask a specific question about this device
(280 days)
The Signature Orthopaedics' TLC Unicompartmental Knee comprising the femur component, tibial component and meniscal inserts is designed for a single compartment of the natural knee joint. The TLC Unicompartmental Knee is indicated for cemented use in partial knee arthroplasty procedures. Partial replacement of the articulating surfaces of the knee is indicated only when only one compartment of the joint is affected due to the compartmental primary degenerative or post-traumatic degenerative disease, previous tibial condyle or plateau fractures, deformity or revision of previous arthroplasty.
The TLC Unicompartmental Knee system is a modular knee system consisting of a femoral component, meniscal insert and a tibial baseplate. The femoral component is manufactured from cast cobalt chromium alloy and are intended for use with bone cement. The tibial baseplate component is manufactured from titanium alloy and intended for use with bone cement. The meniscal insert is manufactured from UHMWPE.
This document is an FDA 510(k) clearance letter for a medical device (TLC Unicompartmental Knee System). It grants the manufacturer permission to market the device based on its substantial equivalence to previously cleared predicate devices.
Crucially, this document does not contain information about acceptance criteria or a study proving the device meets those criteria (e.g., performance metrics, sample sizes, ground truth establishment, or multi-reader studies).
The "Performance Testing" section lists the types of non-clinical tests performed (e.g., Range of motion analysis, Tibial plate fatigue testing), but it does not provide any specific acceptance criteria or the results of these tests. It merely states that "Non-clinical testing and engineering evaluations were conducted to verify that the performance of the TLC UniKnee system is adequate for anticipated in-vivo use."
Therefore, I cannot extract the information required to populate the requested table and answer the questions directly from the provided text. The document focuses on regulatory clearance based on substantial equivalence, not on a detailed clinical or performance study demonstrating specific achievement of acceptance criteria.
Ask a specific question about this device
Page 1 of 8