510(k) Data Aggregation

    K Number
    K122967

    Validate with FDA (Live)

    Device Name
    LUCENT
    Date Cleared
    2013-02-21

    (149 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Lucent intervertebral body fusion devices are intended for spinal fusion procedures at one or two contiguous levels (L2-S1) in skeletally mature patients with degenerative disc disease (DDD). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis or retrolisthesis at the involved levels. These patients may have had a previous non-fusion spinal surgery at the involved spinal level(s).

    This device is intended to be used with supplemental spinal fixation systems that have been cleared for use in the lumbosacral spine (i.e., posterior pedicle screw and rod systems, anterior plate systems, and anterior screw and rod systems).

    This device is intended to be used with autogenous bone graft. Patients must have undergone a regimen of at least six (6) months non-operative treatment prior to being treated with this device.

    Device Description

    This product is an intervertebral body fusion device for use in lumbar spinal surgery. It may also be referred to as an interbody device or interbody cage. The device is generally box-shaped with various holes throughout its design to allow for the placement of autograft. The exterior of the device has "teeth" or other generally sharp engagement members on the superior and inferior surfaces to help prevent the device from migrating once it is surgically positioned. The devices may be manufactured from titanium (Ti-6Al-4V) conforming to ASTM F 136 or ISO 5832-3, polyetheretherketone materials conforming to ASTM F 2026 or polyetheretherketone with a plasma sprayed coating of commercially pure titanium (per ASTM F 1580) on their superior and inferior surfaces.

    AI/ML Overview

    I am sorry, but based on the provided text, there is no information about acceptance criteria, device performance in relation to acceptance criteria, sample sizes for test and training sets, data provenance, number or qualifications of experts, adjudication methods, multi-reader multi-case studies, standalone performance, or the ground truth establishment for a medical device.

    The document is a 510(k) summary for a medical device called Lucent®, which is an intervertebral body fusion device. The purpose of this specific 510(k) is for a modification (larger sizes - line addition) to previously cleared devices. The document focuses on:

    • Manufacturer and Contact Information
    • Device Description: Describes the physical characteristics and materials of the Lucent device.
    • Intended Use: Specifies the medical conditions, anatomical locations, and concomitant uses for the device.
    • Performance Data: States that "Static torsion, ASTM F 2077" testing was performed. However, it does not provide the results of this testing or any acceptance criteria.
    • Substantial Equivalence: Asserts that the device is substantially equivalent to predicate devices in stated aspects.
    • FDA Correspondence: Official FDA letter granting clearance.
    • Indications for Use (reiterated).

    The document does not contain the kind of detailed study information you are asking for, which is typically found in full study reports or more comprehensive regulatory submissions.