Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K153731

    Validate with FDA (Live)

    Date Cleared
    2016-08-25

    (241 days)

    Product Code
    Regulation Number
    880.5440
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The LifeFlow™ Rapid Infusion Device is an intravenous administration set with Handle intended for rapid* delivery of fluids from a container into a patient's vascular system. The device is intended to deliver only crystalloid and colloid resuscitative fluids. These devices may be used for any pediation with consideration with consideration given to adequacy of vascular anatomy, appropriateness for the solution being infused and duration of therapy.

    *Capable of rates greater than 150 mL/min through a 20G needle.

    Device Description

    Each LifeFlow™ Rapid Infusion Device (LifeFlow™ Device) is a disposable, single-use device that includes an intravenous administration set (Tubing Set) and a Handle and is used to deliver up to 4 Liters of fluid from a container into a patient's vascular system rapidly through manual compression of the levered Handle.

    The Tubing Set is sterile, compatible with standard IVs and IV fluid bags and comprised of various generic components, such as a check valve, tubing, syringe, bag spike, thumb clamp, Luer access device, and Luer connections. Each of the needleless components are 510(k) cleared.

    The addition of a hand pressure pump, the Handle, provides the capability for rapidly delivering IV fluids. The end of the Tubing Set is placed into the Handle. The clear canopy, through which the graduations and contents of the syringe can be viewed during use, is closed. The Handle is manually compressed to actuate the syringe, which delivers fluid to the patient and then automatically refills when the Handle is released.

    AI/ML Overview

    The provided text is a 510(k) summary for the LifeFlow™ Rapid Infusion Device and discusses its substantial equivalence to a predicate device. It does not describe an AI/ML powered device, nor does it contain the information required to analyze acceptance criteria and studies in the context of AI device performance.

    Therefore, I cannot provide an answer based on the given sections of the document. The document pertains to a medical device's 510(k) submission, confirming its equivalence to a predicate device based on functional, biocompatibility, and sterilization testing, not AI/ML performance evaluation.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1