Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K040503

    Validate with FDA (Live)

    Date Cleared
    2004-03-16

    (18 days)

    Product Code
    Regulation Number
    878.4460
    Age Range
    All
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticPediatricDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    The surgeon's glove is a device made of synthetic rubber latex intended to be worn by surgeons and/or operating room personnel to protect a surgical wound from contamination.

    Device Description

    The Powder Free, Polymer Coated Polyisoprene Surgical Gloves, Sterile, Coated with Aloe Vera, Natural colour or Turquoise (Blue/Green) colour are made of synthetic rubber lates intended to be worn by surgeons and/or operating room personnel to protect a surgical wound from contamination.

    AI/ML Overview

    The provided document describes the acceptance criteria and performance of Powder Free, Polymer Coated Polyisoprene Surgical Gloves, Sterile, Coated with Aloe Vera, Natural colour or Turquoise (Blue/Green) colour. The study detailed is aimed at demonstrating substantial equivalence to a legally marketed predicate device (K032942) for 510(k) clearance.

    Here's a breakdown of the requested information based on the provided text:

    1. Table of Acceptance Criteria and Reported Device Performance

    CharacteristicAcceptance Criteria (Standards)Reported Device Performance
    DimensionsASTM D 3577 - 01aE2Meets
    Physical PropertiesASTM D 3577 - 01aE2Meets
    Freedom from pinholesASTM D 3577 - 01aE2 & FDA 21 CFR 800.20Meets
    Powder ResidualASTM D 6124 - 01Meets (< 2 mg/glove)
    BiocompatibilityPrimary Skin Irritation in Rabbits (Test)Passes (Not a primary skin irritant)
    Dermal Sensitization (Test)Passes (Not a contact sensitizer)

    2. Sample size used for the test set and the data provenance

    The document does not explicitly state the sample sizes used for testing each characteristic. It refers to compliance with ASTM standards, which would typically specify sample sizes for testing.

    The data provenance is not explicitly mentioned, but the manufacturer is WRP Asia Pacific Sdn Bhd, located in Malaysia. The testing was conducted to meet US FDA regulations (21 CFR 800.20) and ASTM standards.

    3. Number of experts used to establish the ground truth for the test set and the qualifications of those experts

    Not applicable. This device is a surgical glove, and its performance is evaluated against engineering and biological standards, not against interpretation by medical experts.

    4. Adjudication method for the test set

    Not applicable. As described above, performance is evaluated against objective standards.

    5. If a multi-reader multi-case (MRMC) comparative effectiveness study was done, If so, what was the effect size of how much human readers improve with AI vs without AI assistance

    Not applicable. This is not an AI-assisted diagnostic device.

    6. If a standalone (i.e., algorithm only without human-in-the-loop performance) was done

    Not applicable. This is not a software algorithm.

    7. The type of ground truth used

    The ground truth is established by objective engineering and biological standards and test methods.

    • Engineering Standards: ASTM D 3577 - 01aE2 for dimensions, physical properties, and freedom from pinholes; ASTM D 6124 - 01 for powder residual.
    • Regulatory Standard: FDA 21 CFR 800.20 for freedom from pinholes.
    • Biological Testing: Primary Skin Irritation in Rabbits and Dermal Sensitization tests for biocompatibility.

    8. The sample size for the training set

    Not applicable. There is no training set for this type of device (surgical glove).

    9. How the ground truth for the training set was established

    Not applicable. There is no training set.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1