510(k) Data Aggregation

    K Number
    K073197

    Validate with FDA (Live)

    Date Cleared
    2008-08-28

    (289 days)

    Product Code
    Regulation Number
    N/A
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    Silver Antimicrobial Wound Gel is indicated under the medical supervision of a healthcare professional for the management of dry to moderate exuding partial and full thickness wounds such as:

    • . Pressure ulcers
    • Leg ulcers .
    • . Diabetic ulcers
    • . Graft and donor sites
    • . Post-operative surgical wounds
    • . Trauma wounds (dermal lesions, trauma injuries or incisions)
    • 1st and 2nd degree burns .
    • Abrasions and lacerations .
    Device Description

    Silver Antimicrobial Wound Gel is an opaque, amorphous hydrogel containing a high (>80%) water content and hydrophilic polymer chains. This formulation increases the moisture within the wound through water donation which makes the gel effective in assisting the debridement and desloughing process in dry necrotic wounds, whilst maintaining a moist wound environment for optimal wound healing.
    Silver Antimicrobial Wound Gel contains an antimicrobial silver compound (silver carbonate) that is an effective barrier to bacterial penetration by inhibiting the growth of broad spectrum of microorganisms which come into contact with the gel.
    Silver Antimicrobial Wound Gel is available in various sizes, and is supplied in aluminium tubes fitted with screw caps. The tubes will be packed in a cardboard dispenser box, with a product insert.

    AI/ML Overview

    Here's an analysis of the provided text regarding the acceptance criteria and supporting studies for the "Silver Antimicrobial Wound Gel":

    The document does not explicitly state numerical acceptance criteria in a table format for device performance. Instead, it relies on demonstrating substantial equivalence to predicate devices and adherence to established in-vitro and in-vivo testing standards.

    1. Table of Acceptance Criteria and Reported Device Performance

    Given the nature of the submission (a 510(k) for a wound gel), the "acceptance criteria" are more implicitly derived from demonstrating safety, efficacy, and substantial equivalence to existing predicate devices.

    Acceptance Criterion (Implicit)Reported Device Performance
    Antimicrobial Barrier Activity (In-vitro)Effective against Staphylococcus aureus (including MRSA), Staphylococcus epidermidis (including MRSE), Streptoccus pyogenes, Pseudomonas aeruginosa, Escherichia coli, Candida albicans, and Aspergillus niger when they come into contact with the gel. Demonstrated by 7-day log reduction and preservative efficacy test (USP 30 <51>).
    BiocompatibilityDemonstrated to be in compliance with BS EN ISO 10993-1 (Biological Evaluation of Medical Devices). No adverse effects noted in the in-vivo study.
    Wound Closure Rate (In-vivo)No statistically significant differences in the rate of wound closure when compared to a similar hydrogel (without silver) and "Wet to Dry" gauze.
    Wound Site Adherence (In-vivo)Not detected for the device, similar to the comparative Hydrogel, and significantly better than "Wet to Dry" gauze.
    Peri-wound Inflammation/Erythema (In-vivo)Less frequently observed and less severe than in "Wet to Dry gauze" treated wounds, similar to the comparative Hydrogel.
    No Adverse Effects (In-vivo)No adverse effects were noted following the use of the Silver Antimicrobial Wound Gel.
    Manufacturing QualityManufactured according to product specification and Good Manufacturing Practices (GMP). Risk analysis performed and controls implemented.
    Substantial Equivalence to Predicate DevicesThe indication for use, performance testing, and antimicrobial activity are substantially equivalent to "Silver Shield™ Antimicrobial Skin and Wound Gel" (K062212) and "AcryDerm Silver Antimicrobial Wound Gel" (K011994, K070333).

    2. Sample Size Used for the Test Set and Data Provenance

    The document primarily references two types of testing for device performance:

    • In-vitro Testing:

      • Sample Size: Not explicitly stated as a numerical count of "samples" for the antimicrobial tests. It mentions a "seven day log reduction evaluation test and preservative efficacy test in accordance with the requirements of USP 30 <51> (Antimicrobial Effectiveness Testing)." This implies standardized methodology with defined replicates, but not a specific "sample size" in terms of clinical cases.
      • Data Provenance: Not specified, but generally, in-vitro tests are conducted in laboratory settings, likely within the UK or a qualified testing facility.
    • In-vivo Testing (Porcine Study):

      • Sample Size: Not explicitly stated as a number of animals or wounds. The wording describes "an in-vivo porcine study" that assessed dressing performance and compared three treatment arms (Silver Antimicrobial Wound Gel, equivalent Hydrogel without silver, and "Wet to Dry" gauze). We cannot determine the exact sample size from the provided text.
      • Data Provenance: The study was "in-vivo," using porcine subjects, implying a controlled animal study. The country of origin for the study is not mentioned. It is a prospective study as it involved applying the treatments and then assessing outcomes.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications

    • In-vitro Testing: Not applicable in the context of "experts establishing ground truth." The ground truth for antimicrobial efficacy is derived from standardized laboratory tests with defined protocols (e.g., USP 30 <51> requirements).
    • In-vivo Testing (Porcine Study): Not explicitly stated. For animal studies, assessments would typically be performed by trained researchers or veterinary professionals. It does not mention a panel of "experts" in the context of radiologists or similar clinical specialties for establishing ground truth, as this is an animal study evaluating wound healing parameters.

    4. Adjudication Method for the Test Set

    • In-vitro Testing: Not applicable. Results are quantitative measurements from lab tests.
    • In-vivo Testing (Porcine Study): Not specified. The document states "The report findings showed that..." suggesting data collection and analysis, but no explicit adjudication method (like 2+1 or 3+1 consensus) among multiple assessors for qualitative observations is described.

    5. Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not conducted. This type of study typically involves multiple human readers evaluating medical images or cases with and without AI assistance to measure reader improvement. The provided document concerns a wound gel and its performance, not an AI-based diagnostic or assistive device for human readers.

    6. Standalone (Algorithm Only Without Human-in-the-Loop Performance) Study

    No, a standalone study in the context of an algorithm's performance was not conducted. The device is a wound gel, which is a physical product, not a software algorithm. Its performance is intrinsic to its physical and chemical properties and how it interacts with wounds, not through an algorithm operating independently.

    7. Type of Ground Truth Used

    • In-vitro Testing: Ground truth is established by standardized laboratory test results (e.g., log reduction of microbial counts for antimicrobial efficacy, compliance with ISO standards for biocompatibility).
    • In-vivo Testing (Porcine Study): Ground truth is based on direct observation and measurement of wound healing parameters in a controlled animal model. This includes wound closure rate, wound site adherence, peri-wound inflammation/erythema, and general absence of adverse effects.

    8. Sample Size for the Training Set

    Not applicable. This device is a wound care product, not an AI or machine learning algorithm that requires a "training set" of data.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable, as there is no training set for this type of device.