    Intended Use

    The device is intended for medical purposes to provide mobility to persons restricted to a seated position.

    Device Description

    The COMFORT SCOOTER, LY-EW406 is an indoor / outdoor Electric Scooter that is battery operated. It has a base with four-wheeled with a seat. The movement of the Wheelchair is controlled by the rider who uses hand controls located at the top of the steering column. The device can be disassembled for transport and is provided with an onboard battery charger.

    AI/ML Overview

    The Comfort Scooter, LY-EW406, is a motorized three-wheeled vehicle intended for medical purposes to provide mobility to persons restricted to a seated position.

    1. Table of Acceptance Criteria and Reported Device Performance

    Feature/TestAcceptance Criteria (Predicate Device K022369)Reported Device Performance (LY-EW406)
    Permissible Load Weight265 lbs265 lbs
    Electronic ControllerUL CertifiedUL Certified
    Recharge SystemUL CertifiedUL Certified
    Electrical SafetyANSI/RESNA WC/Vol.2-1998, CISPR 11: 1990, EN61000-3-2: 1995, IEC61000-3-3: 1995 standards for electrically powered wheelchairs, controllers, and chargersCompliant with ANSI/RESNA WC/Vol.2-1998, CISPR 11: 1990, EN61000-3-2: 1995, IEC61000-3-3: 1995
    Max Speed4.0 mph (predicate)4.2 mph
    Intended UseTo provide mobility to persons restricted to a seated positionTo provide mobility to persons restricted to a seated position

    2. Sample Size Used for the Test Set and Data Provenance

    The submission does not detail a "test set" in the context of clinical data or comparative performance against a predefined set of cases/patients. The performance testing referenced is against engineering standards and comparison to a predicate device.
    Data provenance: Taiwan, R.O.C. (Manufacturer location). The nature of the testing suggests it is primarily engineering/bench testing rather than clinical data, therefore it would be considered prospective for the device under test.

    3. Number of Experts Used to Establish the Ground Truth for the Test Set and Their Qualifications

    Not applicable. The study does not involve human expert interpretation of data for ground truth establishment. The "ground truth" for this device's performance is compliance with established electrical and wheelchair performance standards, and comparison of specifications to a legally marketed predicate device.

    4. Adjudication Method for the Test Set

    Not applicable. This type of adjudication method is usually for clinical studies with expert reviewers, which is not relevant for this device's submission.

    5. If a Multi-Reader Multi-Case (MRMC) Comparative Effectiveness Study Was Done, and Effect Size

    No, a Multi-Reader Multi-Case (MRMC) comparative effectiveness study was not done. This type of study is relevant for diagnostic or screening devices involving human interpretation of medical images or data. The Comfort Scooter is a mobility device; its performance is evaluated against engineering standards and functional specifications rather than clinical diagnostic accuracy.

    6. If a Standalone (i.e., algorithm only without human-in-the-loop performance) Was Done

    Not applicable. This device is a physical product (electric scooter), not an algorithm or AI system. Its performance evaluation is based on direct measurements and adherence to specified standards.

    7. The Type of Ground Truth Used

    The "ground truth" used for this device's acceptance is based on:

    • Engineering Standards: Compliance with recognized international and national standards for electrically powered wheelchairs and electrical safety (e.g., ANSI/RESNA WC/Vol.2-1998, CISPR 11, EN61000-3-2, IEC61000-3-3).
    • Predicate Device Specifications: Direct comparison of key performance characteristics (e.g., load capacity, controller type, recharge system, maximum speed) to a legally marketed device (COMFORT AGILE SCOOTER LY-EW303, K022369) to establish substantial equivalence.

    8. The Sample Size for the Training Set

    Not applicable. There is no training set in the context of machine learning or AI for this device.

    9. How the Ground Truth for the Training Set Was Established

    Not applicable. No training set was used.