Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K130944

    Validate with FDA (Live)

    Date Cleared
    2013-06-07

    (64 days)

    Product Code
    Regulation Number
    892.1560
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    iSR'obot Mona Lisa is intended for use by a trained urologist or physician to perform the computerassisted transperineal prostate biopsy under transrectal ultrasound guidance. The device serves as a biopsy needle guide only. It shall be used in conjunction with a third party ultrasound machine and endorectal probe that supports BMode, and a third party prostate biopsy gun and needle. The insertion of biopsy needle will be done by urologist.

    Device Description

    iSR'obot Mona Lisa is a platform-hosted motorized device integrating a probe-driving system for 3-D image collection and a precise biopsy guidance mechanism (biopsy needle platform) to control the orientation of needle insertion and depth of puncture to assist the surgeon perform targeted transperineal prostate biopsy in conjunction with the guidance of transrectal ultrasound. The device serves as a needle quide only.

    The device has a graphics user interface (GUI) that can provide a complete view of the 3D prostate to the physicians by hands-free image acquisition. The prostate segmentation tool allows a manual or automatic surface detection from the 3D image, based on which the prostate volume is calculated and the systematic biopsy plan is generated. This plan can be customized and the approved plan will be used to control the biopsy needle platform to guide the needle positioning for the manual puncture.

    AI/ML Overview

    The provided text is a 510(k) summary for the iSR'obot Mona Lisa device. It describes the device, its intended use, and substantial equivalence to a predicate device. However, it explicitly states:

    "Clinical Performance: No clinical data is submitted in support of this submission."

    Therefore, the document does not contain information about acceptance criteria, a study proving the device meets those criteria, or details regarding sample sizes, ground truth establishment, or expert involvement for clinical performance.

    The submission focuses on demonstrating substantial equivalence through non-clinical testing (bench and simulated use testing, including phantom testing) and comparison of regulatory and technical characteristics with its predicate device (iSR'obot Mona Lisa K111347).

    As such, I cannot create the requested table or answer the specific questions about clinical study details based on the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1