Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K221135

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2022-05-19

    (30 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The X-Twist PEEK Suture Anchors are indicated for attachment of soft tissue to bone. These products are intended for the following indications:

    Shoulder: Rotator Cuff Repair, Acromioclavicular Separation Repair, Biceps Tenodesis, Capsular Shift or Capsulolabral Reconstruction, Deltoid Repair, SLAP Lesion Repair.

    Knee: Medial Collateral Ligament Repair, Lateral Collateral Ligament Repair, Posterior Oblique Ligament Repair, Extra Capsular Reconstruction, Iliotibial Band Tenodesis, Patellar Ligament and Tendon Avulsion Repair.

    Foot/Ankle: Lateral Stabilization, Medial Stabilization, Midfoot Reconstruction, Achilles Tendon Repair, Hallux Valgus Reconstruction, Metatarsal Ligament Repair.

    Elbow: Tennis Elbow Repair, Biceps Tendon Reattachment.

    Hand/Wrist: Scapholunate Ligament Reconstruction, Ulnar or Radial Collateral Ligament Reconstruction, TFCC.

    Device Description

    The X-Twist PEEK Suture Anchor consists of an implantable anchor and anchor tip that are provided assembled to a driver. Retention suture(s) or suture tapes(s) are preloaded through the driver cannulation to secure the anchor tip onto the driver shaft. The anchor tip can be loaded with additional suture(s) or suture tapes(s) if needed for the intended surgical procedure. Clockwise rotation of the driver allows for advancement of the fully threaded anchor and anchor tip into the prepared bone socket to serve as the point of fixation for soft tissue repair.

    AI/ML Overview

    Here's a breakdown of the acceptance criteria and the study that proves the device meets them, based on the provided text:

    Device: X-Twist PEEK Suture Anchor

    Type of Study: Non-clinical (benchtop) testing and bacterial endotoxin testing. No clinical study was performed.


    1. Table of Acceptance Criteria and Reported Device Performance

    TestAcceptance CriteriaReported Device Performance
    Benchtop TestingMet defined acceptance criteria, demonstrated substantial equivalency for design and performance when assessed against predicate devices.The results of the testing met the defined acceptance criteria and were assessed against the results obtained with the predicate devices to determine substantial equivalency for design and performance. (Specific numerical values not provided in the summary)
    - Cycle loading and elongationNot explicitly defined in this section, but implied to be comparable to predicate.Met defined acceptance criteria.
    - Insertion torqueNot explicitly defined in this section, but implied to be comparable to predicate.Met defined acceptance criteria.
    - Anchor pullout forceNot explicitly defined in this section, but implied to be comparable to predicate.Met defined acceptance criteria.
    Bacterial Endotoxin Testing (USP <85>)Standard Curve Correlation Coefficient: ≥0.98 Neg. Control Onset Time: Onset time > lowest Cal Standard PPC: 50-200% Test Article Endotoxin Concentration: ≤20 EU/deviceStandard Curve Correlation Coefficient: 1.00 Neg. Control Onset Time: >6000 seconds PPC: 58% Test Article Endotoxin Concentration: <1 EU/device

    2. Sample Size Used for the Test Set and Data Provenance

    • Benchtop Testing: The sample size for benchtop tests (cycle loading, elongation, insertion torque, pullout force) is not specified in the provided summary.
    • Bacterial Endotoxin Testing:
      • Sample Size: Ten (10) disassembled devices were used as test articles.
      • Data Provenance: The origin of the devices or components is not stated. This is laboratory-based, non-clinical data.

    3. Number of Experts Used to Establish Ground Truth and Qualifications

    • Not applicable. This study is a non-clinical, benchtop and laboratory testing evaluation for mechanical performance and bacterial endotoxin levels. It does not involve expert interpretation or ground truth establishment in the traditional sense of clinical or diagnostic studies. The "ground truth" for these tests is based on established engineering principles and medical device standards (e.g., USP <85> and <161>).

    4. Adjudication Method for the Test Set

    • Not applicable. As this is non-clinical benchtop and laboratory testing, there is no adjudication method involving human interpretation to establish ground truth for a test set. The results are quantitative measurements against predefined criteria.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    • No. An MRMC comparative effectiveness study was not done. The submission explicitly states: "Clinical testing was deemed not necessary for demonstrating substantial equivalence to the predicate devices."

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    • Not applicable. This device is a physical medical implant (suture anchor), not an algorithm or AI-powered system, so the concept of "standalone performance" in the context of AI does not apply. The performance evaluated is the physical and biological characteristics of the device itself.

    7. Type of Ground Truth Used

    • Benchtop Testing: Engineering performance metrics (e.g., force, torque, elongation) compared against established design specifications and predicate device performance.
    • Bacterial Endotoxin Testing: Quantitative measurement of endotoxin levels against a regulatory standard (USP <85> and <161>).

    8. Sample Size for the Training Set

    • Not applicable. This is a physical medical device. The concept of a "training set" typically applies to machine learning algorithms. While the device's design might have involved iterative testing and refinement, this is not documented as a formal "training set" in the context of this submission. The "training" in a broad sense would be the development process and previous predicate device data.

    9. How the Ground Truth for the Training Set Was Established

    • Not applicable. As no formal "training set" (in the AI/ML sense) was used, this question is not relevant. The "ground truth" for the device's development would likely be established through biomechanical principles, material science, and the performance characteristics of previously cleared predicate devices.
    Ask a Question

    Ask a specific question about this device

    Page 1 of 1