Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K052187

    Validate with FDA (Live)

    Date Cleared
    2005-08-22

    (11 days)

    Product Code
    Regulation Number
    888.3070
    Reference & Predicate Devices
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The CD HORIZON® Spinal System is intended for posterior, non-cervical fixation for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis; and/or failed previous fusion.

    When used in a percutaneous, non-cervical, posterior approach with the SEXTANT instrumentation, the CD HORIZON® screws are intended for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis and/or lordosis); tumor; pseudoarthrosis; and/or failed previous fusion.

    Except for hooks, when used as an anterolateral thoracic/lumbar system, CD HORIZON® components such as ECLIPSE® components are intended for the following indications: (1) degenerative disc disease (as defined by back pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), (2) spinal stenosis, (3) spondylolisthesis, (4) spinal deformities (i.e., scoliosis, kyphosis, and/or lordosis), (5) fracture, (6) pseudarthrosis, (7) tumor resection, and/or (8) failed previous fusion.

    The CD HORIZON® SPIRE Plate is posterior, non-pedicle supplemental fixation device, intended for use in the non-cervical spine (T1 – S1). It is intended for plate fixation/attachment to spinous process for the purpose of achieving supplemental fusion in the following conditions: degenerative disc disease - defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies; spondylolisthesis; trauma (i.e., fracture or dislocation); and/or tumor.

    The CD HORIZON® LEGACY 3.5mm rod and associated components, when used as a pedicle screw fixation system of the non-cervical posterior spine in skeletally mature patients, are indicated for one or more of the following: (1) degenerative spondylolisthesis with objective evidence of neurologic impairment, (2) fracture, (3) dislocation, (4) scoliosis, (5) kyphosis, (6) spinal tumor, and/or (7) failed previous fusion (pseudarthrosis).

    In addition, when used as a pedicle screw fixation system, the CD HORIZON® LEGACY 3.5mm rod and associated components, are indicated for skeletally mature patients: (a) having severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar-first sacral (L5-S1) vertebral joint; (b) who are receiving fusions using autogenous bone graft only; (c) who are having the device fixed or attached to the lumbar and sacral spine (L3 and below); and (d) who are having the device removed after the development of a solid fusion mass.

    When used as a pedicle screw system in skeletally mature patients, the CD HORIZON® Spinal System PEEK rods and associated components are intended to provided immobilization and stabilization of spinal segments as an adjunct to fusion in the treatment of the following acute and chronic instabilities of the thoracic, lumbar and sacral spine: (1) degenerative spondylolisthesis with objective evidence of neurologic impairment, (2) kyphosis, and/or (3) failed previous fusion. Additionally, when used as a pedicle screw device, the CD HORIZON® Spinal System PEEK rod constructs are indicated for use in patients who: (1) are receiving fusion with autogenous graft only, (2) who are having the device attached to the lumbar or sacral spine, and/or (3) who are having the device removed after the development of a solid fusion mass.

    In order to achieve additional levels of fixation, the CD HORIZON® Spinal System rods may be connected to the VERTEX™ Reconstruction System with the VERTEX™ rod connector. Refer to the VERTEX™ Reconstruction System Package Insert for a list of the VERTEX™ indications of use.

    Device Description

    The CD HORIZON® Spinal System consists of a variety of rods, hooks, screws, CROSSLINK® plates, staples, and other connecting components used to build a spinal construct. Instrumentation is also available to facilitate implantation of the device components.

    The CD HORIZON® Spinal System is intended to help provide immobilization and stabilization of spinal segments as an adjunct to fusion of the thoracic, lumbar, and/or sacral spine. The CD HORIZON® Spinal System implant components can be rigidly locked into a variety of configurations, with each construct being tailor-made for the individual case. If necessary, the CD HORIZON® Spinal System can be connected to the VERTEX™ Reconstruction System through a rod connector.

    Certain implant components from other Medtronic Sofamor Danck spinal systems can be used with the CD HORIZON® Spinal System. These components include TSRH® rods, hooks, screws, plates, CROSSLINK® plates, connectors, staples and washers; GDLH® rods, hooks, connectors and CROSSLINK® bar and connectors; LIBERTY® rods and screws; DYNALOK PLUS® bolts; and Medtronic Sofamor Danek Multi-Axial rods and screws.

    CD HORIZON® hooks are intended for posterior use only. CD HORIZON® staples and CD HORIZON® ECLIPSE® rods and screws are intended for anterior use only. However, for patients of smaller stature, CD HORIZON® 4.5mm rods and associated components may be used posteriorly.

    The purpose of this 510(k) submission is to include modified CD HORIZON® set screws to the CD HORIZON® Spinal System.

    AI/ML Overview

    The provided text describes a 510(k) premarket notification for the CD HORIZON® Spinal System, focusing on the inclusion of modified set screws. A 510(k) submission generally aims to demonstrate substantial equivalence to a legally marketed predicate device, rather than proving device performance against specific acceptance criteria through a clinical study with detailed statistical endpoints.

    Based on the provided document, the following points can be extracted:

    1. Table of Acceptance Criteria and Reported Device Performance:

    • Acceptance Criteria: The document does not explicitly state quantitative acceptance criteria for device performance (e.g., strength, durability, biocompatibility in a numerical format). Instead, the primary "acceptance criterion" for a 510(k) submission is demonstrating substantial equivalence to existing predicate devices.
    • Reported Device Performance: The document states that "Documentation, including a risk analysis, was provided which demonstrated the subject set screws to be substantially equivalent to predicate CD HORIZON® Spinal System set screws previously cleared..."

    Essentially, the performance metric being assessed is "substantial equivalence," and the reported device performance is that this equivalence was successfully demonstrated.

    2. Sample Size Used for the Test Set and Data Provenance:

    The document does not describe a clinical "test set" in the context of a prospective human study to evaluate the performance of the modified set screws. The 510(k) process for a device like this often relies on engineering testing (e.g., mechanical tests) and comparison to existing data for predicate devices. Therefore, information on sample size for a clinical test set or data provenance (country, retrospective/prospective) is not applicable here as a standalone performance study as typically understood for new device effectiveness was not conducted.

    3. Number of Experts Used to Establish Ground Truth for the Test Set and Qualifications:

    Since a clinical test set with human subject data and corresponding ground truth determination is not described, this section is not applicable.

    4. Adjudication Method for the Test Set:

    Not applicable, as no clinical test set requiring expert adjudication is described in the provided text.

    5. If a Multi Reader Multi Case (MRMC) Comparative Effectiveness Study was done:

    No, a multi-reader multi-case comparative effectiveness study was not done. This type of study is typically used to assess the impact of an AI algorithm on human readers' performance, which is not relevant to this 510(k) submission for mechanical spinal implants.

    6. If a Standalone (algorithm only without human-in-the loop performance) was done:

    No, a standalone algorithm performance study was not done. This device is a mechanical spinal implant, not an algorithm.

    7. The Type of Ground Truth Used:

    For a 510(k) submission based on substantial equivalence for a mechanical device like this, the "ground truth" implicitly refers to the established safety and effectiveness profile of the predicate devices. The demonstration of substantial equivalence relies on comparing the new device's design, materials, and intended use to those of legally marketed predicate devices, supported by engineering tests and risk analysis rather than a "ground truth" derived from patient outcomes in a new study.

    8. The Sample Size for the Training Set:

    Not applicable, as this is a mechanical device submission, not an AI or algorithm-based device that would require a "training set."

    9. How the Ground Truth for the Training Set was Established:

    Not applicable, for the same reasons as point 8.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1