Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K152131

    Validate with FDA (Live)

    Date Cleared
    2015-09-17

    (48 days)

    Product Code
    Regulation Number
    888.3070
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The RELIANCE Spinal Screw System is a pedicle screw systems intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar, and sacral spine: degenerative spondylolisthesis with objective evidence of neurological impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, and failed previous fusion (pseudarthrosis).

    The RELIANCE Spinal Screw System is also indicated for pedicle screw fixation for the treatment of severe degenerative spondylolisthesis (Grades 3 and 4) of the L5-S1 vertebra in skeletally-mature patients receiving fusion by autogenous bone graft and having implants attached to the lumbar and sacral spine (L3 to sacrum) with removal of the implants after the attainment of a solid fusion.

    When used posteriorly, the RELIANCE Spinal Screw System is also a hook and sacral/iliac screw fixation system of the noncervical spine indicated for: degenerative spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis, lordosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis). Levels of fixation are for the thoracic, lumbar and sacral spine.

    The RELIANCE Spinal Screw System, when used with staples and two rods as an anterior thoracic/lumbar screw fixation system, is indicated for spondylolisthesis, trauma (fracture and/or dislocation), spinal stenosis, deformities (scoliosis and/or kyphosis), tumor, and previous failed fusion (pseudarthrosis).

    When used in a percutaneous, posterior approach with MIS instrumentation, the RELIANCE Spinal Screw System components are intended for noncervical pedicle fixation and nonpedicle fixation for the following indications: degenerative spondylolisthesis, trauma (i.e., fracture or dislocation), spinal stenosis, curvatures (i.e., scoliosis, kyphosis, and/or lordosis), tumor, pseudarthrosis, and failed previous fusion in skeletally-mature patients.

    Device Description

    The Posterior RELIANCE Spinal Screw System consists of longitudinal rods, monoaxial screws, polyaxial screws, reduction screws, cannulated polyaxial screws, cannulated reduction screws, hooks, reduction hooks, set screws and transverse connectors. The Anterior RELIANCE Spinal Screw System consists of two spinal rods, monoaxial screws, staples, and set screws. The Anterior RELIANCE staples and screws are intended to be attached to the lateral aspect of the vertebral bodies from T5 to L4, and SHOULD NOT be attached to the anterior aspect. Furthermore, only Titanium components should be used anteriorly.

    The RELIANCE Spinal Screw System components are available in titanium alloy conforming to ASTM F-136 specifications as well as stainless steel conforming to ASTM F-138 specifications. Furthermore, various rods of the RELIANCE Spinal Screw System are available in Cobalt-Chrome conforming to ASTM F-75 and ASTM F-1537 specifications. Components of the differing diameter rod systems are NOT interchangeable. The components of one material should not be used with components of another material with the exception that the Cobalt-Chrome rods may be used with titanium alloy implants. The extension tabs on the reduction screw and hook components are intended to be removed intraoperatively.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for a medical device called the "Reliance Spinal Screw System." This notification primarily focuses on establishing substantial equivalence to existing predicate devices based on material, intended use, size range, and strength. It also mentions non-clinical testing performed according to ASTM standards.

    However, the document does not contain the information requested regarding acceptance criteria and a study proving the device meets those criteria, as typically seen in detail for AI/software-driven medical devices. The Reliance Spinal Screw System is a physical orthopedic implant, not an AI/software device, and thus the type of information requested (e.g., sample sizes for test sets, expert ground truth, MRMC studies, standalone algorithm performance) is not applicable or present in this regulatory submission.

    Specifically, the document lacks details on:

    1. Acceptance criteria and reported device performance (in a table): The document states the device underwent "Non-Clinical Testing including Static Compressive, Static Torsion, and Dynamic Compressive in accordance with ASTM F1717," but it does not provide the specific acceptance criteria or the reported performance data from these tests.
    2. Sample sizes for test set and data provenance: Not applicable in the context of an orthopedic implant device.
    3. Number of experts and their qualifications for ground truth: Not applicable.
    4. Adjudication method: Not applicable.
    5. MRMC comparative effectiveness study and effect size: Not applicable as this is not an AI-assisted diagnostic device.
    6. Standalone algorithm performance: Not applicable.
    7. Type of ground truth used: Not applicable.
    8. Training set sample size: Not applicable.
    9. How ground truth for training set was established: Not applicable.

    The core of this 510(k) submission is to demonstrate that the expanded Reliance Spinal Screw System (with new screw types and rods) is substantially equivalent to previously cleared versions and other predicate devices, primarily through comparison of its physical characteristics, materials, indications for use, and a statement of compliance with mechanical testing standards (ASTM F1717). The results of these mechanical tests are not detailed in this publicly available summary.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1