510(k) Data Aggregation

    K Number
    K233671

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-01-04

    (50 days)

    Product Code
    Regulation Number
    874.4680
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    aScope 5 Broncho is intended for endoscopic procedures and examination within the airways and tracheobronchial tree. aScope 5 Broncho is intended to provide visualization via a compatible Ambu displaying unit, and to allow passing of endotherapy instruments via its working channel.

    The Ambu® aView™ 2 Advance is intended to display live imaging data from compatible Ambu visualization devices.

    Device Description

    The Ambu® aScope™ 5 Broncho System is a combination of an endoscope, Ambu® a5cope™ 5 Broncho, and a compatible displaying unit, Ambu® aView™ 2 Advance.

    Ambu® aScope™ 5 Broncho is a sterile, single-use flexible bronchoscope designed to conduct endoscopic procedures and examination of the airways and tracheobronchial tree. The endoscope is available in two size configurations: Ambu® aScope™ 5 Broncho 4.2/2.2 and Ambu® aScope™ 5 Broncho 2.7/1.2. Apart from the size, the endoscopes share a similar design. The inserted into the patient airway through the mouth, nose, endotracheal tube, tracheostomy tube, etc. There is a working channel system within the endoscope for use with endotherapy instillation of fluids. An introducer (luer lock adaptor), which is supplied together with the endoscopes, can be attached to the working channel port during of blood, saliva, and mucus from airway is possible through the suction system. Ambu® aScope™ 5 Broncho features an integrated camera module with built-in dual LED illumination. The image module provides a cropped 400x400 pixels signal from the 160 Kpixel sensor.

    The Ambu® aView™ 2 Advance, also referred to as a displaying unit, is a non-sterile digital monitor intended to display live imaging data from Ambu visualization devices. The product consists of a 12.8" LCD screen. The device is powered through a Lithium-ion (Li-ion) battery or a separate power adapter.

    Ambu® aView™ 2 Advance displaying unit has the following physical and performance characteristics:

    • · Displays the image from the Ambu® aScope™ 5 Broncho endoscope on the screen.
    • · Can record snapshots or video of image from Ambu® aScope™ 5 Broncho endoscope.
    • · Can connect to an external monitor.
    • · Reusable device.
    AI/ML Overview

    No information regarding acceptance criteria or a study proving the device meets the acceptance criteria is provided in the document. The document is a 510(k) clearance letter from the FDA for a bronchoscope system. It primarily focuses on demonstrating substantial equivalence to predicate devices based on intended use, technological characteristics, and non-clinical performance testing.

    Therefore, I cannot provide a table of acceptance criteria, device performance, sample sizes, data provenance, expert qualifications, adjudication methods, MRMC study details, standalone performance, ground truth types, or training set information. The document merely confirms that the "Ambu® aScope™ 5 Broncho System performed as expected and met the test specifications set." but does not elaborate on these specifications or the studies performed.