510(k) Data Aggregation

    K Number
    K080979

    Validate with FDA (Live)

    Date Cleared
    2008-10-31

    (207 days)

    Product Code
    Regulation Number
    888.3390
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Disposable cement spacer molds with stainless steel reinforcement stems, adaptors and inserts are indicated for use to mold a temporary hemi-hip replacement for skeletally mature patients undergoing a two-stage revision procedure due to a septic process. The temporary prosthesis is assembled and inserted into the femoral medullary canal and acetabular cavity following removal of the existing femoral and acetabular implants and debridement. The device is intended for use in conjunction with systemic antimicrobial antibiotic therapy (standard treatment approach to an infection).

    The StageOne" Select hemi-hip prosthesis is not intended for use more than 180 days, at which time it must be explanted and permanent devices implanted or another appropriate treatment performed (e.g. resection arthroplasty, fusion, etc.)

    Due to the inherent mechanical limitations of the hemi-hip prosthesis material (polymethylmethacrylate/gentamicin), the temporary hemi-hip prosthesis is only indicated for patients who will consistently use traditional mobility assist devices (e.g. crutches, walkers) throughout the implant period.

    Device Description

    Cement Spacer Molds are designed to mold a temporary "spacer" hip implant made of antibiotic impregnated bone cement. The spacers are intended for short-term duration use only, not to exceed 6 months.

    The StageOne" Select Cement Spacer Molds are a series of Cement Spacer Molds designed to provide modularity of sizing between the femoral stem and the femoral head connponents. The molds provide various stem sizes and various head sizes that can be mated to provide the best fit for each patient. The cement spacer molds are made of biomedical grade silicone. The metal reinforcements within the cement spacer molds are made of implant grade stainless steel.

    AI/ML Overview

    The provided document is a 510(k) summary for the StageOne™ Select Cement Spacer Molds for Temporary Hip Replacement. It describes the device, its indications for use, and claims substantial equivalence to legally marketed predicate devices.

    However, the document does not contain information regarding clinical studies, acceptance criteria, sample sizes for test or training sets, ground truth establishment, expert qualifications, or MRMC comparative effectiveness studies because no clinical testing was performed or provided as a basis for substantial equivalence for this device.

    The relevant section states:

    • "Non-Clinical Testing: Cyclic fatigue testing was conducted on the StageOne™ Select components and the predicate StageOne™ components to provide a direct comparison of the subject and predicate components."
    • "Clinical Testing: None provided as a basis for substantial equivalence."

    Therefore, I cannot provide the requested information in the format of a table or answer the specific questions related to clinical trials, as such details are explicitly stated as not being part of the submission for this particular device. The FDA's determination of substantial equivalence was based on non-clinical testing (cyclic fatigue) and comparison to predicate devices, not on human-in-the-loop performance or standalone algorithm performance.