Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K222977

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2023-02-17

    (142 days)

    Product Code
    Regulation Number
    892.5050
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    DSPS-Prominent™ Masks, DSPS-Prominent™ Baseplate, MR:

    Positioning and immobilization of the patient during radiotherapy. This includes positioning and immobilization of the patient during image acquisition to support treatment such as in Magnetic Resonance (MR) and Computed Tomography (CT) Imaging Systems.

    CouchStrip:

    Positioning of the patient during radiotherapy and radio diagnostics, including MR where indicated.

    Device Description

    DSPS-Prominent Masks: The DSPS-Prominent Masks are facial and occipital thermoplastic masks which are used as part of the DSPS-Prominent system to facilitate accurate positioning and immobilization of the head, neck and shoulder region of the patient.

    DSPS-Prominent™ Baseplate, MR: The DSPS-Prominent baseplate, MR is an MR Safe baseplate which supports the positioning and immobilization of the patient within DSPS-Prominent occipital and facial masks. The device features a cantilevered frame on the cranial side which facilitates the use of both facial and occipital head, neck and shoulder masks. The device is fixed to the couch using couch strips.

    CouchStrip: CouchStrips are bars which connect the patient positioning device onto the treatment table at indexed positions. The DSPS-Prominent CouchStrip is MR Safe.

    AI/ML Overview

    This document describes a 510(k) premarket notification for patient positioning devices (DSPS-Prominent™ Masks, DSPS-Prominent™ Baseplate, MR, CouchStrip). This submission is for medical devices, specifically for radiotherapy positioning and immobilization, not an AI/ML device. Therefore, the requested information regarding acceptance criteria, study details for AI/ML performance (e.g., sample size, data provenance, expert ground truth, MRMC studies, standalone performance, training set details) is not applicable.

    The document focuses on demonstrating substantial equivalence to predicate devices based on design, materials, intended use, and functionality, rather than presenting performance metrics against specific acceptance criteria for an AI algorithm.

    The "Testing Performed" section broadly states:

    • "Clinical and non-clinical testing was performed."
    • "Non-clinical performance testing was completed to ensure that the devices fulfilled the defined requirements."
    • "Clinical testing was performed to ensure that the use of the devices enables submillimetre positional accuracy to be achieved."
    • "The testing confirmed that the new devices are as safe and effective as the predicate devices."

    However, specific acceptance criteria and detailed quantitative results from these tests are not provided in this summary.

    Therefore, I cannot provide a table of acceptance criteria and reported device performance or answer the specific questions related to AI/ML study design, as this information is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1