Search Filters

Search Results

Found 1 results

510(k) Data Aggregation

    K Number
    K031073

    Validate with FDA (Live)

    Date Cleared
    2003-11-05

    (215 days)

    Product Code
    Regulation Number
    872.3930
    Panel
    Dental
    Reference & Predicate Devices
    Predicate For
    AI/MLSaMDIVD (In Vitro Diagnostic)TherapeuticDiagnosticis PCCP AuthorizedThirdpartyExpeditedreview
    Intended Use

    PerioGlas Plus - Settable Bone Graft Substitute is indicated only for bony voids or gaps that are not intrinsic to the stability of the bony structure. PerioGlas Plus is indicated to be packed into bony voids or gaps to fill and/or augment dental intraosseous, oral and maxillofacial defects. These defects may be surgically created osseous defects or osseous defects created from traumatic injury to the bone, including: periodontal/infrabony defects; alveolar ridge augmentation (sinusotomy, osteotomy, cystectomy); dental extraction sites (ridge maintenance, implant preparation/placement); craniofacial augmentation; sinus lifts; cystic defects. The product provides a bone void filler that resorbs and is replaced with bone during the healing process.

    Device Description

    PerioGlas Plus is a synthetic resorbable osteoconductive bone graft substitute composed of a calcium phospho-silicate material and a calcium sulfate binder. The device is intended for dental intraosseous, oral, and maxillofacial bony defects. The inorganic calcium and phosphorous components are thermally incorporated in a sodium silicate network (PerioGlas) designed specifically for its absorbability and osteoconductive nature. The calcium sulfate component binds the PerioGlas particles together at the time of implantation and is absorbed from the graft site over the first several weeks following implantation. On absorption of the calcium sulfate, the PerioGlas particles remain in the graft site and are progressively aborbed and replaced by host bone during the healing process.

    AI/ML Overview

    The provided document is a 510(k) Premarket Notification for the PerioGlas® Plus - Settable Bone Graft Substitute. It does not include information about acceptance criteria or a study proving the device meets those criteria in the context of diagnostic performance (as would be typical for an AI/CADe device).

    Instead, this document describes a medical device, its intended use, technological characteristics, and claims substantial equivalence to predicate devices based on its composition and mechanism of action for bone regeneration. The "studies" mentioned are in vitro dissolution data and summaries of prior in vivo performance data for its components, which are used to support the substantial equivalence claim, not to measure against specific performance metrics for a diagnostic device.

    Therefore, I cannot populate the table or answer the subsequent questions as they pertain to a type of data (acceptance criteria for diagnostic performance, sample sizes for test/training sets, expert adjudication, MRMC studies, standalone performance, etc.) that is not present in this regulatory submission for a bone graft substitute.

    The document does not contain the information required to answer your questions regarding acceptance criteria and performance studies for a diagnostic device.

    Ask a Question

    Ask a specific question about this device

    Page 1 of 1