    K Number
    K251241

    Validate with FDA (Live)

    Date Cleared
    2025-07-02

    (71 days)

    Product Code
    Regulation Number
    888.3560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Intended Use:

    The EMPOWR Revision Knee™ Symmetric TT Cones are intended for use in skeletally mature patients with bone defect or poor bone quality (osteoporotic bone) or in case of sclerotic bone that requires supplemental fixation in the clinical judgment of the surgeon. The EMPOWR Revision Knee™ Symmetric TT Cones are intended for uncemented fixation to the bone and are fixed to the femoral and tibial implants using bone cement.

    Indications for Use:

    The EMPOWR Revision Knee™:

    Total joint replacement is indicated for patients suffering from disability due to:

    • degenerative, post-traumatic or rheumatoid arthritis;
    • avascular necrosis of the femoral condyle;
    • post-traumatic loss of joint configuration, particularly when there is patellofemoral erosion, dysfunction or prior patellectomy;
    • moderate valgus, varus or flexion deformities;
    • treatment of fractures that are unmanageable using other techniques.

    This device may also be indicated in the salvage of previously failed surgical attempts where bone loss may require the use of augments, sleeves cones or extensions.

    The EMPOWR Revision Knee™ Symmetric TT Cones are indicated for the following conditions:

    • EMPOWR Revision Knee™ Symmetric TT Cones are indicated for use in skeletally mature patients with bone defect or poor bone quality (osteoporotic bone) or in case of sclerotic bone that requires supplemental fixation in the clinical judgment of the surgeon.
    • EMPOWR Revision Knee™ Symmetric TT Cones are indicated for uncemented fixation to the bone and are fixed to the femoral and tibial implants using bone cement.
    Device Description

    The EMPOWR Revision Knee™ Symmetric TT (Trabecular Titanium) Cones are an optional accessory in primary or revision Total Knee Arthroplasty. The EMPOWR Symmetric TT Cones are sterile, single-use devices that are compatible for use with the EMPOWR Revision Knee™ components. The EMPOWR Symmetric TT Cones are composed of Ti6Al4V alloy (per ASTM F1472 and ISO 5832-3) and feature a porous Trabecular Titanium (TT) structure on the external surface of the implant. The EMPOWR Symmetric TT Cones are additively manufactured via Electron Beam Melting in the same manner as the reference AMF TT Cones device.

    AI/ML Overview

    This document is an FDA 510(k) clearance letter for a medical device: the EMPOWR Revision Knee™ (EMPOWR Revision Knee™ Symmetric TT Cones).

    It is crucial to understand that this document DOES NOT contain information about acceptance criteria or specific studies proving the device meets those criteria in the context of an AI/ML medical device.

    The 510(k) clearance process for this orthopedic implant relies on demonstrating substantial equivalence to a previously cleared predicate device, primarily through bench testing (mechanical performance) and, in some cases, clinical data if significant differences exist. This is a very different type of clearance than for AI/ML devices, which require performance data related to algorithmic accuracy or clinical utility.

    Therefore, I cannot extract the requested information (table of acceptance criteria, sample sizes for test/training sets, experts, adjudication, MRMC, standalone performance, ground truth establishment) because it is not present in this document.

    The document states:

    • "No animal data submitted."
    • "No clinical data submitted."
    • "All testing and evaluations demonstrate that the subject device is substantially equivalent to the primary predicate."

    The performance testing listed focuses on mechanical properties (Dynamic Fatigue Testing, MR Conditional Labeling), which are relevant for an orthopedic implant but entirely different from the performance metrics and study designs expected for an AI/ML diagnostic or assistive device.

    In summary, the provided document does not support a response to the prompt's specific questions regarding acceptance criteria and performance data for an AI/ML device.