510(k) Data Aggregation

    K Number
    K212405

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2021-09-30

    (59 days)

    Product Code
    Regulation Number
    888.3060
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The EMERGE™ Anterior Cervical Plate System is intended for anterior screw fixation to the cervical spine (C2-C7) for the following indications: degenerative disc disease (DDD) (defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumors (primary and metastatic), deformity (kyphosis, lordosis), failed previous fusions (pseudarthrosis), spondylolisthesis, and spinal stenosis. The EMERGE™ Anterior Cervical Plate System is not intended for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine.

    Device Description

    The EMERGE™ Anterior Cervical Plate System consists of cervical plates offered in various sizes to accommodate a variety of spinal levels based on surgical need and anatomic requirements. The plate attaches to the anterior portion of the vertebral body of the cervical spine. The plates can be used with fixed angle or variable angle screws. The system is comprised of a Titanium Alloy (Ti-6Al-4V ELI) plates and bone screws.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the EMERGE™ Anterior Cervical Plate System, a spinal intervertebral body fixation orthosis. The document focuses on demonstrating substantial equivalence to a legally marketed predicate device based on indications, design, materials, function, manufacturing, and performance.

    However, the document does not contain any information about an AI/ML-based device, nor does it mention any studies involving acceptance criteria and performance metrics for such a device. The device described is a physical medical implant (a cervical plate system) designed for surgical use. Therefore, it's not possible to answer your specific questions relating to AI/ML device performance, ground truth, expert adjudication, or MRMC studies from the provided text.

    The closest relevant information is contained in the "Performance Data" section on page 5, which states:

    "Testing on the EMERGE™ Anterior Cervical Plate System included static compression, static torsion, and dynamic compression per ASTM F1717. The results demonstrate that the EMERGE™ Anterior Cervical Plate is substantially equivalent to the performance criteria identified in Spinal Plating Systems -Performance Criteria for Safety and Performance Based Pathway Guidance document; FDA-2019-D-1647."

    This indicates that the performance of the physical device was evaluated against established engineering standards (ASTM F1717) and FDA guidance for spinal plating systems. However, these are mechanical and material performance tests, not AI/ML model performance evaluations.