Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K243356

    Validate with FDA (Live)

    Device Name
    Asiga DentaBASE
    Manufacturer
    Date Cleared
    2025-04-11

    (164 days)

    Product Code
    Regulation Number
    872.3760
    Panel
    Dental
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Asiga DentaBASE is intended exclusively for professional dental work.
    Asiga DentaBASE is a 3D print resin intended for the manufacturing of 3D printed denture bases.
    The denture bases produced are suitable for dental indications including removable dentures.

    Device Description

    Asiga DentaBASE resins are used with digital light processing (DLP) based 3D printers to produce denture bases. DentaBASE resin has been validated for use with the Asiga Max Series and Pro Series 3D printers.

    Asiga DentaBASE is a Type 4 light-cure methacrylate-based resin with photoinitiator, UV absorber, dispersant and pigments.

    Asiga DentaBASE resin material is used in a DLP 3D printer, which prints the denture base from CAD data. The denture base is built by solidifying successive layers of photopolymer against each other. Each layer is light cured before adding the next layer, with post-curing in a light chamber unit. The 3D printer and light-curing unit are not included with the device.

    The device is supplied as a pre-mixed resin in one color, natural pink. The device is supplied non-sterile, and it not intended to be sterilized.
    Asiga DentaBASE has a shelf life of 36 months.
    AsigaDentaBASE is compliant to ISO 20795-1 for Type 4 materials.
    AsigaDentaBASE is a surface device with mucosal membrane contact for >30 days and is compliant to ISO 10993-1 and ISO 7405.

    AI/ML Overview

    The provided FDA 510(k) clearance letter for Asiga DentaBASE does not contain information relevant to AI/ML device performance or clinical study details as described in the prompt's request. This is a clearance for a 3D printing resin for denture bases, which is a physical material, not an AI/ML diagnostic or assistive device.

    Therefore, I cannot provide the requested information regarding:

    • Acceptance criteria and reported device performance related to AI/ML metrics. The document refers to physical and chemical properties of the resin, not AI performance metrics like sensitivity, specificity, or AUC.
    • Sample size and data provenance for a test set.
    • Number and qualifications of experts for ground truth.
    • Adjudication method.
    • MRMC comparative effectiveness study.
    • Standalone algorithm performance.
    • Type of ground truth used (expert consensus, pathology, outcomes data, etc.).
    • Sample size for the training set.
    • How ground truth for the training set was established.

    The document primarily focuses on demonstrating substantial equivalence to a predicate device (NextDent Denture 3D+) and compliance with relevant ISO standards and FDA guidance for denture base resins (e.g., ISO 20795-1:2013 for Type 4 materials, ISO 10993-1:2018 for biocompatibility). The "tests" mentioned are bench tests for material properties (flexural strength, modulus, water sorption, solubility, residual monomer, biocompatibility), not performance evaluation of an AI algorithm.

    The only "performance criteria" mentioned are those for the physical resin as outlined in FDA guidance "Denture Base Resins – Performance Criteria for Safety and Performance Based Pathway (April 13, 2022)" and ISO 20795-1:2013.

    In summary, this document is about a material used in dentistry, not an AI product, so the requested AI-centric information is not present.