Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K152315

    Validate with FDA (Live)

    Date Cleared
    2015-10-28

    (72 days)

    Product Code
    Regulation Number
    888.3520
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Unicompartmental knee implants are indicated for restoring either compartment of a knee that has been affected by the following:

    • Noninflammatory degenerative joint disease including osteoarthritis, traumatic arthritis, or avascular necrosis;
    • Correction of functional deformity:
    • Revision procedures where other treatments or devices have failed; and
    • Treatment of fractures that are unmanageable using other techniques.

    Unicompartmental knee implants are single use only and are intended for implantation only with bone cement.

    Device Description

    The Journey II Uni tibial baseplate and inserts are modifications of the existing Journey Uni tibial baseplate and inserts that were previously cleared for market via K102069 (baseplates) and K061011 (inserts). The subject of this premarket notification are modifications to the insert locking mechanism on the tibial baseplate and insert, articular surface geometry, sizing of baseplate and inserts, and characteristics of the cemented surface of the baseplate. Additional device specific instruments are also included as part of the submission.

    The Journey II Uni inserts are available in left medial/right lateral and right medial/left lateral cross-linked polyethylene articular inserts and titanium alloy (Ti-6Al-4V) tibial bases which will be available in left medial/right lateral and right medial/left lateral.

    The Journey II Uni tibial baseplate and inserts will use existing Journey Uni femoral components cleared via K081351 or GENESIS Uni femoral components cleared via K912735.

    AI/ML Overview

    This document pertains to the clearance of a medical device, specifically the Journey II Uni Tibial Base and Insert, a unicompartmental knee implant. The information provided outlines the reasoning for its substantial equivalence to previously cleared devices rather than a study designed to meet specific acceptance criteria for a novel device. Therefore, many of the requested fields regarding acceptance criteria and study details are not directly applicable in the context of this 510(k) submission.

    Here's an analysis based on the provided text:

    1. A table of acceptance criteria and the reported device performance

    The document does not present specific acceptance criteria in the form of quantitative thresholds for device performance. Instead, it relies on demonstrating substantial equivalence to predicate devices through mechanical testing and design similarities. The "performance" reported is that the device is equivalent to existing, legally marketed predicate devices.

    Acceptance Criteria (Implied)Reported Device Performance
    Mechanical equivalence to predicate devices"A review of the results indicates that the Journey II Uni tibial baseplate and inserts are equivalent to the existing, legally marketed predicate devices with regards to mechanical performance."
    No new issues related to safety and effectiveness"and that there are no new issues related to the safety and effectiveness of the subject device(s)."

    2. Sample sized used for the test set and the data provenance

    • Sample Size: The document lists types of mechanical tests performed (Unsupported Baseplate Fatigue Testing, Static testing of the insert locking mechanism, Fully Supported Fatigue/Cement Adhesion Testing, Contact Area Analysis). However, it does not specify the sample sizes used for these tests.
    • Data Provenance: The data is generated from mechanical verification testing/analysis conducted by Smith & Nephew, Inc. It is not clinical data, nor is its country of origin or retrospective/prospective nature specified, as these are mechanical tests, not human studies.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    This section is not applicable. The ground truth for mechanical testing is based on engineering principles and established testing standards, not expert consensus as in diagnostic accuracy studies.

    4. Adjudication method (e.g. 2+1, 3+1, none) for the test set

    This section is not applicable as there is no human interpretation or adjudication involved in the mechanical tests described.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    This section is not applicable. This submission is for a knee implant, not an AI-powered diagnostic device. No MRMC study was conducted.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    This section is not applicable. This is not an algorithm or software device.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    The "ground truth" for the assessment of this device is its mechanical performance relative to established predicate devices, as determined by engineering tests and analyses, adhering to relevant standards for medical device design and manufacturing.

    8. The sample size for the training set

    This section is not applicable. This is not a machine learning or AI device that requires a training set.

    9. How the ground truth for the training set was established

    This section is not applicable. No training set was used.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1