Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K994373

    Validate with FDA (Live)

    Date Cleared
    2000-03-24

    (88 days)

    Product Code
    Regulation Number
    892.1570
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Diagnostic ultrasound imaging or fluid flow analysis of the human body as follows: Trans-esoph. (non-Cardiac) and Trans-esophageal (Cardiac).

    Device Description

    The HDI 1500/SA 8800 system is a general purpose, mobile, software controlled, diagnostic ultrasound system. Its function is to acquire ultrasound data and to display the data as B-mode, M-mode, Color-Flow Doppler, Continuous (CW) Doppler, Pulsed (PW) Doppler and Power Doppler, or as a combination of these modes. The HDI 1500/SA 8800 also gives the operator the ability to measure anatomical structures and offers analysis packages that provide information that is used to make a diagnosis by competent health care professionals. The HDI 1500/SA 8800 has real time acoustic output display with two basic indices, a mechanical index and a thermal index, which are both automatically displayed.

    The MPT7-4 transducer is a multi-element ultrasound transducer mounted on a gastroscopic articulating device. The transducer elements are electronically time- and phase-coordinated to generate a steered and focused ultrasound beam, which produces a high-resolution real-time image. The transducer allows a circular continuum of tomographic images within a 185-degree arc without moving the transducer.

    The MPT7-4 has a transducer array that rotates along an axis perpendicular to the axis of the probe shaft. At 0-degree orientation, the acquired tomographic plane is equivalent to the transverse plane, and at approximately 90-degree orientation, sagittal plane images can be obtained with the transducer array about 30 cm from the patient's teeth. The transducer array can be rotated up to 180 degrees, which provides a mirror image of the 0-degree orientation. Multiple tomographic image planes are continuously selected by rotating the transducer array without significant manipulation of the MPT7-4 transducer.

    The MPT7-4 transducer is used for cardiac and non-cardiac transesophageal 2D and M-mode imaging, pulsed-wave and continuous-wave Doppler, and Color Doppler imaging.

    Biopsy guidelines are provided on screen to assist in the collection of tissue samples, using biopsy guide adapters offered as an optional accessory. The Biopsy guides are the same as those previously cleared for the predicate device, ATL's HDI 5000 system (K961459). The operating Modes of HDI 1500/SA 8800 system are B-Mode, M, Color-Flow Doppler, Continuous wave (CW) Doppler, Pulsed (PW) Doppler, Power Doppler, or as a combination of these modes. Mmode uses the sweep display method, which has its images flow from the left to the right on the monitor. The HDI 1500/SA 8800 system supports the Cine function (capable of storing up to 64 sequential images) and real-time zoom function to the region-of-interest. The system provides the ability to perform remote viewing of images, without compression, via a Dicom 3.0 compatible output. Management of patient history is possible by image-filing function. High-resolution images are provided by utilizing a technology called digital dynamic receive focusing.

    AI/ML Overview

    The provided text does not contain information about acceptance criteria or a study proving the device meets acceptance criteria. The document is a 510(k) summary for a diagnostic ultrasound system and transducer, primarily focused on establishing substantial equivalence to predicate devices and outlining the device's technical characteristics, intended uses, and compliance with safety standards.

    Therefore, I cannot fulfill your request for information regarding acceptance criteria and a study that proves the device meets them, as this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1