Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K131157

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2013-10-22

    (181 days)

    Product Code
    Regulation Number
    876.1075
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Ranfac Bone Marrow Aspiration Needle is intended for use in aspirating bone marrow.

    Device Description

    The Ranfac Bone Marrow Aspiration Needle is a single-use aspiration needle comprised of a stainless steel cannula with a molded plastic handle, and a stainless steel stylet with a molded plastic handle which mates with the cannula handle when the stylet is inserted through the cannula. While holding the mated handles, the user rotates the needle using a clockwise-counter clockwise motion while applying pressure on the bone. The needle bores into the marrow cavity. Once there the stylet is removed and aspiration is accomplished by attaching a luer syringe (not included) to the needle and applying negative pressure.

    AI/ML Overview

    The provided text describes a 510(k) summary for the Ranfac Bone Marrow Aspiration Needle, which is a medical device. This type of submission focuses on demonstrating substantial equivalence to a legally marketed predicate device rather than proving novel effectiveness or meeting specific performance criteria through a new clinical study. Therefore, much of the requested information regarding acceptance criteria, specific study designs (like MRMC or standalone performance), sample sizes, and ground truth establishment is not part of this 510(k) submission.

    The document explicitly states: "Clinical Data: Not applicable" (page 3). This means no clinical study was conducted to demonstrate the device's performance against specific acceptance criteria. Instead, the submission relies on non-clinical data and comparison to predicate devices.

    Here's an attempt to answer the questions based only on the provided text, highlighting where information is not available:

    1. A table of acceptance criteria and the reported device performance

    Since no clinical study was conducted for this 510(k) submission, there are no specific performance-based acceptance criteria or reported device performance metrics in the traditional sense of a clinical trial. The "acceptance criteria" for a 510(k) submission are typically related to demonstrating substantial equivalence to a predicate device in terms of intended use, technological characteristics, and safety.

    The summary focuses on conformance to recognized standards for materials, luer lock connections, and sterilization.

    Acceptance Criteria (Standards Conformance)Reported Device Performance (Claimed Conformance)
    Material: ISO 9626 (Stainless steel needle tubing)In conformance with ISO 9626
    Luer Lock (General): ISO 594/1 (Conical fittings)In conformance with ISO 594/1
    Luer Lock (Lock fittings): ISO 594-2 (Lock fittings)In conformance with ISO 594-2
    Sterilization: ISO 11135-1 (Ethylene Oxide)Applies to the sterilization of the finished device
    Sterilization Residuals: ISO 10993-7 (Ethylene oxide)Applies to the sterilization of the finished device
    Biological Indicators: AAMI/ANSI/ISO 14161 (Guidance)Applies to the sterilization of the finished device
    Packaging: ISO 11607-1 (Terminally sterilized medical devices)Applies to the sterilization of the finished device

    2. Sample size used for the test set and the data provenance

    Not applicable. No clinical test set data is provided in this 510(k) summary (as explicitly stated by "Clinical Data: Not applicable").

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. No clinical test set and thus no ground truth established by experts is mentioned in this 510(k) summary.

    4. Adjudication method for the test set

    Not applicable. No clinical test set is mentioned in this 510(k) summary.

    5. If a multi reader multi case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is a bone marrow aspiration needle, not an AI-assisted diagnostic tool. No MRMC study was conducted or mentioned.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is a bone marrow aspiration needle, not an algorithm or AI system.

    7. The type of ground truth used (expert consensus, pathology, outcomes data, etc)

    Not applicable. As "Clinical Data: Not applicable" is stated, no ground truth from a clinical study is provided. The basis for clearance is substantial equivalence to predicate devices, supported by non-clinical conformance to standards and material/design comparisons.

    8. The sample size for the training set

    Not applicable. This device is not an AI-driven system requiring a training set.

    9. How the ground truth for the training set was established

    Not applicable. This device is not an AI-driven system requiring a training set or associated ground truth.

    In summary: The provided 510(k) summary for the Ranfac Bone Marrow Aspiration Needle demonstrates substantial equivalence to predicate devices primarily through comparison of materials, design, principles of function, biocompatibility, and sterilization methods, along with conformance to relevant industry standards for medical device components and manufacturing processes. It explicitly states that clinical data is "Not applicable" for this submission.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1