Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K202706

    Validate with FDA (Live)

    Date Cleared
    2020-12-31

    (106 days)

    Product Code
    Regulation Number
    878.4040
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Surgical gowns are intended to be worn by operating room personnel during surgical procedure to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. Per ANSI/AAMI PB70:2012 Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities, the surgical gowns met the requirements for Level 3 classification.

    Device Description

    The proposed devices are intended to be worn by operating room personnel during surgical procedures to protect both the surgical patient and the operating room personnel from transfer of microorganisms, body fluids, and particulate material. The proposed devices are single use, disposable medical devices and can be provided in sterile and non-sterile two types. Both the sterile and non-sterile surgical gowns are available in six sizes, including S, M, L, XL, XXL and XXXL. For non-sterile surgical gowns, they shall be sterilized by EO prior to use. Per ANSI/AAMI PB70:2012 Liquid barrier performance and classification of protective apparel and drapes intended for use in health care facilities, the proposed devices meet the requirements for Level 3 classification.

    AI/ML Overview

    This document is a 510(k) Summary for a Surgical Gown (Sterile) and Surgical Gown (Non-sterile). It describes the device, its intended use, and a comparison to predicate devices, focusing on non-clinical testing to demonstrate substantial equivalence.

    Here's a breakdown of the requested information based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document provides a "Technological Characteristic Comparison Table" (Table 2) that lists various performance criteria and the performance of the Subject Device (K202706). It implies that the acceptance criteria are met if the device's performance is similar to or meets the standards of the predicate devices or specified test methods.

    ItemAcceptance Criteria (Implied)Reported Device Performance (Subject Device K202706)
    Weight per square (g)Similar to predicate (e.g., 50g/m², 45g/m², 68g/m² or 44g/m²)55g/m²
    SizeSimilar to predicate (e.g., M, L, XL, XXL, XXXL, XXXL-XLONG or XL)S, M, L, XL, XXL, XXXL
    FlammabilityClass I (as per 16 CFR Part 1610)Class I
    Hydrostatic pressure>50 cm (as per AATCC 127:2017)>50 cm
    Water impact≤1.0 g (as per AATCC 42:2017)≤1.0 g
    Breaking strength>20N (as per ASTM D5034:2017)>20N
    Tearing strength>20N (as per ASTM D5587:2019)>20N
    LintingLog10<4 (as per ISO 9073-10:2003)Log10<4
    Air permeability>15cm³/s/cm² (29 ft³/min/ft²) or >30 ft³/min/ft² (as per ASTM D737:2018)>30 ft³/min/ft²
    MaterialSimilar to SMS polypropylene nonwovenSMS polypropylene nonwoven + Polyester
    LevelLevel 3 per AAMI PB 70Level 3 per AAMI PB 70
    Biocompatibility: CytotoxicityNo Cytotoxicity (as per ISO 10993-5:2009)No Cytotoxicity
    Biocompatibility: IrritationNo Irritation (as per ISO 10993-10:2010)No Irritation
    Biocompatibility: SensitizationNo Sensitization (as per ISO 10993-10:2010)No Sensitization
    SterileSterile/Non-sterileSterile/Non-sterile
    Seal Strength(Not explicitly stated in table, but ASTM F88/F88M:2015 implies a criterion)(Test performed, results not explicitly shown in table)
    Seal Leaks(Not explicitly stated in table, but ASTM F1929:2015 implies a criterion)(Test performed, results not explicitly shown in table)
    EO Sterilization Residuals(Not explicitly stated in table, but ISO 10993-7:2008 implies a criterion)(Test performed, results not explicitly shown in table)

    2. Sample size used for the test set and the data provenance (e.g. country of origin of the data, retrospective or prospective)

    The document does not specify the sample sizes used for each non-clinical test or the provenance of the data (e.g., country of origin, retrospective/prospective). It only states that "Non clinical tests were conducted to verify that the proposed device met all design specifications as was similar to the predicate device."

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts (e.g. radiologist with 10 years of experience)

    This section is not applicable. The study involved non-clinical performance testing of a medical device (surgical gown), not studies requiring expert interpretation or ground truth establishment in a medical context.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This section is not applicable. Adjudication methods are typically used in clinical studies involving human interpretation or subjective assessment.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This section is not applicable. No clinical studies, MRMC studies, or AI components are mentioned in this 510(k) summary.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This section is not applicable. The device is a surgical gown; it does not involve an algorithm or AI.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc.)

    The "ground truth" for the non-clinical tests were established by the performance specifications outlined in recognized standards such as ANSI/AAMI PB70:2012, 16 CFR Part 1610, AATCC 127:2017, AATCC 42:2017, ISO 9073-10:2003, ASTM D1683/D1683M:2017/(R)2018, ASTM D5587:2019, ASTM D5034:2017, ASTM D737:2018, ASTM F88/F88M:2015, ASTM F1929:2015, ISO 10993-7:2008, ISO 10993-5:2009, and ISO 10993-10:2010.

    8. The sample size for the training set

    This section is not applicable. There is no mention of a "training set" as this is a non-clinical device performance study, not a machine learning or AI-based study.

    9. How the ground truth for the training set was established

    This section is not applicable. As there is no training set for this type of device submission.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1