Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K233637

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2024-06-28

    (228 days)

    Product Code
    Regulation Number
    870.1250
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Cordis BRITECROSS Support Catheters are indicated to guide and support a guide wire during access to the peripheral vasculature, allow for exchange of guide wires, and provide a conduit for the delivery of saline solutions or diagnostic contrast agents.

    Device Description

    The BRITECROSS Support Catheter is a flexible single lumen catheter that is intended to cross lesions to facilitate guidewire access and/or the delivery of saline/contrast during peripheral vascular interventions. The subject device is designed to allow for fluoroscopic visualization of the catheter. The radiopaque distal tip allows for accurate placement of the tip relative to the lesion. Further, there are two (2) radiopaque marker bands incorporated along the shaft to provide the clinician with a length reference facilitating approximation of the lesion length. On the proximal end, the hub has an integrated strain relief and a standard female luer to connect with a standard syringe. The BRITECROSS Catheter is available in various lengths and diameters and the size is printed on the hub for quick identification. The device is sterile and is for single use.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called the "Cordis BRITECROSS Support Catheter." This is a regulatory filing that aims to demonstrate that a new device is as safe and effective as an already legally marketed device (the predicate device).

    Crucially, this document focuses on the substantial equivalence of a new medical device to a predicate device based on performance testing and predicate device comparison, not on the evaluation of an AI/ML algorithm. The provided text does not contain information about an AI/ML device, its acceptance criteria, or a study proving that an AI/ML device meets those criteria.

    Therefore, I cannot fulfill your request to describe the acceptance criteria and the study that proves an AI/ML device meets the acceptance criteria using the provided text. The device described, the Cordis BRITECROSS Support Catheter, is a physical medical device (a catheter) and not an AI/ML algorithm.

    The "Performance Data" section lists various physical, mechanical, and biological tests conducted on the catheter (e.g., dimensional, mechanical, in-vitro testing, biocompatibility, sterilization), which are typical for physical medical devices to demonstrate their safety and efficacy. It explicitly states "No clinical data was required" and "No animal performance data was required," further indicating that this is not an AI/ML study.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1