HORIZON AF Plus is intended for use in adult and small adult surgical procedures requiring cardiopulmonary bypass. It provides gas exchange support and blood temperature control. HORIZON AF Plus integrated arterial filter provides additional protection against air and solid emboli.
HORIZON AF Plus is intended to be used for 6 hours or less.
The HORIZON AF PLUS System (Model number: US5300) is composed of the HORIZON ADULT OXYGENATOR with Integrated Arterial Filter Plus (A.L. One AF Plus) and the Horizon cardiotomy/venous reservoir (CVR).
The HORIZON ADULT OXYGENATOR with Integrated Arterial Filter Plus is a microporous hollow-fibre membrane oxygenator consisting of a gas exchange module with an integrated heat exchanger and an integrated 38μm arterial filter that ensures arterial blood filtration with removal of microaggregates and microemboli.
HORIZON AF PLUS also has a hard-shell cardiotomy/venous reservoir (CVR) integrated with two cardiotomy filters, designed to allow venous drainage of the patient's blood, both through the hydrostatic load (height difference between the patient and the reservoir) and the vacuum-assisted venous drainage (VAVD) technique.
HORIZON AF PLUS inner contact surfaces are coated with A.G.I.L.E. (Advanced Generation Inert Layer E.C.C.) system, based on Phosphorylcoline (PC).
The device is single use, non-pyrogenic, supplied STERILE and individually packed.
The device is individually packed and sterilized by ethylene oxide.
N/A
Ask a specific question about this device
(459 days)
The Trilly Oxygenator with Integrated Arterial Filter and Hardshell Reservoir is intended to be used to exchange gases between blood and a gaseous environment to satisfy the gas exchange needs of a patient during cardiopulmonary bypass surgery.
The integrated arterial filter is intended to filtrate non-biologic particles and emboli and to facilitate air bubble removal from the blood flowing through the cardiopulmonary bypass circuit. The integrated heat exchanger is used to warm or cool blood and/or perfusion fluid as it flows through the device.
The hardshell reservoir is used to store blood during extra-corporeal circulation from the venous line and the cardiotomy line. The reservoir contains a venous section that is compromised of a filter and defoamer to facilitate air bubble removal. The cardiotomy section of the reservoir contains a filter to remove particulate matter and a defoamer to facilitate air bubble removal. The 2.5-liter reservoirs may be used for Vacuum Assisted Drainage procedures and Post-Operative Chest Drainage Procedures.
Trilly Oxygenator with Integrated Arterial Filter and Hardshell Reservoir is for use with patients when the required blood flow will not exceed 3.5 L/min and within a BSA range of 1.28 to 1.46.
Trilly Oxygenator with Integrated Arterial Filter and Hardshell Reservoir can be used in procedures lasting up to 6 hours.
The TRILLY OXYGENATOR with Integrated Arterial Filter and Hardshell Reservoir ("Trilly AF") is a microporous hollow-fibre membrane oxygenator consisting of a gas exchange module with an integrated heat exchanger and an integrated 38μm arterial filter that ensures arterial blood filtration and facilitates air removal from emboli.
The device also has a hard-shell cardiotomy/venous reservoir (CVR) that can be connected to the aspirators, designed to allow venous drainage of the patient's blood, making it both the hydrostatic load offered by the difference in height between the patient and the reservoir and the vacuum-assisted technique (VAVD).
The device hard-shell cardiotomy/venous reservoir is fitted with a pressure relief valve.
The device inner contact surfaces are coated with A.G.I.L.E. (Advanced Generation Inert Layer E.C.C.) system, based on Phosphorylcholine (PC). The A.G.I.L.E. coating doesn't have any biological activity.
The device is single use, non-pyrogenic, supplied sterile and individually packed. It is sterilized by ethylene oxide.
N/A
Ask a specific question about this device
(435 days)
VT75-E1
Quantum Perfusion Blood Oxygenator is a diffusion membrane oxygenator, designed to oxygenate and remove carbon dioxide from venous blood during cardiac surgery requiring cardiopulmonary bypass and to measure blood pressure and temperature during the procedure. The device is limited to 6 hours of use.
Device is intended for Paediatric patients with a Body Surface Area (BSA) ranging from 0.6 m² to 1 m².
VT75-E2
Quantum Perfusion Blood Oxygenator is a diffusion membrane oxygenator, designed to oxygenate and remove carbon dioxide from venous blood during cardiac surgery requiring cardiopulmonary bypass and to measure blood pressure during the procedure. The device is limited to 6 hours of use.
Device is intended for Paediatric patients with a Body Surface Area (BSA) ranging from 0.6 m² to 1 m².
The Quantum Perfusion Blood Oxygenator (acronym VT-E) diffusion membrane device is designed to oxygenate blood and remove carbon dioxide from venous blood during cardiac surgical procedures requiring cardiopulmonary bypass for a maximum duration of 6 hours.
Blood enters the oxygenator through the blood inlet connector, flows through a blood chamber, touching the outer surface of hollow fibers membrane; while the sweep gas flows into the hollow fiber membrane. The hollow fibers are made of Polymethylpentene (PMP). In this chamber, carbon dioxide moves from the blood to the gas compartment, while oxygen enters into the red blood cells. Then, blood exits the oxygenator with the desired level of oxygen content and saturation, and carbon dioxide content. Sweep gas composition and flow rate are used to control saturation, and oxygen and carbon dioxide content of blood at the outlet of the oxygenator. The device is non-toxic, non-pyrogenic, sterilized by ethylene oxide and packaged in a single box.
All the device surfaces in contact with blood are treated with a phosphorylcholine-based biocompatible coating.
The provided document, K231982, is a 510(k) Premarket Notification for a medical device (Quantum Perfusion Blood Oxygenator VT75-E1, Quantum Perfusion Blood Oxygenator VT75-E2). This document details the device's technical specifications, intended use, and comparison to predicate devices, along with performance data regarding non-clinical testing.
However, it does not describe acceptance criteria, nor a study that proves the device meets specific acceptance criteria in the context of an AI/ML medical device. The document explicitly states:
- "No clinical data have been included in the current Traditional 510(k) submission to support substantial equivalence to legally marketed predicate devices."
- "No animal studies have been performed except for mandatory biocompatibility tests according to International Standard ISO 10993-1:2018".
The performance data mentioned (Gas transfer performance, Temperature probe and Pressure sensor verification, Mechanical Blood Cell Damage, Device pressure Drop, Mechanical Integrity, Mechanical resistance of connectors, Coating coverage and durability, Air handling) are engineering and functional tests relevant to a blood oxygenator, not the kind of AI/ML performance metrics typically found in documents describing acceptance criteria for an AI-powered diagnostic or assistive device.
Therefore, I cannot provide the requested information regarding acceptance criteria and a study proving the device meets them, as it pertains to an AI/ML device, because this document is for a non-AI/ML medical device and does not contain such information.
Ask a specific question about this device
(124 days)
Model BB811 and Model BB811-NS: The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration. The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is designed to filter from the circuit microemboli larger than the specified micron size for periods up to six hours during cardiopulmonary bypass surgery.
Model BB841: Oxygenator with Integrated Arterial Filter: The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration. The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface is designed to filter from the circuit microemboli larger than the specified micron size for periods up to six hours during cardiopulmonary bypass surgery. Cardiotomy/Venous Reservoir: The Affinity Fusion Cardiotomy/Venous Reservoir with Balance Biosurface is intended to be used in an extracorporeal perfusion circuit to collect venous and cardiotomy suctioned blood during routine cardiopulmonary procedures up to 6 hours in duration. The CVR is also intended for use during vacuum assisted venous drainage (VAVD) procedures. The Affinity Fusion Cardiotomy/Venous Reservoir with Balance Biosurface is also intended for use after open heart surgery to collect autologous blood from the chest and to aseptically return the blood to the patient for blood volume replacement.
The Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (BB811), Affinity Fusion Oxygenator with Integrated Arterial Filter and Cardiotomy/Venous Reservoir with Balance Biosurface (BB841), and Affinity Fusion Oxygenator with Integrated Arterial Filter and Balance Biosurface (Non-Sterile) (B811-NS) are collectively referred to as the Affinity Fusion Oxygenator in the summary. The Affinity Fusion Oxygenator is intended to be used in an extracorporeal perfusion blood circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration. The Affinity Fusion Oxygenator contains both an integrated arterial filter and integrated heat exchanger. The Affinity Fusion Oxygenator is a microporous, hollow-fiber, gas-exchange devices available with Balance Biosurface bonded to the blood contacting surface of the device. The integrated arterial filter is designed to filter from the circuit microemboli larger than the specified micron size from the circuit for periods up to six hours during cardiopulmonary bypass surgery. Some models of the Affinity Fusion Oxygenator are packaged with an Affinity Fusion Cardiotomy/Venous Reservoir (CVR) with Balance Biosurface which is designed to be an integral part of a cardiopulmonary bypass circuit for use during cardiac surgery. The Affinity Fusion CVR is designed to collect venous and cardiotomy suctioned blood during routine cardiopulmonary procedures up to six (6) hours in duration. Additionally, the Affinity Fusion CVR may be used during vacuum assisted venous drainage (VAVD) procedures and collect autologous blood from the chest and to aseptically return the blood to the patient for blood volume replacement during open heart surgery.
The provided text discusses the Affinity Fusion Oxygenator and its acceptance criteria, specifically focusing on the addition of an alternate hollow fiber supplier.
Here's an analysis of the acceptance criteria and the study that proves the device meets them:
1. A table of acceptance criteria and the reported device performance:
| Test Item | Acceptance Criteria (Implied: PASS) | Reported Device Performance |
|---|---|---|
| O2 Transfer | PASS | PASS |
| CO2 Transfer | PASS | PASS |
| Blood Side Pressure Drop | PASS | PASS |
| 6 Hour O2 Transfer | PASS | PASS |
| 6 Hour CO2 Transfer | PASS | PASS |
| Pressure Integrity | PASS | PASS* |
| Burst | PASS | PASS |
| Gas Pathway Integrity | PASS | PASS |
| Plasma Breakthrough | PASS | PASS |
| Filtration Efficiency | PASS | PASS |
| Hemolysis (Max Flow) | PASS | PASS |
| White Blood Cell Retention | PASS | PASS |
| Platelet (PLT) retention | PASS | PASS |
| Functional platelet retention | PASS | NA (not specified as tested at this time point) |
| Platelet PLT Function (min flow) | PASS | NA (not specified as tested at this time point) |
| Prime Volume | PASS | PASS |
| Coverage | PASS | PASS |
| Leaching | PASS | PASS |
Biocompatibility Testing:
| Biocompatibility Test Method | Testing Category | Reported Device Performance |
|---|---|---|
| ISO MEM Elution Cytotoxicity, L929 Mouse Fibroblast Cells | Cytotoxicity | PASS |
| ISO Maximization Sensitization Study, 0.9%Sodium Chloride & Sesame Oil, NF extract | Sensitization | PASS |
| ISO Intracutaneous Study – 0.9% Sodium Chloride & Sesame Oil, NF extract | Intracutaneous Reactivity | PASS |
| ISO Systemic Toxicity Study - 0.9% Sodium Chloride & Sesame Oil, NF extract | Acute Systemic Toxicity | PASS |
| Pyrogen Study – Material Mediated -0.9%Sodium Chloride | Material Mediated Pyrogen Study | PASS |
| ASTM In-vitro Hemolysis, Rabbit Blood | Hemocompatibility | PASS |
| Complement Activation, SC5b-9, Human Serum | Hemocompatibility | PASS |
| ASTM Partial Thromboplastin Time, Direct Contact, Human Plasma | Hemocompatibility | PASS |
| Genotoxicity, Bacterial Reverse Mutation Study | Genotoxicity | PASS |
| Genotoxicity: Mouse Lymphoma Assay | Genotoxicity | PASS |
| Platelet and Leukocyte Count- with comparison article | Hemocompatibility | PASS |
*Note on "Pressure Integrity": Devices conditioned only to factors significant for leaks (per Two Proportion statistical test).
2. Sample sized used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective):
The document does not explicitly state the sample sizes for the test sets (number of oxygenator units tested) for design verification or biocompatibility. It also does not specify the country of origin of the data or whether the studies were retrospective or prospective. The nature of the tests (engineering performance and biocompatibility) suggests these were primarily laboratory-based prospective tests.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience):
This information is not applicable to the type of device and testing described. The "ground truth" for a medical device like an oxygenator is established through objective performance measurements and standardized biocompatibility tests, not subjective expert assessment as would be the case for image interpretation or diagnosis.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set:
This information is not applicable. Adjudication methods like "2+1" or "3+1" are typically used in clinical studies or studies involving subjective human interpretation (e.g., radiology reads) to resolve discrepancies. The tests described here are objective performance and safety tests.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
This is not applicable. The device is an oxygenator, not an AI-powered diagnostic tool requiring human reader studies.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
This is not applicable. The device is an oxygenator, not an algorithm.
7. The type of ground truth used (expert concensus, pathology, outcomes data, etc):
The ground truth for this device is based on:
- Engineering specifications and standards: For performance characteristics like O2 Transfer, CO2 Transfer, Pressure Drop, Burst, Filtration Efficiency, etc. "PASS" implies meeting predefined, objective measurable criteria.
- International standards for biocompatibility (ISO 10993-1:2018): For tests like cytotoxicity, sensitization, genotoxicity, hemocompatibility, etc. "PASS" means meeting the established safety thresholds for these biological endpoints.
8. The sample size for the training set:
This is not applicable. This is not an AI/machine learning device that requires a training set. The "study" described is a series of laboratory-based design verification and biocompatibility tests.
9. How the ground truth for the training set was established:
This is not applicable, as there is no training set for this type of device.
Ask a specific question about this device
(30 days)
Affinity NT Oxygenator and Uncoated Cardiotomy/ Venous Reservoir (541);
The AFFINITY NT Integrated CVR Membrane Oxygenator with Plasma Resistant Fiber is intended to be used in an extracorporeal perfusion circuit to collect venous and cardiotomy suctioned blood, cool or warm the blood and oxygenate and remove carbon dioxide from the blood during routine cardiopulmonary bypass procedures up to 6 hours in duration.
Indications for Use(541B)
The Affinity NT oxygenator with Balance biosurface is intended to be used in an extracorporeal perfusion circuit to oxygenate and remove carbon dioxide from the blood and to cool or warm the blood during routine cardiopulmonary bypass (CPB) procedures up to 6 hours in duration. The Affinity NT cardiotomy/venous reservoir (CVR) is intended to be used in an extracorporeal perfusion circuit to collect venous and cardiotomy suctioned blood during routine CPB procedures up to 6 hours in duration.
The Affinity NT Oxygenator with /without Balance Biosurface is a sterile membrane Oxygenator with plasma resistant fiber. It is a single-use gas exchange device with integral stainless-steel heat exchanger. Models 541 and 541B include a cardiotomy/venous reservoir.
The Luer cap 1140008-503 that is the 'subject' of this special 510(k) serve as protection of the Luer Access Port. This port can be used to prime the circuit or connect to another support device with a luer connector.
This is a 510(k) summary for a medical device change, not a study proving device meets acceptance criteria. Here's a breakdown of why and what information is provided:
This document describes a "Special 510(k) submission" for a change in a small component (a luer cap) within an already cleared medical device (Affinity NT Oxygenator). It is not a standalone study proving the device meets general acceptance criteria for a new device. The purpose of this submission is to demonstrate that the change to the luer cap does not adversely affect the safety and effectiveness of the previously cleared device, maintaining substantial equivalence to the predicate.
Therefore, most of the requested information (sample sizes, expert consensus, MRMC studies, etc.) is not applicable or not provided in the context of this specific regulatory submission.
Here's how to address the prompt based on the provided text:
1. A table of acceptance criteria and the reported device performance
The document doesn't explicitly define acceptance criteria in a quantitative table form for the overall device's performance. Instead, it focuses on demonstrating that the change to the luer cap does not negatively impact the device's functionality. The "acceptance criteria" for this specific change are implicitly tied to maintaining the original device's performance and safety.
| Acceptance Criterion (implicitly for the luer cap change) | Reported Device Performance |
|---|---|
| Biocompatibility | Pass (leveraged from K240534, a higher-risk classification) |
| Functionality (e.g., impact on final product functionality or performance) | Pass (dimensional comparison, torque removal test, pressure integrity test concluded no impact) |
| Performance of the modified device after the change | Substantially Equivalent to legally marketed predicate devices |
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Test Set Sample Size: Not explicitly stated for specific tests related to the luer cap change. The document mentions "Risk-based testing and evaluations," suggesting a sample size appropriate for these specific tests, but the number is not provided.
- Data Provenance: Not specified. Given it's a regulatory submission by Medtronic, it's presumably internal testing conducted to support the change.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
Not applicable. This is a technical validation of a component change, not an evaluation requiring expert clinical interpretation for ground truth.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable. This is not a study requiring adjudication of interpretations.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This is not an AI-enabled device or an MRMC study.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This is not an algorithm-only device.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
For the luer cap change, the "ground truth" is established through engineering and biological testing:
- Biocompatibility: Conformance to ISO 10993-1:2018 standards, which involves specific chemical and biological tests. The "ground truth" here is the pass/fail result based on laboratory analysis against these standards, leveraged from a previous clearance (K240534) for a higher-risk product.
- Functionality: Direct measurements and observations (dimensional comparison, torque removal, pressure integrity) against established engineering specifications.
8. The sample size for the training set
Not applicable. This is not a machine learning or AI device that requires a training set.
9. How the ground truth for the training set was established
Not applicable.
Ask a specific question about this device
(163 days)
The D100 devices are indicated for use for neonatal patients undergoing surgical procedures requiring cardiopulmonary bypass. The oxygenator is intended to be used for six hours or less.
The D101 devices are indicated for use for infant patients undergoing surgical procedures requiring cardiopulmonary bypass The oxygenator is intended to be used for six hours or less
The D100 KIDS and D101 KIDS oxygenators (hereinafter identified as KIDS) consist of an oxygenator with an integrated heat exchanger and hard-shell cardiotomy venous reservoir.
The KIDS consist of the following main components
• a heat exchanger consisting of a grooved and pleated stainless steel that is placed into a polycarbonate housing with integrated Hansen connectors and is sealed with resin potting at both ends. it controls blood temperature and allows the use of hypothermia or aids in the maintenance of normothermia during surgery.
• an oxygenating module element made of a coiled bundle of polypropylene microporous hollow fibers rolled on the heat exchanger sub assembly. The hollow fiber membrane provides oxygenation and carbon dioxide removal from venous blood or suction blood.
• a hard shell cardiotomy/venous reservoir attached to the top of the oxygenator by means of a molded fitting joint. It is a single chamber reservoir comprised of a rigid polycarbonate housing with an internal hollow support. The filtering system surrounds the internal hollow support and work as a cardiotomy section in the upper part and as a venous reservoir in the bottom part. It collects and filter blood coming from suckers and from the venous return.
The provided document is a 510(k) premarket notification for D100 KIDS and D101 KIDS cardiopulmonary bypass oxygenators. It's a regulatory submission and not a research paper detailing an AI/ML device study. Therefore, most of the requested information regarding acceptance criteria and study details for AI/ML performance (such as sample size for test/training sets, expert qualifications, ground truth establishment, MRMC studies, or standalone algorithm performance) is not applicable to this document.
The document focuses on demonstrating substantial equivalence to predicate devices by evaluating the impact of modified materials through non-clinical in vitro testing.
Here's the relevant information that can be extracted:
1. A table of acceptance criteria and the reported device performance
The document states that "The modified device successfully met all acceptance criteria." However, it does not provide a specific table or list of quantitative acceptance criteria and corresponding performance metrics. It only lists the types of tests performed:
| Test Type | Reported Performance (Qualitative) |
|---|---|
| Pull test on modified adaptor kit and purge lines | Successfully met all acceptance criteria |
| Pressure resistance on modified adaptor kit | Successfully met all acceptance criteria |
| Backflow and pressure flow rate on modified one way valve | Successfully met all acceptance criteria |
The document also notes that these tests were conducted on "sterile aged devices; accelerated aging for a period of time equivalent to at least 3 years as per device labeling."
2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)
- Sample size: Not specified. The document only mentions "in vitro testing" without detailing the number of devices or test repetitions.
- Data provenance: In vitro testing; likely performed in Italy (country of the applicant, Sorin Group Italia S.R.L.). The document does not specify if the data is retrospective or prospective, as it's not a clinical study on patient data.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
- This is not applicable. The device is an oxygenator, and the testing involves physical and mechanical performance metrics (pull strength, pressure resistance, flow rates), not a subjective assessment like expert reads of medical images. Ground truth would be established by validated measurement equipment and protocols, not by human experts in this context.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
- This is not applicable. As it's in vitro physical testing, there's no need for adjudication among human readers/experts.
5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
- No. This is not applicable. The device is a medical device (cardiopulmonary bypass oxygenator), not an AI/ML software. No MRMC study was performed.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
- No. This is not applicable. The device is a physical medical device, not an AI/ML algorithm.
7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)
- The "ground truth" for this type of in vitro testing would be established by physical measurements using calibrated instruments, adhering to engineering and performance specifications. For example, a "pull test" would have a specified force threshold, and the device either meets or fails that. There is no biological or clinical "ground truth" in the sense of a diagnosis or outcome.
8. The sample size for the training set
- Not applicable. There is no "training set" as this is not an AI/ML device.
9. How the ground truth for the training set was established
- Not applicable. There is no "training set" as this is not an AI/ML device.
In summary: This document is a regulatory submission for a physical medical device (oxygenator) demonstrating substantial equivalence based on in vitro performance testing of material modifications. It does not involve AI/ML technology or clinical studies with patient data, and therefore, most of the questions relating to AI/ML device performance evaluation are not relevant to this document.
Ask a specific question about this device
(145 days)
Quantum Perfusion Blood Oxygenator with Integrated AF and Sensor VT75-C1U is a diffusion membrane oxygenator, designed to provide gas exchange during cardiac surgery requiring cardiopulmonary bypass, to measure blood pressure and temperature during the procedure. The integrated arterial filter provides additional protection against air and solid emboli. The device is limited to 6 hours of use.
Device is intended for Adolescent and Transitional Adolescent patients (from 12 to 21 years old age).
Quantum Perfusion Blood Oxygenator with Integrated AF VT75-C2U is a diffusion membrane oxygenator, designed to provide gas exchange during cardiac surgery requiring cardiopulmonary bypass and to measure temperature during the procedure. The integrated arterial filter provides additional protection against air and solid emboli. The device is limited to 6 hours of use.
Devices is intended for Adolescent and Transitional Adolescent patients (from 12 to 21 years old age).
Quantum Perfusion Blood Oxygenator devices, VT75-C1U and VT75-C2U, consist of an oxygenator with an integrated arterial filter. The Quantum Perfusion Blood Oxygenator device is designed to provide gas exchange during cardiac surqical procedures requiring cardiopulmonary bypass for a maximum duration of 6 hours. The device has microporous hollow fibers, made of Polypropylene (PP) and with high gas permeability, that allow gas exchange. The integrated arterial filter provides additional protection against air and solid emboli. Blood enters the oxygenator through the blood inlet connector, flows through a blood chamber, touching the outer surface of a hollow fiber membrane, exits the oxygenator with the desired level of gas exchange. The device is non-toxic, non-pyrogenic, sterilized by ethylene oxide and packaged in a single box. All the device surfaces in contact with a phosphorylcholine-based biocompatible coating.
The provided text describes a 510(k) premarket notification for a medical device, the "Quantum Perfusion Blood Oxygenator with Integrated AF and Sensor VT75-C1U" and "Quantum Perfusion Blood Oxygenator with Integrated AF VT75-C2U". This document outlines the device's characteristics, intended use, and comparison to predicate devices. It states that the submission does not include clinical data and relies on non-clinical testing to demonstrate substantial equivalence.
Therefore, many of the requested elements for describing "acceptance criteria and the study that proves the device meets the acceptance criteria" in the context of an AI/ML powered device, particularly those related to human-in-the-loop performance, expert ground truth, and training sets, are not applicable to this submission. This device is a traditional medical device (oxygenator), not an AI/ML-powered diagnostic or therapeutic tool.
Here's a breakdown of the requested information based on the provided document, highlighting what is present and what is not applicable:
1. A table of acceptance criteria and the reported device performance
The document lists performance tests conducted, but does not provide a table with specific quantitative acceptance criteria or detailed reported performance values for the device alongside those criteria. It only states that "all testing passed by meeting the established requirements."
| Test Category | Acceptance Criteria (from document) | Reported Device Performance (from document) |
|---|---|---|
| Gas Exchange testing | "meeting the established requirements" (not specified quantitatively) | "all testing passed" |
| Mechanical Hemolysis | "meeting the established requirements" (not specified quantitatively) | "all testing passed" |
| Leakage testing | "meeting the established requirements" (not specified quantitatively) | "all testing passed" |
| Filtration efficiency | "meeting the established requirements" (not specified quantitatively) | "all testing passed" |
| Pressure drop testing | "meeting the established requirements" (not specified quantitatively) | "all testing passed" |
| Priming volume characterization | "meeting the established requirements" (not specified quantitatively) | "all testing passed" |
| Biocompatibility | According to ISO 10993-1: 2018 and FDA Guidance | Animal studies performed for mandatory biocompatibility tests, passed. (Specific results not detailed) |
2. Sample sizes used for the test set and the data provenance
The document does not specify sample sizes for the non-clinical performance tests (e.g., how many oxygenators were tested for gas exchange). The tests are described as "non-clinical testing" and appear to be laboratory or bench testing. Data provenance is not applicable in the sense of patient data; it's device performance testing.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts
Not applicable. This device is an oxygenator, not an AI/ML diagnostic. Ground truth would be defined by engineering specifications and physical measurements, not expert consensus on medical images or clinical data.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
Not applicable. This concept pertains to human review of ground truth in AI/ML performance studies, which is not relevant here.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
Not applicable. This is not an AI-assisted device. The submission explicitly states "No clinical data have been included in the current 510(k) submission to support substantial equivalence to legally marketed predicate devices."
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
Not applicable. This is not an AI/ML algorithm. The performance tests mentioned (gas exchange, hemolysis, etc.) are inherent performance characteristics of the physical device.
7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)
For this type of traditional medical device, "ground truth" for performance relates to:
- Engineering specifications and standards: Adherence to established performance parameters outlined in standards like ISO 7199 for Cardiopulmonary Bypass Oxygenators.
- Physical and chemical measurements: Examples include flow rates, pressure drops, gas transfer rates (O2 and CO2), and hemolysis rates.
- Biocompatibility testing results: As per ISO 10993.
8. The sample size for the training set
Not applicable. This is not an AI/ML-powered device that requires a training set.
9. How the ground truth for the training set was established
Not applicable. As above, this is not an AI/ML-powered device.
Ask a specific question about this device
(169 days)
The CMO8 Adult PMP Oxygenator is a hollow fiber membrane oxygenator intended for physiologic gas exchange in adults and small adults undergoing cardiopulmonary bypass surgery. The integrated heat exchanger makes it possible to regulate the blood temperature. The CMO8 Adult PMP Oxygenator is intended for up to 6 hours. The Tubing Pack is intended for use in extracorporeal crculation during cardiopulmonary bypass procedures, lasting 6 hours or less.
The CMO8 Adult PMP oxygenator (CMO8) is a hollow fiber membrane oxygenator with an integrated heat exchanger. The CMO8 facilitates the gas exchange into and out of the blood, and the regulation of blood temperature during cardiopulmonary bypass. The CMO8 is supplied with a Rheopak surface coating that reduces platelet adhesion to coated surfaces. The qas exchanger part of the CMO8 is formed of plasma tight hollow fiber membranes. The gas flow takes place through the inner lumen of the fibers. Blood is in contact with the outer side of the membranes, so that oxygen can diffuse into the venous blood, while carbon dioxide diffuses out of the blood. The heat exchanging part of the CMO8 is made of non-porous hollow fiber membranes. Water flows through the inner lumen of the fibers, so that blood temperature flowing outside is regulated. The Tubing Pack, which contains blood lines, gas lines, a venous reservoir and the CMO8 Oxygenator, is a component of a cardiopulmonary bypass procedure that facilitates extracorporeal circulatory support for a term of up to 6 hours.
The provided text is a 510(k) summary for a medical device (CMO8 Adult PMP Oxygenator with Tubing Pack) and not a report or study describing the acceptance criteria or performance of an AI/ML powered device.
Therefore, I cannot extract the requested information regarding acceptance criteria and a study proving an AI/ML device meets them from this document. The document primarily discusses the substantial equivalence of a physical medical device (an oxygenator) to predicate devices through in vitro and non-clinical testing.
The questions you asked are highly relevant to AI/ML device submissions, particularly regarding:
- Acceptance Criteria and Performance Table: This is typically a key component of AI/ML device validation.
- Sample Size and Data Provenance: Crucial for understanding the representativeness and generalizability of AI/ML model testing.
- Expert Ground Truth (Number of Experts, Qualifications, Adjudication): Essential for establishing reliable labels for AI/ML training and testing data.
- MRMC Studies: Often used to evaluate the impact of AI on human reader performance.
- Standalone Performance: Evaluating the AI algorithm's capabilities independently.
- Type of Ground Truth: The gold standard used to assess AI accuracy.
- Training Set Details: Information about the data used to develop the AI model.
To answer your request, I would need a document detailing the clinical validation or performance study for an AI/ML-powered medical device.
Ask a specific question about this device
Page 1 of 15