The Vivo 45 LS ventilator (with or without the SpO2 and CO2 sensors) is intended to provide continuous or intermittent ventilatory support for the care of individuals who require mechanical ventilation. Specifically, the ventilator is applicable for pediatric through adult patients weighing more than 5 kg (11 lbs.), however, the mouthpiece ventilation and Auto EPAP modes are only for adult patients during non-invasive ventilation.
The Vivo 45 LS with the SpO2 sensor is intended to measure functional oxygen saturation of arterial hemoglobin (%SpO2) and pulse rate.
The Vivo 45 LS with the CO2 sensor is intended to measure CO2 in the inspiratory and expiratory gas.
The device is intended to be used in home, institution, hospitals and portable applications such as wheelchairs and gurneys. It may be used for both invasive and non-invasive ventilation. The Vivo 45 LS is not intended to be used as an emergency transport or critical care ventilator. The Auto EPAP feature is for use with PSV+TgV+AE mode in hospital use only.
The Vivo 45 LS Ventilator is a portable, microprocessor controlled turbine based pressure support, pressure control or volume controlled ventilator intended for the care of individuals who require mechanical ventilation.
Flow and pressure are read using flow and pressure sensors. Essential parameters such as pressure, flow and volume are presented on the ventilator screen, both in the form as graphs and numbers.
Operator actions are performed via the front panel where the buttons and an LCD screen are located (and two dedicated buttons on the top of the ventilator control starting/stopping treatment and pausing the alarm audio). There are dedicated LEDs and buttons for managing alarm conditions and an Information button which provides integrated user support.
The Vivo 45 LS can be operated by external AC or DC power supply and contains an integrated battery as well as an optional click in battery.
The Vivo 45 LS can be used with two types of patient circuits: single limb patient circuits including an active exhalation valve and single limb patient circuits including a passive leakage port.
N/A
Ask a specific question about this device
(61 days)
The Fisher & Paykel Healthcare single-patient use masks are intended for use as an accessory to ventilators to enable non-invasive positive pressure ventilation (NPPV) therapy (CPAP or bi-level) to be delivered to spontaneously breathing adult patients (> 30 kg) with respiratory insufficiency or respiratory failure who have been prescribed NPPV. The masks are to be fitted and therapy maintained, by trained medical practitioners in a hospital/institutional environment with patient monitoring in place.
The F&P OptiNIV Vented Full Face Masks are oro-nasal full face masks that are intended for use as an accessory to deliver non-invasive positive pressure ventilation (NPPV) to a patient as part of a non-invasive ventilation system.
The OptiNIV Vented Full Face Masks are prescription-only, provided in a non-sterile state.
The F&P OptiNIV Vented Full Face Mask consists of a plastic shell with a seal to allow cushioning onto the patient's face, and straps to enable the mask to be secured over the head. The mask fits under the patient's nose and covers the nares of the nose and the mouth, with a soft seal to maintain pressure inside the mask whilst minimizing discomfort to the user.
The subject device is available in three sizes – A, B, and C to denote the seal sizes.
N/A
Ask a specific question about this device
(265 days)
The SV600, SV800 Ventilator is intended to be used in intensive care situations for long-term or during transport within a professional healthcare facility. The SV600, SV800 Ventilator is intended to provide ventilation assistance and breathing support for adult, pediatric and neonate patients with a minimum body weight of 0.5 kg. The SV600, SV800 Ventilator should be operated by properly-trained and authorized medical personnel. This equipment is not suitable for use in an MRI environment.
The SV600 and SV800 Ventilators are pneumatically-driven and electronically-controlled ventilators. The Ventilators consists of a main unit (including pneumatic circuit, electronic system, mechanical structure, display, CO2 module, SpO2 module), trolley and support arm. The device also includes a neonatal flow sensor and neonatal flow sensor cable, which are used to measure the patient inspiration/expiration flow in neonatal ventilation modes.
The provided FDA 510(k) Clearance Letter for the SV600, SV800 Ventilator describes modifications to an existing device, primarily the addition of neonatal ventilation capabilities and updated monitoring modules. However, the document does not contain the level of detail typically found in a clinical study report for evaluating acceptance criteria and device performance in the way you've requested for studies involving AI algorithms, image analysis, or expert consensus with specific metrics like sensitivity, specificity, or AUC.
This document focuses on providing evidence of substantial equivalence to predicate devices through technical comparisons and various forms of bench testing, software verification, and compliance with consensus standards. It does not present a performance study with acceptance criteria specific to an AI device's output (e.g., accuracy against ground truth, reader performance improvements).
Therefore, I cannot fill out your requested table and answer many of your specific questions as the information is not present in the provided text.
Here's what can be extracted based on the document's content:
Acceptance Criteria and Device Performance (Based on available information)
The document doesn't define "acceptance criteria" in terms of specific performance metrics (like sensitivity, specificity, accuracy) that would be typically found for an AI or diagnostic device. Instead, "acceptance criteria" are implied by compliance with various technical specifications and international standards. Device performance is generally reported as "meets specifications" or "is equivalent to the predicate."
| Acceptance Criteria (Implied by Standards/Specifications) | Reported Device Performance (Summary) |
|---|---|
| Biocompatibility: Conformance to ISO 10993 and ISO 18562 series. | Testing performed, device meets standards. |
| Software Verification & Validation: Conformance to FDA Guidance for Software. | Verification and validation conducted; product works as designed and meets design/performance checks. |
| Electromagnetic Compatibility (EMC) & Electrical Safety: Conformance to IEC 60601-1 and related collateral standards. | Testing performed, device meets standards. |
| Functional & System Level Performance (Bench Testing): Meets accuracy specifications and demonstrates equivalence to predicate for new/modified features (e.g., neonatal ventilation parameters, CO2/SpO2 modules). | Bench testing shows device meets accuracy specifications and is substantially equivalent to the predicate. |
| Usability: Conformance to IEC 60601-1-6. | Testing performed, ensuring usability. |
| Alarm Systems: Conformance to IEC 60601-1-8. | Testing performed, ensuring alarm system effectiveness. |
| Critical Care Ventilator Specifics: Conformance to ISO 80601-2-12. | Testing performed, device meets standards. |
| Respiratory Gas Monitors: Conformance to ISO 80601-2-55. | Testing performed, device meets standards. |
| Pulse Oximeter Equipment: Conformance to ISO 80601-2-61. | Testing performed, device meets standards. |
| Ventilator Endurance: Conformance to ASTM F1100-90. | Testing performed, ensuring endurance. |
| Key Technical Parameters (e.g., TV range, O2% range, SpO2 accuracy): Achieves specified ranges and accuracies (as detailed in the comparison tables). | The comparison tables indicate specific ranges and accuracies for various parameters, demonstrating the device's adherence to these specifications (e.g., SpO2 accuracy of ±2% for adult/pediatric, ±3% for neonate in certain ranges). |
Study Details (Based on available information in the 510(k) Summary)
-
Sample size used for the test set and the data provenance:
- The document does not specify sample sizes for test sets in the context of clinical performance evaluation (e.g., number of patients, number of readings). The "testing" mentioned refers to engineering, software, and standards compliance evaluations.
- Data provenance is not provided, as this is not a clinical study report.
-
Number of experts used to establish the ground truth for the test set and the qualifications of those experts:
- Not applicable. The document describes engineering and standards compliance testing, not a clinical study involving expert-established ground truth for performance evaluation of an AI component or diagnostic output.
-
Adjudication method (e.g. 2+1, 3+1, none) for the test set:
- Not applicable. This is not a clinical study with an adjudication process for ground truth.
-
If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance:
- No MRMC comparative effectiveness study was done. This document describes a ventilator, not an AI diagnostic or assistance tool in that context. While it includes "Intellicycle" and "Lung Recruitment (SI)" features, these are not presented as AI assistance augmenting human reader performance in a diagnostic capacity.
-
If a standalone (i.e. algorithm only without human-in-the-loop performance) was done:
- The document implies standalone performance testing for various technical aspects of the ventilator and its integrated modules (CO2, SpO2 sensors) against their respective specifications and standards. For example, SpO2 sensor accuracy is stated as "Measurement accuracy: 70 to 100%: ±2% (adult/pediatric mode)" for the Mindray SpO2 module. However, this is for sensor performance, not a complete "algorithm only" evaluation in the context of AI diagnostic output as typically measured.
-
The type of ground truth used (expert consensus, pathology, outcomes data, etc):
- For the technical and performance testing, the "ground truth" would be established by reference standards, calibrated equipment, and design specifications. For example, a flow sensor's accuracy would be tested against a known, precise flow rate. For biocompatibility, the ground truth is defined by the toxicological profiles dictated by the ISO standards. For software, the ground truth is the functional requirements and design specifications.
- There is no mention of expert consensus, pathology, or outcomes data being used to establish ground truth for clinical performance evaluation of an AI component.
-
The sample size for the training set:
- Not applicable. This document does not describe the development or validation of an AI algorithm with a training set. The "Intellicycle" feature is mentioned, but no details regarding its development, training data, or validation as an AI algorithm are provided.
-
How the ground truth for the training set was established:
- Not applicable, as no AI training set is described.
Summary Limitations:
The provided text is a 510(k) summary, which aims to demonstrate substantial equivalence to legally marketed predicate devices. It details technical changes, compliance with regulatory standards (e.g., biocompatibility, electrical safety, EMC, software V&V), and functional testing results. It does not outline a clinical performance study with the types of metrics and methodologies commonly associated with evaluating AI-driven diagnostic devices or those requiring expert consensus for ground truth. Therefore, many of your specific questions are not addressed by the provided document.
Ask a specific question about this device
(27 days)
The AVEA Disposable Expiratory Filter/ Water Trap is an expiratory filter and water trap for use with the AVEA Ventilator.
It would be used in an institutional healthcare environment (e.g., hospitals). It may be used on adult, pediatric, and neonatal patients.
It should be operated by properly trained clinical personnel, under the direction of a physician.
The AVEA disposable expiratory filter/water trap is designed to be used exclusively with the AVEA Ventilator.
This document is a 510(k) clearance letter for the AVEA Disposable Expiratory Filter/Water Trap. It declares the device substantially equivalent to a predicate device and provides the regulatory information. Crucially, it does not describe a clinical study of the device against acceptance criteria for performance; instead, it relies on demonstrating identicality to a previously cleared predicate device.
Therefore, I cannot provide the requested information regarding:
- A table of acceptance criteria and reported device performance.
- Sample sizes, data provenance, and expert details for a test set.
- Ground truth establishment and adjudication methods.
- MRMC comparative effectiveness study results.
- Standalone AI algorithm performance (as this is a physical medical device, not an AI software).
- Training set sample size or ground truth establishment for a training set.
The document explicitly states:
- "The subject and predicate devices are identical in all ways."
- "The subject device and the predicate – AVEA disposable expiratory filter/water trap – K081837 is substantially equivalent based upon identicality."
This means that the study proving the device meets acceptance criteria for this specific 510(k) relies purely on the fact that it is a direct copy of a previously cleared device. The "acceptance criteria" here are essentially "be identical to the predicate device."
Here's what can be extracted from the document related to performance, based on the predicate device's listed performance:
1. Table of Acceptance Criteria (as per predicate device's listed performance) and Reported Device Performance (by virtue of identicality)
| Performance Parameter | Acceptance Criteria (based on Predicate) | Reported Device Performance (Identical to Predicate) |
|---|---|---|
| Viral Filtration Efficiency (VFE) / Bacterial Filtration Efficiency (BFE) | 99.999% | 99.999% |
| DOP / POA Efficiency | 99.97% | 99.97% |
| Flow Resistance | < 1 cmH2O at 60 lpm | < 1 cmH2O at 60 lpm |
| Flow Leakage | < 0.01 lpm at 140 cmH2O internal pressure | < 0.01 lpm at 140 cmH2O internal pressure |
| Internal Volume | 500 ml (includes Water trap of 130 ml) | 500 ml (includes Water trap of 130 ml) |
| Dimensions | Diameter – 9.7 cm, Height – 33 cm | Diameter – 9.7 cm, Height – 33 cm |
| Biocompatibility | Tested per ISO 10993 | Tested per ISO 10993 |
2. Sample size used for the test set and the data provenance (e.g., country of origin of the data, retrospective or prospective)
This information is not available in the provided document. As the clearance is based on identicality to a predicate, no new performance testing data (and thus no test set or its provenance) for the subject device is presented. The document mentions "Bench testing: Testing was not listed in K081837" and "Identical to K081837" for the subject device. This suggests that the original predicate device (K081837) also didn't explicitly list specific bench testing details in its 510(k) summary, or at least not in a way that is reproduced here.
3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)
This information is not applicable/not available. This is a physical device, not an AI or diagnostic imaging device that requires expert review for ground truth establishment.
4. Adjudication method (e.g. 2+1, 3+1, none) for the test set
This information is not applicable/not available for the same reasons as point 3.
5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance
This information is not applicable/not available. This is a physical device (expiratory filter/water trap), not an AI-assisted diagnostic tool.
6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done
This information is not applicable/not available for the same reasons as point 5.
7. The type of ground truth used (expert concensus, pathology, outcomes data, etc)
For the physical properties (VFE, BFE, flow resistance, leakage, dimensions, volume), the "ground truth" would be established through laboratory bench testing according to relevant standards. For biocompatibility, it's established through testing per ISO 10993. The document states identicality to the predicate for these, implying that the predicate's performance claims serve as the reference.
8. The sample size for the training set
This information is not applicable/not available. This is a manufactured physical device, not a machine learning model that requires a training set.
9. How the ground truth for the training set was established
This information is not applicable/not available for the same reasons as point 8.
In summary, the "study" proving this device meets acceptance criteria (for a 510(k)) is simply the demonstration that it is geometrically and functionally identical to a previously cleared predicate device that has established safety and effectiveness. No new clinical or extensive performance studies were required for this specific 510(k) because of this identicality.
Ask a specific question about this device
(60 days)
Medium and Large Size: The AF531 Oro-Nasal SE Face Mask is intended to provide a patient interface for application of noninvasive ventilation. The mask is to be used as an accessory to ventilators which have adequate alarms and safety systems for ventilation failure, and which are intended to administer CPAP or positive pressure ventilation for treatment of respiratory failure, respiratory insufficiency, or obstructive sleep apnea. The mask is for single use in the hospital/institutional environment only. The mask is to be used on patients (>30 kg) who are appropriate candidates for noninvasive ventilation.
Small Size: The AF531 Oro-Nasal SE Face Mask is intended to provide a patient interface for application of noninvasive ventilation. The mask is to be used as an accessory to ventilators which have adequate alarms and safety systems for ventilation failure, and which are intended to administer CPAP or positive pressure ventilation for treatment of respiratory failure, respiratory insufficiency, or obstructive sleep apnea. The mask is for single use in the hospital/institutional environment only. The mask is to be used on patients 7 years or older (>20 kg) who are appropriate candidates for noninvasive ventilation.
The AF531 Oro-Nasal SE Face Mask is designed for single-patient use in the hospital or institutional environment. AF531 Oro-Nasal SE Face Mask covers the nose and mouth while avoiding the eye region. The mask is available in three (3) sizes: Small, Medium, and Large.
The headgear options for the AF531 Oro-Nasal Masks include the four-point headgear and a CapStrap headgear.
The AF531 Oro-Nasal SE Face Mask requires use of a separate exhalation device. The mask utilizes a click-style elbow that secures to the mask hub yet can be removed by pressing the release tabs.
The document describes a medical device, the AF531 Oro-Nasal SE Face Mask, and its substantial equivalence to predicate devices, rather than a study on an AI/ML powered device. Therefore, it does not contain the information required to answer your query regarding acceptance criteria and performance studies for an AI/ML device.
Specifically, the document does not provide:
- A table of acceptance criteria and reported device performance for an AI/ML model.
- Sample sizes used for a test set (in the context of AI/ML).
- Data provenance (country of origin, retrospective/prospective) for AI/ML data.
- Number of experts or their qualifications for establishing ground truth for AI/ML.
- Adjudication method for AI/ML ground truth.
- Details of a Multi-Reader Multi-Case (MRMC) comparative effectiveness study.
- Results of a standalone (algorithm only) performance study.
- Type of ground truth used (expert consensus, pathology, outcomes data) for AI/ML.
- Sample size for a training set in an AI/ML context.
- How ground truth for a training set was established for an AI/ML model.
The document is a 510(k) summary for a physical medical device (a face mask for ventilation) and focuses on demonstrating substantial equivalence based on intended use, design, materials, and performance specifications relevant to a physical component. The "Non-Clinical Data Submitted" section lists engineering and biological performance tests (e.g., total mask leak, pressure drop, sound testing, biocompatibility), not AI/ML model performance metrics.
Ask a specific question about this device
(413 days)
Each model of the ZOLL 731 Series of Ventilators is indicated for use in the management of infant through adult patients weighing greater than or equal to 5 kg with acute or chronic respiratory failure or during resuscitation by providing continuous positive-pressure ventilation. ZOLL Ventilators are appropriate for use in hospitals, outside the hospital, during transport and in severe environments where they may be exposed to rain, dust, rough handling, and extremes in temperature and humidity. With an appropriate third-party filter in place, they may be operated in environments where chemical and/or biological toxins are present. When marked with an "MRI conditional" label, ZOLL ventilators are suitable for use in an MRI environment with appropriate precautions. ZOLL ventilatiors are intended for use by skilled care providers with knowledge of mechanical ventilation, emergency medical services (EMS) personnel with a basic knowledge of mechanical ventilation, and by first responders under the direction of skilled medical care providers.
The ZOLL Ventilator pulse oximeter with Masimo SET technology is intended for use for continuous noninvasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO2), and pulse rate. The pulse SpO2 oximeter and accessories are indicated for use on adult, pediatric, and neonatal patients during both no motion conditions, and for patients who are well or poorly perfused, in hospitals, hospital-type facilities, or in mobile environments.
The ZOLL 731 Series Ventilators family consists of AEV, EMV+, Eagle II and Z Vent models which are small, durable, full-featured portable mechanical ventilators which provide ventilatory support for infants (≥ 5 kg), pediatric and adult patients. 731 Series ventilators are designed to operate in hospitals, prehospital, and field hospital settings. The ventilators can be operated from an AC or DC external power source, or from an integrated battery system, and support the following pressure and volume ventilation modes: Assist/Control (AC), Synchronized Intermittent Mandatory Ventilation (SIMV) with or without Pressure Support (PS), Continuous Positive Airway Pressure (CPAP) with or without PS, with and without Noninvasive Positive Pressure ventilation (NPPV) Positive Pressure Ventilation (PPV).
The provided document is a 510(k) premarket notification letter and summary for the ZOLL 731 Series Ventilator. It details the device, its intended use, and the comparisons made to a predicate device to establish substantial equivalence.
However, the request asks for information about acceptance criteria and a study that proves a device meets those criteria, specifically in the context of an AI/algorithm-driven medical device. The document provided does not describe an AI/algorithm-driven device. Instead, it is for a ventilator (a mechanical device with updated software), and the "study" referred to is primarily non-clinical evidence (software verification and validation testing, safety testing per international standards, electrical safety, EMC, and usability testing with no changes to the UI). There is no mention of an algorithm or AI that generates outputs requiring ground truth, expert adjudication, or MRMC studies for evaluation.
Therefore, I cannot fulfill the request with the provided input because the input document does not contain the necessary information about acceptance criteria and studies for an AI/algorithm-driven device.
The document explicitly states:
- "Clinical evidence was not necessary to show substantial equivalence."
- The primary change is a "software revision 5.25, which updates the ventilator alarm logic." This is a rule-based or programmatic change, not an AI/ML model.
- The comparison is based on "Alarm System, Functions and Features, Indications for Use, Intended Use, Labeling, Pulse Oximeter Specifications, Ventilator Specifications." These are typical for traditional medical device updates, not AI.
If the request refers to general device acceptance criteria and testing (not specific to AI/algorithms), then the relevant parts of the document are the "Substantial Equivalence - Non-Clinical Evidence" section, which details the various tests and standards met:
- Software Verification and Validation Testing: This is the primary "study" proving the device meets its software-related acceptance criteria. The document states this testing "ensured that the 731 Series Ventilators performs as well as the indicated predicate devices and met all its functional requirements and performance specifications."
- Safety Testing per International Standards: Compliance with a long list of international standards (IEC 60601-x, ISO 15223-1, EN 1789, etc.) serves as the acceptance criteria for safety and effectiveness in various aspects. The "Table 1: 731 Series Ventilator Compliance Standards" lists these.
- Usability Testing: The document states "No usability validation is included in this plan. The user interface remains unchanged." This implies that the acceptance criterion for usability was "no change from predicate" and thus no new testing was needed.
- Electrical Safety and Electromagnetic Compatibility (EMC): Tested to meet applicable standards listed in Table 1.
However, the request is very specific about AI-related evaluation elements (MRMC, standalone algorithm, ground truth methods, training set, etc.), which are entirely absent from the provided document.
Ask a specific question about this device
(791 days)
The Ventoux is intended to provide continuous or intermittent mechanical ventilation support for the care of individuals who require mechanical ventilation. Specifically, the Ventoux is applicable for adult and pediatric (i.e., infant, child and adolescent) patients who weigh at least 5 kg (11 lbs).
The Ventoux is a restricted medical device intended for use by qualified, trained personnel under the direction of a physician; it is suitable for use in hospital environments.
The Ventoux Ventilator is an electrically powered, microprocessor-controlled multi-parameter ventilator, which can be: Time, Pressure, Flow or Volume triggered; Volume or Pressure controlled; Time or Flow cycled.
Manual inflation is allowed, and the Ventoux supports the emergency intake of ambient air which permits the patient to pull ambient air into the breathing circuit in the event of a complete loss of air/gas supply.
Volume triggered is based on Inspiratory trig response time ≤100 ms from pressure drop/flow rise to PEEP level.
Ventilation is possible in both Invasive and Noninvasive settings.
The system can be expanded to include additional parameter monitoring to allow for Sp02, etC02 and Cuff Pressure Control.
The Ventoux can be powered by external power (100 – 240 VAC, 50-60 HZ or 10 – 30 VDC) and/or by its two swappable internal Li Ion rechargeable batteries, which provide full operating power the to the ventilator for a minimal operating time of 6 hours when operating on standard ventilation parameters.
A comprehensive alarm system is built-in to alert the user to violations of set safety limits. The alarm system alerts the care giver by activating the audible alarm, screen display and the LED indicator.
The electrical system is comprised of three primary boards: The main board (motherboard) which holds the majority of the electronics including the main CPU and the display CPU. the power board, which holds the power subsystems, and internal communication functions, and the Communication board, which holds internal communication and external communication connectors. The main component of the pneumatic system is an electrically controlled compressor (pump). This compressor provides a compressed gas source so no external air compressor is needed. Additionally, the exhalation valve is activated by an electrically controlled proportional solenoid that provides a built in PEEP.
The provided FDA 510(k) summary (K223120 for the Ventoux Ventilator) does not contain information about an AI/ML powered device. The document describes a traditional medical device (a continuous ventilator) and its comparison to predicate devices based on established engineering and performance standards.
Therefore, I cannot extract the requested information regarding acceptance criteria, study details, human reader improvement with AI assistance, or ground truth establishment for an AI/ML model. The 510(k) summary specifically states:
"No clinical testing was conducted or required in support of this premarket notification." and "The software design and validation process, together with the bench testing of the device, demonstrated Ventoux Ventilator performs as intended."
This indicates that the device's performance was validated through bench testing and compliance with recognized standards, not through studies involving AI/ML performance metrics, expert consensus, or multi-reader studies as would be typical for AI-powered diagnostic aids.
The document focuses on:
- Technological Characteristics Comparison: Showing the Ventoux has similar features and functionalities to predicate devices.
- Performance Data: Demonstrating compliance with various IEC and ISO standards related to electrical safety, EMC, basic safety and essential performance of ventilators, alarm systems, gas monitors, pulse oximeters, environmental testing (shock, rough handling, vibration), altitude, internal temperature, and battery validation.
- Software Design and Validation: Stating that this was performed and contributed to demonstration of intended performance.
- Bench Testing: Stating that bench testing was conducted to verify compliance with predefined specifications and internal procedures.
- Biocompatibility: Assessment of gas pathways.
To answer your request, an AI/ML-specific device submission would be needed, which would detail metrics like sensitivity, specificity, AUC, and studies with expert readers. This document does not provide such information.
Ask a specific question about this device
(203 days)
The RESPOND(R) Ventilator provides continuous or intermittent positive pressure ventilation for the care of individuals who require mechanical ventilation. The RESPOND(R) Ventilator is intended for pediatric through adult patients weighing at least 38 kg.
The RESPOND(R) Ventilator is intended for use in a hospital transport, and institutional environments such as long-term acute care, skilled nursing facilities, long-term care, and subacute care facilities.
The RESPOND(R) Ventilator is intended for use by qualified, trained personnel under the direction of a licensed clinician.
The RESPOND® Ventilator is a multi-patient continuous ventilator intended to mechanically control or assist patient breathing by delivering a predetermined percentage of oxygen/air to the breathing gas.
The ventilator provides both pressure control and volume modes of therapy and can provide both invasive and non-invasive ventilation. The device is compatible with both passive HME and heated humidification patient circuits, as well as nebulization with an ultrasonic nebulizer. The ventilator is equipped with an oxygen mixing module, which allows oxygen to be delivered to the patient within a range of 21% to 95% concentration.
The RESPOND® Ventilator provides continuous or intermittent positive pressure ventilation for the care of individuals who require mechanical ventilation. RESPOND® is intended for pediatric and adult patients weighing at least 38 kg (84 lbs.) and is intended for use in a hospital including intra-hospital transport, and institutional environments such as long-term acute care, skilled nursing facilities, long-term care, and subacute care facilities. The RESPOND® Ventilator is intended for use by qualified and trained personnel.
I am sorry, but the provided text does not contain the requested information about acceptance criteria, device performance, sample size, ground truth, or study details. The document is a 510(k) summary for a medical device (RESPOND® Ventilator), primarily focused on demonstrating substantial equivalence to a predicate device. It discusses the device's indications for use, technological characteristics, and a broad overview of non-clinical performance testing without providing specific acceptance criteria or detailed study results in the format you've requested.
Ask a specific question about this device
(57 days)
Ask a specific question about this device
Page 1 of 28