Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K082666

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2008-10-15

    (33 days)

    Product Code
    Regulation Number
    878.4400
    Age Range
    All
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The ArthroCare System 12000 is indicated for resection, ablation, and coagulation of soft tissue and hemostasis of blood vessels in arthroscopic and orthopedic procedures:

    Arthroscopic and Orthopedic ProceduresJoint Specific or All Joints (ankle, elbow, hip, knee, shoulder, and wrist)
    Ablation and Debridement
    • ACL/PCLKnee
    • AcromioplastyShoulder
    • Articular CartilageAll Joints
    • BursectomyAll Joints
    • ChondroplastyAll Joints
    • FasciaAll Joints
    • LigamentAll Joints
    • NotchplastyKnee
    • Scar TissueAll Joints
    • Soft TissueAll Joints
    • Subacromial DecompressionShoulder
    • SynovectomyAll Joints
    • TendonAll Joints
    Excision and Resection
    • Acetabular LabrumHip
    • Articular LabrumAll Joints
    • CapsuleAll Joints
    • Capsular ReleaseKnee
    • Cartilage FlapsKnee
    • CystsAll Joints
    • Discoid MeniscusKnee
    • Frozen Shoulder ReleaseShoulder
    • Glenoidale LabrumShoulder
    • Lateral ReleaseKnee
    • LigamentAll Joints
    • Loose BodiesAll Joints
    • Meniscal CystectomyKnee
    • MeniscectomyKnee
    • Plica RemovalAll Joints
    • Scar TissueAll Joints
    • Soft TissueAll Joints
    • Synovial MembraneAll Joints
    • TendonAll Joints
    • Triangular Fibrocartilage (TFCC)Wrist
    • VillusectomyKnee
    Coagulation
    • ACL/PCLKnee
    • Articular CartilageAll Joints
    • Carpal LigamentsWrist
    • Glenohumeral CapsuleShoulder
    • LigamentAll Joints
    • Medial RetinaculumKnee
    • Rotator CuffShoulder
    • TendonAll Joints
    • Wrist TendonsWrist
    Device Description

    The ArthroCare® System 12000 is a bipolar, high frequency, electrosurgical generator called the Controller that is intended to be used with a family of disposable, binolar, single use Wands.

    AI/ML Overview

    This 510(k) summary for the ArthroCare System 12000 does not describe any acceptance criteria or a study that uses a quantitative test set to prove the device meets said criteria.

    The document states:
    "This Special 510(k) proposes a modification in the performance specifications and labeling for the ArthroCare System 12000, which was previously cleared in K071709 on August 7, 2007. The indications for use, technology, principle of operation, materials, packaging, and sterilization parameters of the ArthroCare System 12000 remain the same as in the predicate cleared 510(k). The modified ArthroCare System 12000, as described in this Special 510(k), is substantially equivalent to the predicate device. The proposed modifications in performance specifications and labeling are not substantial changes or modifications, and do not significantly affect the safety or efficacy of the System."

    This indicates that the submission is for a modification to an already cleared device, and the basis for clearance is substantial equivalence to a predicate device (K071709), rather than a new study demonstrating performance against specific acceptance criteria using a test set. Therefore, the requested information regarding acceptance criteria, study details, sample sizes, ground truth establishment, expert involvement, and comparative effectiveness studies is not present in the provided text.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1