Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K202666

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2020-10-14

    (30 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CONSTRUX® Mini PTC Spacer System is indicated for spinal fusion procedures at one or two contiguous levels within the cervical spine (C2-T1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies.

    The CONSTRUX Mini PTC Spacer System is intended for use with autograft and/or allograft comprised of cancellous and/or corticocancellous bone graft and supplemental fixation system; the hyperlordotic implants (≥10°) are required to be used with an anterior cervical plate.

    Patients must have undergone a regimen of at least six weeks of non-operative treatment prior to being treated with the CONSTRUX Mini PTC Spacer System in the cervical spine.

    Device Description

    The CONSTRUX Mini PTC Spacer System is comprised of a variety of implants that has a PEEK core (conforming to ASTM F2026) with integrated porous Titanium alloy (Ti-6Al-4V) endplates (conforming to ASTM F1580). The implant superior and inferior Titanium plate surface provides increased stability for the implant. The titanium endplates have open macroscopic 3D pores with a microscopic roughened surface and nano-scale features. The CONSTRUX Mini PTC spacer is implanted in the cervical intervertebral disc space and is intended to facilitate vertebral fusion by stabilizing adjacent vertebrae, maintaining disc height, and preventing the collapsing of one vertebrate onto another.

    The CONSTRUX Mini PTC Spacer System is not intended to be used as a standalone device. The CONSTRUX Mini PTC Spacer System must be used with a supplemental fixation system. The CONSTRUX Mini PTC Spacer System implants are provided sterile.

    AI/ML Overview

    This document is an FDA 510(k) clearance letter for a medical device called the "CONSTRUX® Mini PTC Spacer System." It is a regulatory approval document and does not contain information about the acceptance criteria or a study proving the device meets those criteria from an AI/performance perspective.

    The "Performance Testing Summary" explicitly states: "No new mechanical testing was performed for the CONSTRUX Mini PTC Spacer System because the 10° lordosis does not create a new worst case construct for mechanical performance."

    Therefore, based solely on the provided text, I cannot answer the questions about acceptance criteria for device performance, especially those related to AI or clinical study performance. The document focuses on establishing substantial equivalence to existing predicate devices based on design, materials, and intended use, rather than presenting a performance study against specific acceptance criteria.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1