510(k) Data Aggregation

    K Number
    K103724

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-06-08

    (169 days)

    Product Code
    Regulation Number
    892.2050
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The 10MP Grayscale Flat Panel Display (GX1030) is intended to be used in displaying and viewing digital images, including digital mammography, for review and analysis by trained medical practitioners.

    Device Description

    The 6GF6201-8CS## is a diagnostic 10MP gravscale flat panel display for viewing medical images. With the callbrated gamma response stored in five internal lookup tables, the display is suitable for use with a wide range of DV! graphic controller boards. The display is used in dual-head configuration.

    The 10MP Grayscale Flat Panel Display uses a monochrome LCD panel employing in-plane switching (IPS) technology to allow wide viewing angles. It has a resolution of 4096 x 2560 pixels and is used in landscape mode. The display uses backlight sensor to automatically stabilize the set luminance levels of the CCFL backlight over time. It also sports an integrated front sensor for independent grayscale verification. The factory calibrated gamma response is stored in five lookup tables located in the display, allowing users to adapt the display to local lighting conditions and ensuring that the display function is DICOM compliant regardless of the display controller used.

    The 10MP Grayscale Flat Panel Display may be offerent housing colors and with different logos. These cosmetic differences are reflected in the designators represented by the characters "$" and "#" included in the model trade name 6GF6201-8C$#, where $ represents a letter between A and Z, and # is a number between 0 and 9.

    The 10MP Grayscale Flat Panel Display uses the same LCD panel from the same manufactorer as the predicate device and employs CCFL backlight technology. It is equipped with two integrated luminance sensors, one mounted rear center and a built in front sensor, as included with the Coronis Fusion 10MP.

    The housing, stand, electronics and the integrated luminance sensors are not the same as those components used in the predicate devices. The overall design of the 6GF6201-8C$## was validated in accordance with internationally recognized safety and EMC standards by independent testing facilities and inhouse. Additionally, EIZO GmbH performed a range of system and performance tests to ensure that the 10MP Grayscale Flat Panel Display performed in accordance with its specifications.

    While the predicate device is equipped with a proprietary high speed display controller, the 6GF6201-8CS## was designed to receive and display images from standard, commercial DVI display controllers.

    AI/ML Overview

    The provided document is an Abbreviated 510(k) Summary for a medical display device, the EIZO 10MP Grayscale Flat Panel Display (GX1030). It is not a study report for an AI-powered device, but rather a regulatory submission for a display device.

    Therefore, the document does not contain the information required to answer your request about acceptance criteria and a study proving an AI device meets them. Specifically:

    • No AI device: The device described is a medical display, not an AI algorithm.
    • No acceptance criteria for an AI algorithm: The document focuses on the display's technical characteristics and substantial equivalence to a predicate device, not on clinical performance metrics for an AI.
    • No study proving AI device performance: The "tests" mentioned are related to safety, EMC, and display performance (e.g., luminance stability, gamma response), not on the diagnostic accuracy of an AI.
    • No information on sample sizes (test/training sets), experts, adjudication methods, MRMC studies, or ground truth for an AI.

    The document states:

    • "EIZO GmbH performed a range of system and performance tests to ensure that the 10MP Grayscale Flat Panel Display performed in accordance with its specifications."
    • "None of the tests revealed behaviors inconsistent with the expected performance of a 10MP grayscale flat panel display."

    These statements refer to the display's technical performance validation, not a clinical study to evaluate an AI's diagnostic abilities.