510(k) Data Aggregation

    K Number
    K233527

    Validate with FDA (Live)

    Date Cleared
    2023-11-29

    (28 days)

    Product Code
    Regulation Number
    888.3050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Minuteman G5 MIS Fusion Plate is a posterior, non-pedicle fusion device, intended for use at a single interspace in the non-cervical spine (T1-S1). It is intended for plate fixation/attachment to spinous processes for the purpose of achieving instrumented posterior arthrodesis (i.e., fusion) in the following conditions:
    • Lumbar spinal stenosis;
    • degenerative disc disease (DDD) (defined as back pain with degeneration of the disc confirmed by history and radiographic studies); and/or
    • spondylolisthesis.
    The Minuteman G5 MIS Fusion Plate is intended for use with bone graft material. The device may be implanted via a lateral transverse approach (L1-S1) or a posterior approach (T1-S1).

    The Minuteman G1 (Posterior Fusion Plate) is a posterior, non-pedicle fusion device, intended for use at a single interspace in the non-cervical spine (T1-S1). It is intended for plate fixation/attachment to spinous processes for the purpose of achieving instrumented posterior arthrodesis (i.e., fusion) in the following conditions:
    • Lumbar spinal stenosis;
    • degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); and/or
    • spondylolisthesis.
    The Minuteman G1 (Posterior Fusion Plate) is intended for use with bone graft material. The device may be implanted via a lateral transverse approach (L1-S1) or a posterior approach (T1-S1).

    The HA Minuteman G3-R MIS Fusion Plate is a posterior, non-pedicle fusion device, intended for use at a single interspace in the noncervical spine (T1-S1). It is intended for plate fixation/attachment to spinous processes for the purpose of achieving instrumented posterior arthrodesis (i.e., fusion) in the following conditions:
    • Lumbar spinal stenosis;
    • degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); and/or
    • spondylolisthesis.
    The HA Minuteman G3-R MIS Fusion Plate is intended for use with bone graft may be implanted via a lateral transverse approach (L1-S1).

    The Minuteman G3/HA Minuteman G3 MIS Fusion Plate is a posterior, non-pedicle fusion device, intended for use at a single interspace in the non-cervical spine (T1-S1). It is intended for plate fixation/attachment to spinous processes for the purpose of achieving instrumented posterior arthrodesis (i.e., fusion) in the following conditions:
    • Lumbar spinal stenosis;
    • degenerative disc disease (DDD) (defined as back pain with degeneration of the disc confirmed by history and radiographic studies); and/or
    • spondylolisthesis.
    The Minuteman G3/HA Minuteman G3 MIS Fusion Plate is intended for use with bone graft material. The device may be implanted via a lateral transverse approach (L1-S1) or a posterior approach (T1-S1).

    Device Description

    The Minuteman MIS Fusion Plate Implants consist of bilateral Plates and a Body/Post that connects the Plate components include several gripping features for attachment of the spinous processes. The Minuteman MIS Fusion Plate Implants are available in multiple sizes to accommodate varying patient anatomy. The Minuteman MIS Fusion Plate Implants are made from Ti6A4V and Ti6A4V ELI. The HA versions of the Minuteman MS Fusion Plate Inplants have an additional hydroxyapatite coating on the distal regions of the device.

    AI/ML Overview

    This is a 510(k) premarket notification for a medical device called the Minuteman MIS Fusion Plate Implants. The submission aims to update the Indications for Use for existing devices, rather than introducing a new device or making significant technological changes. As such, the typical detailed studies and acceptance criteria related to device performance in terms of accuracy, sensitivity, or specificity are not applicable or required in this document.

    The document explicitly states:
    "Non-Clinical and/or Clinical Tests were not performed as part of this submission. The Minuteman MIS Fusion Plate Implants with the updated Indications for Use are substantially equivalent to the previously cleared predicate devices."

    Therefore, I cannot provide information on acceptance criteria or studies as requested in your prompt because this type of information is generally not included in a 510(k) submission focused solely on updating the indications for use of an already cleared device, especially when no technological or performance changes have been made. The "acceptance criteria" here refer to the FDA's determination that the updated indications do not alter the substantial equivalence to previously cleared devices.

    Instead, the documentation focuses on demonstrating substantial equivalence to predicate devices (K221023 Minuteman MIS Fusion Plate Implants) based on:

    • Same technological characteristics: "same design, packaging, principles of operations"
    • No new intended use: "The modifications to the Indications for Use statement do not affect the safety and effectiveness of the Minuteman MIS Fusion Plate Implants."

    There are no details on software, AI, or specific performance metrics that would necessitate the information you requested about human readers, ground truth establishment, or test set characteristics.