510(k) Data Aggregation

    K Number
    K152262

    Validate with FDA (Live)

    Date Cleared
    2016-03-08

    (210 days)

    Product Code
    Regulation Number
    888.3040
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Ventix Knotless Anchor is indicated for use in soft tissue reattachment procedures in the shoulder, wrist/hand, ankle/ foot, elbow, and knee. Specific indications as follows:

    Shoulder - Bankart repair, SLAP repair, acromio-clavicular separation, rotator cuff repair or capsulolabral reconstruction, biceps tenodesis, and deltoid repair.

    Wrist/Hand - Scapholunate ligament reconstruction and ulnar/radial collateral ligament reconstruction.

    Ankle/Foot - Lateral stabilization, medial stabilization, Achilles tendon repair/reconstruction, hallux valgus reconstruction, and mid- and forefoot reconstruction.

    Elbow - Ulnar or radial collateral ligament reconstruction, biceps tendon reconstruction, and lateral epicondylitis repair

    Knee - Medial collateral ligament repair, lateral ligament repair, posterior oblique ligament repair, joint capsule closure, iliotibial band tenodesis, patellar ligament/tendon repair, patellar realignment and repair, and Vastus Medialis Obliquus (VMO) Muscle Advancement.

    The Ventix Knotless anchors are also indicated for supplementary fixation when used in conjunction with a primary fixation device in ACL repair and reconstruction surgical procedures requiring graft fixation.

    Device Description

    The Ventix anchor is a two-piece design featuring a winged tip that fits into the anchor body. The anchor body is vented. The Ventix anchors will be offered in two sizes: 4.75mm and 5.5mm and is manufactured from polyetheretherketone (PEEK). The Ventix anchor will be loaded onto a disposable inserter.

    AI/ML Overview

    The provided text is a 510(k) premarket notification for the Ventix Knotless Anchors. It does not contain information about acceptance criteria, device performance tables, sample sizes, expert ground truth establishment, adjudication methods, MRMC studies, standalone algorithm performance, or training set details that would be relevant to an AI/ML medical device.

    The document describes a mechanical medical device (surgical anchors) and its substantial equivalence to a predicate device. The performance data discussed is related to the pull-out strength of the anchor, which is a biomechanical characteristic, not an AI/ML performance metric.

    Therefore, I cannot fulfill your request for information regarding acceptance criteria and studies related to an AI/ML device based on the provided text. The information you are asking for is typically found in FDA submissions for AI/ML-powered software as a medical device (SaMD) or AI-augmented medical devices.