510(k) Data Aggregation

    K Number
    K121116

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2012-05-08

    (26 days)

    Product Code
    Regulation Number
    888.3080
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The Plateau Spacer System is intended for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) at one or two contiguous levels (L2-S1). DDD is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. DDD patients may also have up to Grade 1 spondylolisthesis at the involved level(s). It is to be used in patients who have had at least six months of non-operative treatment. This device is intended to be used with autogenous bone graft and a supplemental internal spinal fixation system (e.g., pedicle screw or anterolateral plating system) that is cleared for use in the lumbosacral spine.

    Device Description

    The Plateau Spacer System is intended to serve as an intervertebral body fusion device. The implant is available in a range of sizes and footprints to suit the individual pathology and anatomical conditions of the patient. It is fabricated and manufactured from Polyetheretherketone (PEEK-OPTIMA LT1) with tantalum markers. The implant is hollow to permit packing with autogenous bone graft to help promote intervertebral body fusion. The superior and inferior surfaces have teeth to assist in the interface with the vertebral endplates to prevent rotation and/or migration.

    All implants are intended for single use only and should not be reused under any circumstances. Do not use any of the Plateau Spacer System components from any other system or manufacturer. The Plateau Spacer System components should never be reused under any circumstances.

    AI/ML Overview

    This 510(k) summary (K121116) describes the PLATEAU®-X Spacer System, an intervertebral body fusion device. The submission is for a line extension to add a Lateral implant offering.

    1. A table of acceptance criteria and the reported device performance

    Acceptance CriteriaReported Device Performance
    Substantial Equivalence to Predicate Devices (K080411, K071795, K112496) in indications for use, material, and basic design.An engineering analysis was presented to show that the line extension (Lateral implant) does not impose a new worst-case scenario and is therefore substantially equivalent to the predicate devices.

    2. Sample size used for the test set and the data provenance

    The document does not describe a clinical study with a test set of data or participants. The evaluation for substantial equivalence was based on engineering analysis rather than human performance data.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable, as no clinical study involving human readers or a test set requiring expert ground truth was conducted.

    4. Adjudication method for the test set

    Not applicable, as no clinical study involving human readers or a test set was conducted.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This device is an implantable medical device, not an AI-assisted diagnostic tool.

    6. If a standalone (i.e. algorithm only without human-in-the-loop performance) was done

    Not applicable. This device is an implantable medical device, not an algorithm. The "standalone" performance here refers to the device's mechanical and material properties, which were assessed via engineering analysis.

    7. The type of ground truth used

    The "ground truth" in this context is the established safety and effectiveness profile of the predicate devices. The study aimed to demonstrate that the new device (line extension) is substantially equivalent to these predicates, meaning it performs similarly and does not introduce new safety or effectiveness concerns. The method used was an engineering analysis comparing the new design to existing predicates.

    8. The sample size for the training set

    Not applicable, as this is not an AI/algorithm-based device requiring a training set.

    9. How the ground truth for the training set was established

    Not applicable, as this is not an AI/algorithm-based device.