510(k) Data Aggregation

    K Number
    K980638

    Validate with FDA (Live)

    Date Cleared
    1998-07-06

    (137 days)

    Product Code
    Regulation Number
    866.3820
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Ampcor RPR control kit is designed as an unassayed control material to monitor the precision of AMPCOR RPR (Carbon-Particle) Liquid Reagent or other RPR tests at three reaction levels.

    Device Description

    Not Found

    AI/ML Overview

    The provided text is a 510(k) clearance letter from the FDA for a device called "ADI Syphilis RPR Liquid Controls." This letter grants clearance based on substantial equivalence to a predicate device, which is different from a study proving a device meets acceptance criteria.

    The document does not contain any information about:

    • Acceptance criteria table or reported device performance for a study.
    • Sample sizes for test or training sets, data provenance, or ground truth establishment.
    • Number or qualifications of experts.
    • Adjudication methods.
    • Multi-reader multi-case (MRMC) comparative effectiveness studies or standalone algorithm performance.

    The document's purpose is to inform Ampcor Diagnostics, Inc. that their device is substantially equivalent to a previously marketed device and can therefore be marketed. It refers to general controls provisions of the Act and compliance with Good Manufacturing Practice requirements, but it does not detail a specific performance study or its results for the ADI Syphilis RPR Liquid Controls device itself.

    Ask a Question

    Ask a specific question about this device

    K Number
    K961998

    Validate with FDA (Live)

    Date Cleared
    1996-08-08

    (78 days)

    Product Code
    Regulation Number
    866.3820
    Age Range
    N/A
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use
    Device Description
    AI/ML Overview
    Ask a Question

    Ask a specific question about this device

    K Number
    K955143

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    1996-07-30

    (260 days)

    Product Code
    Regulation Number
    866.3820
    Age Range
    All
    Reference & Predicate Devices
    N/A
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Reasonable assurance that this device is safe and effective was determined through the use of valid scientific nonclinical investigations including in vitro studies. The results of these studies are summarized in the attached Technical Insert. This device is effective when tested under the conditions for its Each test kit contains a technical insert which intended use.

    Device Description

    Not Found

    AI/ML Overview

    Acceptance Criteria and Device Performance for RPR Liquid Controls

    This submission pertains to the RPR Liquid Controls device for which "reasonable assurance that this device is safe and effective was determined through the use of valid scientific nonclinical investigations including in vitro studies." The submission indicates that "relative sensitivity and specificity data" are provided within the accompanying technical insert, but the specific acceptance criteria and detailed performance metrics are not explicitly stated in the provided text.

    Based on the provided data tables, the study appears to be a comparative study of the REMEL RPR CARD TEST CONTROLS against Reference Positive and Negative Controls. The performance is assessed by comparing the qualitative results (Reactive-R/moderately Reactive-Rmod/Non-Reactive-N or NR) of the REMEL controls against the established Reference controls.

    1. Table of Acceptance Criteria and Reported Device Performance

    Note: The acceptance criteria are inferred from the study design where the REMEL controls are expected to match the Reference controls. The provided data demonstrates this matching.

    Acceptance Criterion (Inferred)Reported Device Performance (Summary from data tables)
    Positive Control Performance: REMEL Positive Control (RPR CARD TEST CONTROLS) should consistently show a "Reactive" (R) or "Moderately Reactive" (Rmod/mR/me) result.At both testing sites (Michigan Department of Public Health and UTex), the REMEL Positive Control consistently showed a "Reactive" (R) or "Moderately Reactive" (Rmod, mR, me, R4+) result, matching the Reference Positive Control.
    Negative Control Performance: REMEL Negative Control (RPR CARD TEST CONTROLS) should consistently show a "Non-Reactive" (N or NR) result.At both testing sites, the REMEL Negative Control consistently showed a "Non-Reactive" (N or NR) result, matching the Reference Negative Control.
    Agreement with Reference Controls: REMEL Positive and Negative Controls should consistently provide results that match the corresponding Reference Positive and Negative Controls.100% agreement between the REMEL RPR CARD TEST CONTROLS and the Reference Controls for both positive and negative controls across all recorded dates and testing sites.

    2. Sample Size Used for the Test Set and Data Provenance

    • Sample Size for Test Set:
      • Michigan Dept. of Public Health Site: The data table shows recorded results for 23 distinct dates for both positive and negative controls. Each date represents a test run.
      • UTex Site: The data table shows recorded results for 15 distinct dates for both positive and negative controls. Each date represents a test run.
      • Total Test Observations: 38 test observations (dates) across two sites for both positive and negative controls.
    • Data Provenance: The data comes from two distinct sites:
      1. Michigan Dept. of Public Health, with H. Stiefel as the Principal Investigator (PI).
      2. UTex, with Hartwell as the Principal Investigator (PI).
        The data appears to be prospective, as it's dated chronologically from July/August 1995 to October 1995, indicating ongoing testing of the controls.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Qualifications

    The provided document does not mention the use of experts or their qualifications for establishing ground truth for this particular study. This study is for RPR Liquid Controls, which are themselves reference materials used to validate the performance of an RPR CARD TEST. The "Reference Pos Crtl" and "Reference Neg Crtl" serve as the ground truth in this context, representing established standards for positive and negative reactivity.

    4. Adjudication Method for the Test Set

    The document does not describe any specific adjudication method (e.g., 2+1, 3+1). Since the comparison is between a test control and a reference control, the result is likely a direct match/non-match rather than requiring expert consensus for interpretation.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not performed. This study evaluates the performance of laboratory controls, not the interpretation by human readers, and therefore, the concept of "human readers improving with AI vs. without AI assistance" is not applicable here.

    6. Standalone Performance (Algorithm Only)

    This device (RPR Liquid Controls) is a laboratory control material, not an algorithm or an AI-powered device. Therefore, a standalone (algorithm only) performance assessment, as typically understood for AI, is not applicable. The data presented shows the performance of the liquid controls themselves when used in a standard RPR card test.

    7. Type of Ground Truth Used

    The ground truth used in this study is based on established "Reference Positive Controls" and "Reference Negative Controls." These are presumably well-characterized and validated materials that are known to elicit a specific (positive or negative) reaction in the RPR test. This is a form of reference standard (or gold standard) truth based on known characteristics of the samples.

    8. Sample Size for the Training Set

    The document does not mention any training set. This is expected as the RPR Liquid Controls are a reagent/control product, not a machine learning model that requires training. The data presented is for validation/verification of the control's performance.

    9. How the Ground Truth for the Training Set Was Established

    As there is no training set for this product, this question is not applicable.