510(k) Data Aggregation

    K Number
    K082254

    Validate with FDA (Live)

    Manufacturer
    Date Cleared
    2011-02-07

    (913 days)

    Product Code
    Regulation Number
    870.2770
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    N/A
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    For the purposes of performing a non-invasive BIA measurement on normal healthy human adults and children to determine their Body Composition status.

    The measurements include Body Mass Index (BMI), waist/hip ratio, tissue impedance at 5kHz and at 50kHz. These measurements are used to calculate the estimated levels of body fat, body lean and dry lean, total body water, and metabolic rates,

    Bodystat BODY MANAGER and WELLNESS SOFTWARE PROGRAMS are automatically included with this device.

    The Body Manager Program is designed for when a client returns to be tested in order to track their changes in body composition over a period of time.

    The Wellness Program is designed for first time assessments on subjects. The program's graphical presentations provide information on each of the specific measurements in an educational format.

    Device Description

    The Bodystat 1500MDD Body Composition Monitoring Unit is a light weight, handheld, batteryoperated device that uses bio-electrical impedance analysis (BIA) to measure the impedance of the flow of an electrical current through the body. The impedance of tissue is proportional to the amount of fluid in the tissue; water is low in fat tissues, thus fat tissue has a high impedance, and high in lean tissues, thus lean tissue has a low impedance. The subject's age, sex, height, waist measurement, and hip measurement are also used to calculate various values.

    In practice, a small constant current is passed between electrodes spanning the body and the voltage drop between electrodes provides a measure of impedance. Prediction equations, previously generated by correlating impedance measures against an independent estimate of TBW (total body water), may be used subsequently to convert a measured impedance to a corresponding estimate of TBW. Lean body mass is then calculated from this estimate using an assumed hydration fraction for lean tissue; Bodystat uses a proprietary regression equation for this calculation. Fat mass is calculated as the difference between body weight and lean body mass. A body composition analysis report is comprised of Body Fat, Lean Body Mass, Dry Lean Mass, Total Body Water, and Optimal Ranges. Metabolic rates, Waist/Hip Ratio, and BMI are also reported. In addition, raw values are shown for Impedance at 5 kHz and at 50 kHz. The Bodystat 1500MDD contains separate equations for children aged 6 - 17 years and for adults aged 18 - 70 years.

    AI/ML Overview

    The provided text does NOT include details about acceptance criteria or a study proving the device meets them. The document is a 510(k) summary for the Bodystat 1500MDD Body Composition Monitoring Unit, indicating its substantial equivalence to previously cleared devices. It describes the device, its intended use, and a comparison to predicate devices, but lacks information on performance criteria or a study with specific results.

    Therefore, I cannot populate the table or answer the specific questions about the study from the given input.